{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T06:34:05Z","timestamp":1784615645314,"version":"3.55.0"},"reference-count":18,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T00:00:00Z","timestamp":1685577600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T00:00:00Z","timestamp":1685577600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Foot and Ankle Surgery"],"published-print":{"date-parts":[[2023,6]]},"DOI":"10.1016\/j.fas.2023.04.008","type":"journal-article","created":{"date-parts":[[2023,4,25]],"date-time":"2023-04-25T20:24:48Z","timestamp":1682454288000},"page":"324-328","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"title":["Angle bisector method to determine the accurate angle for tibiofibular syndesmotic fixation: A validation study with 3D-printed anatomical models"],"prefix":"10.1016","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4565-6383","authenticated-orcid":false,"given":"Bedri","family":"Karaismailoglu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davut","family":"Yerlikaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ceren","family":"Ozdemir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kubra","family":"Dalbudak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tolga Barkan","family":"Komurcu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Musa Batuhan","family":"Yolcu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arin","family":"Celayir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.fas.2023.04.008_bib1","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1177\/107110070602701005","article-title":"Malreduction of the tibiofibular syndesmosis in ankle fractures","volume":"27","author":"Gardner","year":"2006","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.fas.2023.04.008_bib2","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1097\/00005131-200502000-00006","article-title":"Predictors of functional outcome following transsyndesmotic screw fixation of ankle fractures","volume":"19","author":"Weening","year":"2005","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.fas.2023.04.008_bib3","first-page":"311","article-title":"Fractures of the ankle and the distal part of the tibia","volume":"46","author":"Vander Griend","year":"1997","journal-title":"Instr Course Lect"},{"issue":"94","key":"10.1016\/j.fas.2023.04.008_bib4","doi-asserted-by":"crossref","first-page":"2256","DOI":"10.2106\/JBJS.K.01726","article-title":"Forceps reduction of the syndesmosis in rotational ankle fractures","volume":"Vol","author":"Phisitkul","year":"2012","journal-title":"J Bone Jt Surg-Am"},{"key":"10.1016\/j.fas.2023.04.008_bib5","unstructured":"D M Hahn, C L Colton , 2007. Malleolar fractures. AO Princ. Fract. Manag. 2nd Ed, 2007, p. 870\u2013896."},{"key":"10.1016\/j.fas.2023.04.008_bib6","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.foot.2014.07.001","article-title":"A computed tomography evaluation of two hundred normal ankles, to ascertain what anatomical landmarks to use when compressing or placing an ankle syndesmosis screw","volume":"24","author":"Kennedy","year":"2014","journal-title":"Foot"},{"key":"10.1016\/j.fas.2023.04.008_bib7","doi-asserted-by":"crossref","DOI":"10.1053\/j.jfas.2023.04.001","article-title":"Cortices of fibula and tibia can provide landmarks for accurate syndesmosis fixation angle: Computed tomography validation of angle bisector method","author":"Karaismailo\u011flu","year":"2023","journal-title":"J Foot Ankle Surg"},{"key":"10.1016\/j.fas.2023.04.008_bib8","doi-asserted-by":"crossref","first-page":"1331","DOI":"10.1002\/sim.1108","article-title":"Sample size requirements for estimating intraclass correlations with desired precision","volume":"21","author":"Bonett","year":"2002","journal-title":"Stat Med"},{"key":"10.1016\/j.fas.2023.04.008_bib9","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1053\/j.jfas.2020.07.003","article-title":"Ideal angle of upper and lower syndesmotic fixation based on weightbearing computed tomographic imaging in uninjured ankles","volume":"59","author":"Boffeli","year":"2020","journal-title":"J Foot Ankle Surg"},{"key":"10.1016\/j.fas.2023.04.008_bib10","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1053\/j.jfas.2019.05.005","article-title":"Optimal screw fixation of syndesmosis using a targeting drill guide: a technical note","volume":"59","author":"Lee","year":"2020","journal-title":"J Foot Ankle Surg"},{"key":"10.1016\/j.fas.2023.04.008_bib11","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1016\/j.jcot.2019.09.015","article-title":"Malleolar tips as reference points for positioning of syndesmotic screw: a preliminary CT based analysis","volume":"11","author":"Kumar","year":"2020","journal-title":"J Clin Orthop Trauma"},{"key":"10.1016\/j.fas.2023.04.008_bib12","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1053\/j.jfas.2017.05.040","article-title":"Comparison of clamp reduction and manual reduction of syndesmosis in rotational ankle fractures: a prospective randomized trial","volume":"57","author":"Park","year":"2018","journal-title":"J Foot Ankle Surg"},{"key":"10.1016\/j.fas.2023.04.008_bib13","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1016\/j.injury.2017.01.029","article-title":"Simulating clamp placement across the trans-syndesmotic angle of the ankle to minimize malreduction: a radiological study","volume":"48","author":"Putnam","year":"2017","journal-title":"Injury"},{"key":"10.1016\/j.fas.2023.04.008_bib14","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1016\/j.fas.2021.10.003","article-title":"The use of intraoperative comparative fluoroscopy allows for assessing sagittal reduction and predicting syndesmosis reduction in ankle fractures","volume":"28","author":"Abarca","year":"2022","journal-title":"Foot Ankle Surg"},{"key":"10.1016\/j.fas.2023.04.008_bib15","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1097\/BOT.0000000000000882","article-title":"Medial clamp tine positioning affects ankle syndesmosis malreduction","volume":"31","author":"Cosgrove","year":"2017","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.fas.2023.04.008_bib16","doi-asserted-by":"crossref","DOI":"10.1177\/2325967118804204","article-title":"Biomechanical comparison of 3 syndesmosis repair techniques with suture button implants","volume":"6","author":"Parker","year":"2018","journal-title":"Orthop J Sport Med"},{"key":"10.1016\/j.fas.2023.04.008_bib17","first-page":"9","article-title":"3D printing experimental validation of the finite element analysis of the maxillofacial model","author":"Shu","year":"2021","journal-title":"Front Bioeng Biotechnol"},{"key":"10.1016\/j.fas.2023.04.008_bib18","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1007\/s00068-018-0970-3","article-title":"Validation study of 3D-printed anatomical models using 2 PLA printers for preoperative planning in trauma surgery, a human cadaver study","volume":"45","author":"Brouwers","year":"2019","journal-title":"Eur J Trauma Emerg Surg"}],"container-title":["Foot and Ankle Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1268773123000772?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1268773123000772?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T11:10:50Z","timestamp":1761131450000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1268773123000772"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,6]]}},"alternative-id":["S1268773123000772"],"URL":"https:\/\/doi.org\/10.1016\/j.fas.2023.04.008","relation":{},"ISSN":["1268-7731"],"issn-type":[{"value":"1268-7731","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Angle bisector method to determine the accurate angle for tibiofibular syndesmotic fixation: A validation study with 3D-printed anatomical models","name":"articletitle","label":"Article Title"},{"value":"Foot and Ankle Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.fas.2023.04.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}