{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T02:22:52Z","timestamp":1791944572095,"version":"4.3.4"},"reference-count":30,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Foot and Ankle Surgery"],"published-print":{"date-parts":[[2025,12]]},"DOI":"10.1016\/j.fas.2025.05.005","type":"journal-article","created":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T19:13:21Z","timestamp":1747163601000},"page":"684-694","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["A systematic review of biomechanical studies utilising finite element analysis in hallux valgus deformity"],"prefix":"10.1016","volume":"31","author":[{"given":"R.","family":"Geleit","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Nunes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Lam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Ray","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.F.","family":"Ferreira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.L.","family":"Lewis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.fas.2025.05.005_bib1","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1186\/s13047-023-00661-9","article-title":"Global prevalence and incidence of hallux valgus: a systematic review and meta-analysis","volume":"16","author":"Cai","year":"2023","journal-title":"J Foot Ankle Res"},{"key":"10.1016\/j.fas.2025.05.005_bib2","first-page":"619","article-title":"Solution of Problems of Elasticity by the Frame-Work Method","author":"Hrennikoff","year":"1941","journal-title":"J Appl Mech"},{"issue":"6","key":"10.1016\/j.fas.2025.05.005_bib3","doi-asserted-by":"crossref","first-page":"4431","DOI":"10.1007\/s11831-022-09740-9","article-title":"Eighty years of the finite element method: Birth, evolution, and future","volume":"29","author":"Liu","year":"2022","journal-title":"Arch Comput Methods Eng"},{"issue":"4","key":"10.1016\/j.fas.2025.05.005_bib4","first-page":"571","article-title":"Basilar crescentic osteotomy. A three-dimensional computer simulation","volume":"20","author":"Kay","year":"1989","journal-title":"Orthop Clin North Am"},{"issue":"11","key":"10.1016\/j.fas.2025.05.005_bib5","doi-asserted-by":"crossref","first-page":"2794","DOI":"10.1111\/os.13862","article-title":"Finite element parametric design of hallux Valgus orthosis based on orthogonal analysis","volume":"15","author":"Tang","year":"2023","journal-title":"Orthop Surg"},{"issue":"12","key":"10.1016\/j.fas.2025.05.005_bib6","doi-asserted-by":"crossref","first-page":"3243","DOI":"10.1111\/os.13903","article-title":"Biomechanical comparison between rotational Scarf osteotomy and translational Scarf osteotomy: A finite element analysis","volume":"15","author":"Li","year":"2023","journal-title":"Orthop Surg"},{"key":"10.1016\/j.fas.2025.05.005_bib7","doi-asserted-by":"crossref","DOI":"10.3389\/fbioe.2024.1415617","article-title":"Stability of osteotomy in minimally invasive hallux valgus surgery with \u201c8\u201d shaped bandage during gait: a finite element analysis","volume":"12","author":"Sun","year":"2024","journal-title":"Front Bioeng Biotechnol"},{"issue":"1","key":"10.1016\/j.fas.2025.05.005_bib8","doi-asserted-by":"crossref","first-page":"127","DOI":"10.3390\/biology11010127","article-title":"Effect of displacement degree of distal chevron osteotomy on metatarsal stress: a finite element method","volume":"11","author":"Zhang","year":"2022","journal-title":"Biology"},{"key":"10.1016\/j.fas.2025.05.005_bib9","doi-asserted-by":"crossref","first-page":"n160","DOI":"10.1136\/bmj.n160","article-title":"PRISMA 2020 explanation and elaboration: updated guidance and exemplars for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"issue":"15","key":"10.1016\/j.fas.2025.05.005_bib10","doi-asserted-by":"crossref","first-page":"1822","DOI":"10.1080\/10255842.2022.2148465","article-title":"Development and validation of risk of bias tool for the use of finite element analysis in dentistry (ROBFEAD)","volume":"26","author":"Mathur","year":"2023","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"2","key":"10.1016\/j.fas.2025.05.005_bib11","first-page":"234","article-title":"Mitchell\u2019s osteotomy augmented with bio-absorbable pins for the treatment of hallux valgus: A comparative finite element study","volume":"19","author":"Brilakis","year":"2019","journal-title":"J Musculoskelet Neuron Inter"},{"issue":"1","key":"10.1016\/j.fas.2025.05.005_bib12","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1186\/s12891-019-2973-6","article-title":"Impact of first metatarsal shortening on forefoot loading pattern: a finite element model study","volume":"20","author":"Geng","year":"2019","journal-title":"BMC Musculoskelet Disord"},{"key":"10.1016\/j.fas.2025.05.005_bib13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.clinbiomech.2018.06.002","article-title":"Biomechanical evaluation of the first ray in pre-\/post-operative hallux valgus: A comparative study","volume":"60","author":"Guo","year":"2018","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"10.1016\/j.fas.2025.05.005_bib14","first-page":"2946","article-title":"Primary analysis of the first ray using a 3-dimension finite element foot model","volume":"2005","author":"Kai","year":"2005","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"issue":"2","key":"10.1016\/j.fas.2025.05.005_bib15","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.fas.2024.09.001","article-title":"Comparative biomechanical study of different screw fixation methods for minimally invasive hallux valgus surgery: A finite element analysis","volume":"31","author":"Lewis","year":"2025","journal-title":"Foot Ankle Surg"},{"issue":"3","key":"10.1016\/j.fas.2025.05.005_bib16","doi-asserted-by":"crossref","DOI":"10.1177\/10225536221143816","article-title":"Modified scarf osteotomy for hallux valgus: From a finite element model to clinical results","volume":"30","author":"Li","year":"2022","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"10.1016\/j.fas.2025.05.005_bib17","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.medengphy.2017.04.010","article-title":"Biomechanical study on surgical fixation methods for minimally invasive treatment of hallux valgus","volume":"46","author":"Mao","year":"2017","journal-title":"Med Eng Phys"},{"issue":"1","key":"10.1016\/j.fas.2025.05.005_bib18","doi-asserted-by":"crossref","first-page":"152","DOI":"10.2174\/1874325001004010152","article-title":"Ninety-degree chevron osteotomy for correction of hallux valgus deformity: clinical data and finite element analysis","volume":"4","author":"Matzaroglou","year":"2010","journal-title":"Open Orthop J"},{"issue":"7","key":"10.1016\/j.fas.2025.05.005_bib19","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1007\/s11517-015-1260-4","article-title":"Influence of first proximal phalanx geometry on hallux valgus deformity: a finite element analysis","volume":"53","author":"Morales-Orcajo","year":"2015","journal-title":"Med Biol Eng Comput"},{"issue":"c","key":"10.1016\/j.fas.2025.05.005_bib20","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.jmbbm.2013.08.030","article-title":"Patient-specific FE analyses of metatarsal bones with inhomogeneous isotropic material properties","volume":"29","author":"Trabelsi","year":"2014","journal-title":"J Mech Behav Biomed Mater"},{"issue":"12","key":"10.1016\/j.fas.2025.05.005_bib21","doi-asserted-by":"crossref","first-page":"3142","DOI":"10.1016\/j.jbiomech.2015.07.013","article-title":"Functional restoration and risk of non-union of the first metatarsocuneiform arthrodesis for hallux valgus: A finite element approach","volume":"48","author":"Wai-Chi Wong","year":"2015","journal-title":"J Biomech"},{"issue":"8","key":"10.1016\/j.fas.2025.05.005_bib22","article-title":"Finite element analysis of generalized ligament laxity on the deterioration of hallux Valgus deformity (bunion)","volume":"8","author":"Wong","year":"2020","journal-title":"Front Bioeng Biotechnol"},{"issue":"110941","key":"10.1016\/j.fas.2025.05.005_bib23","article-title":"Evaluating function in the hallux valgus foot following a 12-week minimalist footwear intervention: A pilot computational analysis","volume":"132","author":"Xiang","year":"2022","journal-title":"J Biomech"},{"issue":"2","key":"10.1016\/j.fas.2025.05.005_bib24","doi-asserted-by":"crossref","DOI":"10.1177\/10225536231175235","article-title":"Three dimensional finite element analysis of biomechanics of osteotomy ends with three different fixation methods after hallux valgus minimally invasive osteotomy","volume":"31","author":"Xie","year":"2023","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"10.1016\/j.fas.2025.05.005_bib25","doi-asserted-by":"crossref","first-page":"648","DOI":"10.3389\/fbioe.2020.00648","article-title":"The role of footwear in the pathogenesis of hallux Valgus: A proof-of-concept finite element analysis in recent humans and Homo naledi","volume":"8","author":"Yu","year":"2020","journal-title":"Front Bioeng Biotechnol"},{"key":"10.1016\/j.fas.2025.05.005_bib26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.compbiomed.2018.04.010","article-title":"Effects of severe hallux valgus on metatarsal stress and the metatarsophalangeal loading during balanced standing: A finite element analysis","volume":"97","author":"Zhang","year":"2018","journal-title":"Comput Biol Med"},{"issue":"0","key":"10.1016\/j.fas.2025.05.005_bib27","first-page":"1","article-title":"Biomechanical model of minimally invasive hallux valgus surgery","volume":"0","author":"Zhang","year":"2024","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"4","key":"10.1016\/j.fas.2025.05.005_bib28","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/j.fas.2021.07.013","article-title":"The impact of hallux valgus on function and quality of life in females","volume":"28","author":"Lewis","year":"2022","journal-title":"Foot Ankle Surg"},{"issue":"1","key":"10.1016\/j.fas.2025.05.005_bib29","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1186\/s13018-017-0622-z","article-title":"Loading pattern of postoperative hallux valgus feet with and without transfer metatarsalgia: a case control study","volume":"12","author":"Geng","year":"2017","journal-title":"J Orthop Surg Res"},{"issue":"8","key":"10.1016\/j.fas.2025.05.005_bib30","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2020-047273","article-title":"Hallux valgus orthosis characteristics and effectiveness: a systematic review with meta-analysis","volume":"11","author":"Kwan","year":"2021","journal-title":"BMJ Open"}],"container-title":["Foot and Ankle Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1268773125001213?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1268773125001213?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T01:17:48Z","timestamp":1763601468000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1268773125001213"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":30,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["S1268773125001213"],"URL":"https:\/\/doi.org\/10.1016\/j.fas.2025.05.005","relation":{},"ISSN":["1268-7731"],"issn-type":[{"value":"1268-7731","type":"print"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A systematic review of biomechanical studies utilising finite element analysis in hallux valgus deformity","name":"articletitle","label":"Article Title"},{"value":"Foot and Ankle Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.fas.2025.05.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 European Foot and Ankle Society. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}