{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T17:57:09Z","timestamp":1786989429938,"version":"build-2736575974"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,6,1]],"date-time":"2018-06-01T00:00:00Z","timestamp":1527811200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,6,1]],"date-time":"2018-06-01T00:00:00Z","timestamp":1527811200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100000848","name":"University of Edinburgh","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100000848","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Foot"],"published-print":{"date-parts":[[2018,6]]},"DOI":"10.1016\/j.foot.2018.02.002","type":"journal-article","created":{"date-parts":[[2018,2,19]],"date-time":"2018-02-19T12:29:09Z","timestamp":1519043349000},"page":"63-69","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"special_numbering":"C","title":["Measurement of temperature induced in bone during drilling in minimally invasive foot surgery"],"prefix":"10.1016","volume":"35","author":[{"given":"Noor Azzizah","family":"Omar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John C.","family":"McKinley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.foot.2018.02.002_bib0005","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1016\/j.medengphy.2011.05.013","article-title":"Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: an in vitro study","volume":"33","author":"Karaca","year":"2011","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.foot.2018.02.002_bib0010","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.clinbiomech.2011.10.010","article-title":"Cortical bone drilling and thermal necrosis","volume":"27","author":"Augustin","year":"2012","journal-title":"Clin Biomech"},{"issue":"4","key":"10.1016\/j.foot.2018.02.002_bib0015","doi-asserted-by":"crossref","first-page":"208","DOI":"10.5435\/00124635-200704000-00004","article-title":"Osteonecrosis in the foot","volume":"15","author":"Digiovanni","year":"2007","journal-title":"J Am Acad Orthopaed Surg"},{"issue":"1","key":"10.1016\/j.foot.2018.02.002_bib0020","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/0022-3913(83)90174-9","article-title":"Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit","volume":"50","author":"Eriksson","year":"1983","journal-title":"J Prosthet Dent"},{"key":"10.1016\/j.foot.2018.02.002_bib0025","first-page":"447","article-title":"Bone blood flow response to surgical trauma","volume":"33","author":"Field","year":"2002","journal-title":"Int J Care Inj"},{"key":"10.1016\/j.foot.2018.02.002_bib0030","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1016\/0278-2391(84)90417-8","article-title":"The effect of heat on bone regeneration using the bone growth chamber","volume":"42","author":"Eriksson","year":"1984","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.foot.2018.02.002_bib0035","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/s00402-007-0427-3","article-title":"Thermal osteonecrosis and bone drill parameters revisited","volume":"128","author":"Augustin","year":"2008","journal-title":"Arch Orthoped Trauma Surg"},{"key":"10.1016\/j.foot.2018.02.002_bib0040","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.commatsci.2012.03.012","article-title":"Influence of drills parameters on bone temperature and necrosis: a FEM modeling and in vitro experiments","volume":"60","author":"Sezek","year":"2012","journal-title":"Comput Mater Sci"},{"key":"10.1016\/j.foot.2018.02.002_bib0045","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1016\/j.medengphy.2012.03.002","article-title":"An experimental investigation on thermal exposure during bone drilling","volume":"34","author":"Lee","year":"2012","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.foot.2018.02.002_bib0050","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/S0901-5027(06)80040-8","article-title":"Effect of drill speed on bone temperature","volume":"25","author":"Abouzgia","year":"1996","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1016\/j.foot.2018.02.002_bib0055","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1016\/S1350-4533(01)00016-9","article-title":"The effects of drilling force on cortical temperatures and their duration: an in vitro study","volume":"22","author":"Bachus","year":"2000","journal-title":"Med Eng Phys"},{"issue":"2","key":"10.1016\/j.foot.2018.02.002_bib0060","doi-asserted-by":"crossref","first-page":"297","DOI":"10.2106\/00004623-197254020-00008","article-title":"Temperatures measures in human cortical bone when drilling","volume":"54","author":"Matthews","year":"1972","journal-title":"J Joint Bone Surg"},{"issue":"8","key":"10.1016\/j.foot.2018.02.002_bib0065","doi-asserted-by":"crossref","first-page":"704","DOI":"10.7150\/ijms.8.704","article-title":"The effect of irrigation temperature on bone healing","volume":"8","author":"Isler","year":"2011","journal-title":"Int J Med Sci"},{"issue":"6","key":"10.1016\/j.foot.2018.02.002_bib0070","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.3901\/CJME.2014.0912.151","article-title":"Drilling force and temperature of bone under dry and physiological drilling conditions","volume":"27","author":"Linlin","year":"2014","journal-title":"Chin J Mech Eng"},{"key":"10.1016\/j.foot.2018.02.002_bib0075","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1007\/s00402-008-0630-x","article-title":"Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report","volume":"129","author":"Augustin","year":"2009","journal-title":"Arch Orthopaed Trauma Surg"},{"key":"10.1016\/j.foot.2018.02.002_bib0080","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/S0924-0136(99)00155-7","article-title":"Temperature effect in the drilling of human and bovine bone","volume":"92\u201393","author":"Hillery","year":"1999","journal-title":"J Mater Process Technol"},{"key":"10.1016\/j.foot.2018.02.002_bib0085","doi-asserted-by":"crossref","first-page":"29","DOI":"10.3109\/17453676608989401","article-title":"Factors affecting the determination of the physical properties of femoral cortical bone","volume":"37","author":"Sedlin","year":"1966","journal-title":"Acta Othopaed Scand"},{"issue":"10","key":"10.1016\/j.foot.2018.02.002_bib0090","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1016\/j.medengphy.2011.05.014","article-title":"A new thermal model for bone drilling with application to orthopaedic surgery","volume":"33","author":"Lee","year":"2011","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.foot.2018.02.002_bib0095","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1016\/j.joms.2007.12.037","article-title":"Evaluation of immediate bone-cell viability and of drill wear after implant osteotomies: immunohistochemistry and scanning electron microscopy analysis","volume":"66","author":"Queiroz","year":"2008","journal-title":"J Oral Maxillofac Surg"},{"issue":"1\u20134","key":"10.1016\/j.foot.2018.02.002_bib0100","first-page":"85","article-title":"Grading of osteoporosis in autopsy specimens: a new method","volume":"32","author":"Lindahi","year":"2009","journal-title":"Acta Orthopaed Scand"},{"key":"10.1016\/j.foot.2018.02.002_bib0105","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1034\/j.1600-0501.1997.080305.x","article-title":"Influence of different parameters on bone heating and drilling time in implantology","volume":"8","author":"Reingewirtz","year":"1997","journal-title":"Clin Oral Implant Res"},{"key":"10.1016\/j.foot.2018.02.002_bib0110","series-title":"Optimization of drill design and coolant systems during dental implant surgery","author":"Kalindindi","year":"2004"},{"issue":"3","key":"10.1016\/j.foot.2018.02.002_bib0115","first-page":"103","article-title":"Investigation into bone drilling and thermal bone necrosis","volume":"2","author":"Udiljak","year":"2007","journal-title":"Adv Prod Eng Manag"},{"key":"10.1016\/j.foot.2018.02.002_bib0120","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.cuor.2005.09.011","article-title":"The thermal properties of bone and the effects of surgical intervention","volume":"20","author":"Karmani","year":"2006","journal-title":"Curr Orthopaed"},{"key":"10.1016\/j.foot.2018.02.002_bib0125","first-page":"522","article-title":"Temperature change in pig rib bone during implant site preparation by low-speed drilling","author":"Kim","year":"2009","journal-title":"J Appl Oral Sci"},{"key":"10.1016\/j.foot.2018.02.002_bib0130","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1034\/j.1600-0501.2002.130309.x","article-title":"Thermal changes observed at implant sites during internal and external irrigation","volume":"13","author":"Benington","year":"2002","journal-title":"Clin Oral Implants Res"}],"container-title":["The Foot"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958259217301487?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0958259217301487?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T09:27:53Z","timestamp":1760693273000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0958259217301487"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6]]},"references-count":26,"alternative-id":["S0958259217301487"],"URL":"https:\/\/doi.org\/10.1016\/j.foot.2018.02.002","relation":{},"ISSN":["0958-2592"],"issn-type":[{"value":"0958-2592","type":"print"}],"subject":[],"published":{"date-parts":[[2018,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Measurement of temperature induced in bone during drilling in minimally invasive foot surgery","name":"articletitle","label":"Article Title"},{"value":"The Foot","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.foot.2018.02.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}