{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T01:09:40Z","timestamp":1790384980182,"version":"4.1.0"},"reference-count":60,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100002322","name":"CAPES","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002322","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003593","name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico","doi-asserted-by":"publisher","award":["404049\/2021-4"],"award-info":[{"award-number":["404049\/2021-4"]}],"id":[{"id":"10.13039\/501100003593","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Gait &amp; Posture"],"published-print":{"date-parts":[[2024,9]]},"DOI":"10.1016\/j.gaitpost.2024.08.004","type":"journal-article","created":{"date-parts":[[2024,8,8]],"date-time":"2024-08-08T13:41:18Z","timestamp":1723124478000},"page":"543-552","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"special_numbering":"C","title":["Psychometric properties of wearable technologies to assess post-stroke gait parameters: A systematic review"],"prefix":"10.1016","volume":"113","author":[{"given":"Raiff Simplicio da","family":"Silva","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephano Tomaz da","family":"Silva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daiane Carla Rodrigues","family":"Cardoso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Amanda Ferreira","family":"Quirino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Heloiza Ara\u00fajo","family":"Silva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Larissa Araujo","family":"Gomes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jefferson Doolan","family":"Fernandes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raul Alexandre Nunes da Silva","family":"Oliveira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aline Braga Galv\u00e3o Silveira","family":"Fernandes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatiana Souza","family":"Ribeiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"10","key":"10.1016\/j.gaitpost.2024.08.004_bib1","doi-asserted-by":"crossref","DOI":"10.1016\/S1474-4422(21)00252-0","article-title":"Global, regional, and national burden of stroke and its risk factors, 1990\u20132019: a systematic analysis for the global burden of disease study 2019","volume":"20","author":"Feigin","year":"2021","journal-title":"Lancet Neurol."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib2","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/591013","article-title":"Walking adaptability after a stroke and its assessment in clinical settings","author":"Balasubramanian","year":"2014","journal-title":"Stroke Res. Treat."},{"issue":"15","key":"10.1016\/j.gaitpost.2024.08.004_bib3","doi-asserted-by":"crossref","first-page":"1791","DOI":"10.1080\/09638288.2017.1312570","article-title":"Performance and capacity-based measures of locomotion, compared to impairment-based measures, best predicted participation in individuals with hemiparesis due to stroke","volume":"40","author":"Faria-Fortini","year":"2018","journal-title":"Disabil. Rehabil."},{"issue":"6","key":"10.1016\/j.gaitpost.2024.08.004_bib4","first-page":"e98","article-title":"Guidelines for adult stroke rehabilitation and recovery: a guideline for healthcare professionals from the American Heart Association\/American Stroke Association","volume":"47","author":"Winstein","year":"2016"},{"key":"10.1016\/j.gaitpost.2024.08.004_bib5","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.humov.2019.01.011","article-title":"Minimal detectable change of kinematic and spatiotemporal parameters in patients with chronic stroke across three sessions of gait analysis","volume":"64","author":"Geiger","year":"2019","journal-title":"Hum. Mov. Sci."},{"issue":"9","key":"10.1016\/j.gaitpost.2024.08.004_bib6","doi-asserted-by":"crossref","first-page":"22089","DOI":"10.3390\/s150922089","article-title":"Inertial sensor-based gait recognition: A review","volume":"15","author":"Sprager","year":"2015","journal-title":"Sensors"},{"issue":"1","key":"10.1016\/j.gaitpost.2024.08.004_bib7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-021-00863-x","article-title":"Utilization of wearable technology to assess gait and mobility post-stroke: a systematic review","volume":"18","author":"Peters","year":"2021","journal-title":"J. Neuroeng. Rehabil."},{"issue":"4","key":"10.1016\/j.gaitpost.2024.08.004_bib8","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/j.pmr.2015.06.006","article-title":"Hemiparetic gait","volume":"26","author":"Sheffler","year":"2015","journal-title":"Phys. Med. Rehabil. Clin."},{"issue":"1","key":"10.1016\/j.gaitpost.2024.08.004_bib9","article-title":"Effectiveness of an ankle\u2013foot orthosis on walking in patients with stroke: A systematic review and meta-analysis","volume":"11","author":"Choo","year":"2021","journal-title":"Sci. Rep."},{"issue":"4","key":"10.1016\/j.gaitpost.2024.08.004_bib10","doi-asserted-by":"crossref","first-page":"362","DOI":"10.3109\/09638288.2015.1041615","article-title":"Physical activity profiles and sedentary behavior in people following stroke: a cross-sectional study.","volume":"38","author":"Paul","year":"2016","journal-title":"Disabil. Rehabil."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib11","doi-asserted-by":"crossref","DOI":"10.3389\/fneur.2021.650024","article-title":"Assessment methods of post-stroke gait: A scoping review of technology-driven approaches to gait characterization and analysis","volume":"12","author":"Mohan","year":"2021","journal-title":"Front. Neurol."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib12","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"Bmj"},{"issue":"1","key":"10.1016\/j.gaitpost.2024.08.004_bib13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12874-017-0468-4","article-title":"What kind of systematic review should I conduct? a proposed typology and guidance for systematic reviewers in the medical and health sciences","volume":"18","author":"Munn","year":"2018","journal-title":"BMC Med. Res. Methodol."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib14","doi-asserted-by":"crossref","first-page":"677","DOI":"10.12688\/f1000research.134161.2","article-title":"Psychometric properties of portable devices used in kinematic gait assessment after stroke: a systematic review protocol","volume":"12","author":"Silva","year":"2024","journal-title":"F1000Research"},{"issue":"1","key":"10.1016\/j.gaitpost.2024.08.004_bib15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12874-020-01179-5","article-title":"COSMIN Risk of Bias tool to assess the quality of studies on reliability or measurement error of outcome measurement instruments: a Delphi study","volume":"20","author":"Mokkink","year":"2020","journal-title":"BMC Med. Res. Methodol."},{"issue":"1","key":"10.1016\/j.gaitpost.2024.08.004_bib16","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1007\/s11136-018-1798-3","article-title":"COSMIN guideline for systematic reviews of Patient-Reported Outcome Measures","volume":"27","author":"Prinsen","year":"2018","journal-title":"Qual. Life Res"},{"key":"10.1016\/j.gaitpost.2024.08.004_bib17","doi-asserted-by":"crossref","first-page":"6979","DOI":"10.3390\/s21216976","article-title":"Estimation of walking speed and its spatiotemporal determinants using a single inertial sensor worn on the thigh: from healthy to hemiparetic walking","volume":"21","author":"Arumukhom Revi","year":"2021","journal-title":"Sensors"},{"issue":"2","key":"10.1016\/j.gaitpost.2024.08.004_bib18","doi-asserted-by":"crossref","first-page":"624","DOI":"10.3390\/s23020624","article-title":"Reliability and Validity of a Wearable Sensing System and Online Gait Analysis Report in Persons after Stroke","author":"Schwarz","year":"2023","journal-title":"Sensors"},{"issue":"5","key":"10.1016\/j.gaitpost.2024.08.004_bib19","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1682\/JRRD.2015.04.0065","article-title":"Reliability and validity of the inertial sensor-based Timed\" Up and Go\" test in individuals affected by stroke","volume":"53","author":"W\u00fcest","year":"2016","journal-title":"J. Rehabil. Res. Dev."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib20","doi-asserted-by":"crossref","DOI":"10.1017\/wtc.2020.11","article-title":"Real-time gait metric estimation for everyday gait training with wearable devices in people poststroke","volume":"2","author":"Arens","year":"2021","journal-title":"Wearable Technol."},{"issue":"4","key":"10.1016\/j.gaitpost.2024.08.004_bib21","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1080\/10749357.2018.1446487","article-title":"Validity of the ActiGraph activity monitor for individuals who walk slowly post-stroke","volume":"25","author":"Campos","year":"2018","journal-title":"Top. Stroke Rehabil."},{"issue":"6","key":"10.1016\/j.gaitpost.2024.08.004_bib22","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1080\/10749357.2019.1623474","article-title":"Gait quality and velocity influences activity tracker accuracy in individuals post-stroke","volume":"26","author":"Clay","year":"2010","journal-title":"Top. Stroke Rehabil."},{"issue":"11","key":"10.1016\/j.gaitpost.2024.08.004_bib23","doi-asserted-by":"crossref","first-page":"2497","DOI":"10.3390\/s19112497","article-title":"Validity of the walked distance estimated by wearable devices in stroke individuals","volume":"19","author":"Compagnat","year":"2019","journal-title":"Sensors"},{"key":"10.1016\/j.gaitpost.2024.08.004_bib24","series-title":"41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","first-page":"3286","article-title":"Agreement between opal and G-walk wearable inertial systems in gait analysis on normal and pathological subjects","author":"D\u2019Addio","year":"2019"},{"issue":"8","key":"10.1016\/j.gaitpost.2024.08.004_bib25","first-page":"2246","article-title":"Reliability and validity of bilateral ankle accelerometer algorithms for activity recognition and walking speed after stroke","volume":"42","author":"Dobkin","year":"2011","journal-title":"Stroke, 2011"},{"issue":"9","key":"10.1016\/j.gaitpost.2024.08.004_bib26","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1002\/pmrj.12080","article-title":"Activity monitor placed at the nonparetic ankle is accurate in measuring step counts during community walking in poststroke individuals: a validation study","volume":"11","author":"Duclos","year":"2019","journal-title":"PMR"},{"issue":"2","key":"10.1016\/j.gaitpost.2024.08.004_bib27","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1080\/10749357.2020.1792717","article-title":"FeetMe\u00ae Monitor-connected insoles are a valid and reliable alternative for the evaluation of gait speed after stroke","volume":"28","author":"Farid","year":"2021","journal-title":"Top. Stroke Rehabil."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib28","series-title":"In2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","first-page":"5211","article-title":"Characterizing walking activity in people with stroke","author":"Fulk","year":"2011"},{"issue":"2","key":"10.1016\/j.gaitpost.2024.08.004_bib29","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1097\/NPT.0b013e318256370c","article-title":"Identifying activity levels and steps of people with stroke using a novel shoe-based sensor","volume":"36","author":"Fulk","year":"2012","journal-title":"J. Neurol. Phys. Ther."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib30","doi-asserted-by":"crossref","DOI":"10.3389\/fphys.2022.857963","article-title":"Agreement, reliability, and concurrent validity of an outdoor, wearable-based walk ratio assessment in healthy adults and chronic stroke survivors","volume":"13","author":"Huber","year":"2022","journal-title":"Front. Physiol."},{"issue":"1","key":"10.1016\/j.gaitpost.2024.08.004_bib31","doi-asserted-by":"crossref","first-page":"81","DOI":"10.3138\/ptc.2016-40.ep","article-title":"Validity of the Fitbit One for measuring activity in community-dwelling stroke survivors","volume":"70","author":"Hui","year":"2018","journal-title":"Physiother. Can."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib32","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-018-0358-y","article-title":"Variables influencing wearable sensor outcome estimates in individuals with stroke and incomplete spinal cord injury: a pilot investigation validating two research grade sensors","volume":"15","author":"Jayaraman","year":"2018","journal-title":"J. Neuroeng. Rehabil."},{"issue":"1","key":"10.1016\/j.gaitpost.2024.08.004_bib33","doi-asserted-by":"crossref","DOI":"10.2196\/14494","article-title":"Physical activity monitoring using a fitbit device in ischemic stroke patients: prospective cohort feasibility study","volume":"9","author":"Katzan","year":"2021","journal-title":"JMIR mHealth uHealth"},{"issue":"3","key":"10.1016\/j.gaitpost.2024.08.004_bib34","doi-asserted-by":"crossref","first-page":"355","DOI":"10.2522\/ptj.20140611","article-title":"\u201cStepping up\u201d activity poststroke: ankle-positioned accelerometer can accurately record steps during slow walking","volume":"96","author":"Klassen","year":"2016","journal-title":"Phys. Ther."},{"issue":"9","key":"10.1016\/j.gaitpost.2024.08.004_bib35","doi-asserted-by":"crossref","first-page":"2614","DOI":"10.1161\/STROKEAHA.117.018175","article-title":"Consumer-based physical activity monitor as a practical way to measure walking intensity during inpatient stroke rehabilitation","volume":"48","author":"Klassen","year":"2017","journal-title":"Stroke"},{"key":"10.1016\/j.gaitpost.2024.08.004_bib36","doi-asserted-by":"crossref","DOI":"10.1155\/2018\/9134547","article-title":"Validity of multisensor array for measuring energy expenditure of an activity bout in early stroke survivors","author":"Kramer","year":"2018","journal-title":"Stroke Res. Treat."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib37","series-title":"In2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","first-page":"5195","article-title":"Repeatability of the accelerometric-based method to detect step events for hemiparetic stroke patients","author":"Lee","year":"2011"},{"issue":"9","key":"10.1016\/j.gaitpost.2024.08.004_bib38","doi-asserted-by":"crossref","first-page":"1865","DOI":"10.1109\/TNSRE.2019.2930751","article-title":"D. Beckw\u00e9e, Validity and reproducibility of inertial physilog sensors for spatiotemporal gait analysis in patients with stroke","volume":"27","author":"Lefeber","year":"2019","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"issue":"2","key":"10.1016\/j.gaitpost.2024.08.004_bib39","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1017\/BrImp.2016.13","article-title":"Are Accelerometers and GPS Devices Valid, Reliable and Feasible Tools for Measurement of Community Ambulation After Stroke? 1","volume":"17","author":"Mahendran","year":"2016","journal-title":"Brain Impair."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib40","doi-asserted-by":"crossref","DOI":"10.1155\/2012\/247165","article-title":"SenseWear armband and stroke: validity of energy expenditure and step count measurement during walking","author":"Manns","year":"2012","journal-title":"Stroke Res. Treat."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib41","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-017-0341-z","article-title":"Comprehensive measurement of stroke gait characteristics with a single accelerometer in the laboratory and community: a feasibility, validity and reliability study","volume":"14","author":"Moore","year":"2017","journal-title":"J. Neuroeng. Rehabil."},{"issue":"9","key":"10.1016\/j.gaitpost.2024.08.004_bib42","doi-asserted-by":"crossref","first-page":"3177","DOI":"10.3390\/ijerph17093177","article-title":"Using an accelerometer-based step counter in post-stroke patients: validation of a low-cost tool","volume":"17","author":"Negrini","year":"2020","journal-title":"Int. J. Environ. Res. Public Health"},{"issue":"2","key":"10.1016\/j.gaitpost.2024.08.004_bib43","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1589\/jpts.29.307","article-title":"Validity of gait asymmetry estimation by using an accelerometer in individuals with hemiparetic stroke","volume":"29","author":"Oyake","year":"2017","journal-title":"J. Phys. Ther. Sci."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib44","series-title":"IEEE 13th International Conference on Wearable and Implantable Body Sensor Networks (BSN)","first-page":"335","article-title":"Accurate gait analysis in post-stroke patients using a single inertial measurement unit, In2016","author":"Parisi","year":"2016"},{"issue":"3","key":"10.1016\/j.gaitpost.2024.08.004_bib45","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/j.jbmt.2019.01.011","article-title":"Google fit smartphone application or Gt3X Actigraph: which is better for detecting the stepping activity of individuals with stroke? A validity study","volume":"23","author":"Polese","year":"2019","journal-title":"J. Bodyw. Mov. Ther."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib46","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1743-0003-11-30","article-title":"Clinimetric properties of a novel feedback device for assessing gait parameters in stroke survivors","volume":"11","author":"Punt","year":"2014","journal-title":"J. Neuroeng. Rehabil."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib47","series-title":"In2022 International Conference on Rehabilitation Robotics (ICORR)","first-page":"1","article-title":"Centroidal Moment Pivot for ambulatory estimation of relative feet and CoM movement post stroke: Portable Gait Lab","author":"Refai","year":"2022"},{"issue":"1","key":"10.1016\/j.gaitpost.2024.08.004_bib48","doi-asserted-by":"crossref","DOI":"10.2196\/cardio.8199","article-title":"Consumer wearable devices for activity monitoring among individuals after a stroke: a prospective comparison","volume":"2","author":"Rozanski","year":"2018","journal-title":"JMIR cardio"},{"issue":"2","key":"10.1016\/j.gaitpost.2024.08.004_bib49","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1177\/1545968306287171","article-title":"Reliability and validity of bilateral thigh and foot accelerometry measures of walking in healthy and hemiparetic subjects","volume":"20","author":"Saremi","year":"2006","journal-title":"Neurorehabilitation Neural Repair"},{"issue":"10","key":"10.1016\/j.gaitpost.2024.08.004_bib50","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1080\/09593985.2017.1354412","article-title":"Step count accuracy and reliability of two activity tracking devices in people after stroke","volume":"33","author":"Schaffer","year":"2017","journal-title":"Physiother. Theory Pract."},{"issue":"20","key":"10.1016\/j.gaitpost.2024.08.004_bib51","doi-asserted-by":"crossref","first-page":"1695","DOI":"10.3109\/09638288.2013.859307","article-title":"Physical activity monitoring in stroke: SenseWear Pro2 activity accelerometer versus Yamax Digi-Walker SW-200 pedometer","volume":"36","author":"Vanroy","year":"2014","journal-title":"Disabil. Rehabil."},{"issue":"3","key":"10.1016\/j.gaitpost.2024.08.004_bib52","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1016\/j.gaitpost.2012.07.032","article-title":"Estimation of spatio-temporal parameters for post-stroke hemiparetic gait using inertial sensors","volume":"37","author":"Yang","year":"2013","journal-title":"Gait Posture"},{"issue":"10","key":"10.1016\/j.gaitpost.2024.08.004_bib53","doi-asserted-by":"crossref","first-page":"3322","DOI":"10.3390\/s18103322","article-title":"Gait symmetry assessment with a low back 3d accelerometer in post-stroke patients","volume":"18","author":"Zhang","year":"2018","journal-title":"Sensors"},{"issue":"1","key":"10.1016\/j.gaitpost.2024.08.004_bib54","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1589\/jpts.35.75","article-title":"Relative and absolute reliability of gait variables obtained from gait analysis with trunk acceleration in community-dwelling individuals with chronic stroke: a pilot study","volume":"35","author":"Fujimoto","year":"2023","journal-title":"J. Phys. Ther. Sci."},{"issue":"5","key":"10.1016\/j.gaitpost.2024.08.004_bib55","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.apmr.2018.10.006","article-title":"Two days of measurement provides reliable estimates of physical activity poststroke: an observational study","volume":"100","author":"Fini","year":"2019","journal-title":"Arch. Phys. Med. Rehabil."},{"issue":"12","key":"10.1016\/j.gaitpost.2024.08.004_bib56","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1016\/j.apmr.2003.11.035","article-title":"Accelerometer monitoring of home-and community-based ambulatory activity after stroke","volume":"85","author":"Haeuber","year":"2004","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"10.1016\/j.gaitpost.2024.08.004_bib57","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1177\/0269215508092822","article-title":"Test\u2014retest reliability of the StepWatch Activity Monitor outputs in individuals with chronic stroke","author":"Mudge","year":"2008","journal-title":"Clin. Rehabil., 22 (10-11)"},{"issue":"2","key":"10.1016\/j.gaitpost.2024.08.004_bib58","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"issue":"12","key":"10.1016\/j.gaitpost.2024.08.004_bib59","doi-asserted-by":"crossref","first-page":"11556","DOI":"10.3390\/s101211556","article-title":"The use of wearable inertial motion sensors in human lower limb biomechanics studies: A systematic review","volume":"10","author":"Fong","year":"2010","journal-title":"Sensors"},{"issue":"7","key":"10.1016\/j.gaitpost.2024.08.004_bib60","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.3390\/s19071555","article-title":"Validity and reliability of wearable sensors for joint angle estimation: A systematic review","volume":"19","author":"Poitras","year":"2019","journal-title":"Sensors"}],"container-title":["Gait &amp; Posture"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0966636224005186?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0966636224005186?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,9,7]],"date-time":"2024-09-07T14:49:40Z","timestamp":1725720580000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0966636224005186"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9]]},"references-count":60,"alternative-id":["S0966636224005186"],"URL":"https:\/\/doi.org\/10.1016\/j.gaitpost.2024.08.004","relation":{},"ISSN":["0966-6362"],"issn-type":[{"value":"0966-6362","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Psychometric properties of wearable technologies to assess post-stroke gait parameters: A systematic review","name":"articletitle","label":"Article Title"},{"value":"Gait & Posture","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.gaitpost.2024.08.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}