{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T13:10:05Z","timestamp":1789650605626,"version":"4.0.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["DK007056"],"award-info":[{"award-number":["DK007056"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","giejournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Gastrointestinal Endoscopy"],"published-print":{"date-parts":[[2019,1]]},"DOI":"10.1016\/j.gie.2018.08.012","type":"journal-article","created":{"date-parts":[[2018,8,17]],"date-time":"2018-08-17T12:57:12Z","timestamp":1534510632000},"page":"115-123","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":62,"title":["Simethicone is retained in endoscopes despite reprocessing: impact of its use on working channel fluid retention and adenosine triphosphate bioluminescence values (with video)"],"prefix":"10.1016","volume":"89","author":[{"given":"Monique T.","family":"Barakat","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert J.","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Subhas","family":"Banerjee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.gie.2018.08.012_bib1","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1111\/jgh.12487","article-title":"Efficacy of simethicone and N-acetylcysteine as premedication in improving visibility during upper endoscopy","volume":"29","author":"Chang","year":"2014","journal-title":"J\u00a0Gastroenterol Hepatol"},{"key":"10.1016\/j.gie.2018.08.012_bib2","series-title":"Simethicone: letter to health care practitioner","author":"Catalone","year":"2009"},{"key":"10.1016\/j.gie.2018.08.012_bib3","unstructured":"PENTAX Medical Company [instructions for use]. Pentax Video GI Scopes 90i Series 90K Series. Tokyo, Japan: Hoya Corporation;\u00a02014."},{"key":"10.1016\/j.gie.2018.08.012_bib4","unstructured":"Fujinon Films USA ED [reprocessing summary and guide for Fujinon\/Fujifilm flexible GI endoscopes]. 2012."},{"key":"10.1016\/j.gie.2018.08.012_bib5","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1016\/j.ajic.2016.05.016","article-title":"Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing","volume":"44","author":"Ofstead","year":"2016","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.gie.2018.08.012_bib6","doi-asserted-by":"crossref","first-page":"E394","DOI":"10.1055\/s-0042-120261","article-title":"Crystallization in the waterjet channel in colonoscopes due to simethicone","volume":"48","author":"van Stiphout","year":"2016","journal-title":"Endoscopy"},{"key":"10.1016\/j.gie.2018.08.012_bib7","doi-asserted-by":"crossref","unstructured":"Barakat MT, Girotra M, Huang RJ, et\u00a0al. Scoping the scope: endoscopic evaluation of endoscope working channels with a new high-resolution inspection endoscope (with video). Gastrointest Endosc. Epub 2018 Feb\u00a06.","DOI":"10.1016\/j.gie.2018.01.018"},{"key":"10.1016\/j.gie.2018.08.012_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/j.gie.2016.10.035","article-title":"Adenosine triphosphate bioluminescence for bacteriologic surveillance and reprocessing strategies for minimizing risk of infection transmission by duodenoscopes","volume":"85","author":"Sethi","year":"2017","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.gie.2018.08.012_bib9","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.ajic.2012.03.015","article-title":"The adenosine triphosphate test is a rapid and reliable audit tool to assess manual cleaning adequacy of flexible endoscope channels","volume":"41","author":"Alfa","year":"2013","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.gie.2018.08.012_bib10","unstructured":"Reprocessing Guideline Task Force; Petersen BT, Cohen J, Hambrick RD 3rd, et\u00a0al. Multisociety guideline on reprocessing flexible GI endoscopes: 2016 update. Gastrointest Endosc. Epub 2017 Jan\u00a06."},{"key":"10.1016\/j.gie.2018.08.012_bib11","doi-asserted-by":"crossref","unstructured":"Kovaleva J. Endoscope drying and its pitfalls. J Hosp Infect. Epub 2017 Jul\u00a017.","DOI":"10.1016\/j.jhin.2017.07.012"},{"key":"10.1016\/j.gie.2018.08.012_bib12","doi-asserted-by":"crossref","first-page":"1675","DOI":"10.1016\/j.ajic.2016.06.029","article-title":"Assessing residual contamination and damage inside flexible endoscopes over time","volume":"44","author":"Ofstead","year":"2016","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.gie.2018.08.012_bib13","doi-asserted-by":"crossref","first-page":"e26","DOI":"10.1016\/j.ajic.2016.10.017","article-title":"Longitudinal assessment of reprocessing effectiveness for colonoscopes and gastroscopes: results of visual inspections, biochemical markers, and microbial cultures","volume":"45","author":"Ofstead","year":"2017","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.gie.2018.08.012_bib14","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1055\/s-0032-1326186","article-title":"Bowel preparation for colonoscopy: European Society of Gastrointestinal Endoscopy (ESGE) guideline","volume":"45","author":"Hassan","year":"2013","journal-title":"Endoscopy"},{"key":"10.1016\/j.gie.2018.08.012_bib15","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1111\/den.12952","article-title":"Efficacy and safety of using premedication with simethicone\/Pronase during upper gastrointestinal endoscopy examination with sedation: a single center, prospective, single blinded, randomized controlled trial","volume":"30","author":"Zhang","year":"2018","journal-title":"Dig Endosc"},{"key":"10.1016\/j.gie.2018.08.012_bib16","first-page":"139","article-title":"Premedication with simethicone and N-acetylcysteine in improving visibility during upper endoscopy: a double-blind randomized trial","volume":"49","author":"Elvas","year":"2017","journal-title":"Endoscopy"},{"key":"10.1016\/j.gie.2018.08.012_bib17","doi-asserted-by":"crossref","first-page":"227","DOI":"10.3109\/00365521.2010.525714","article-title":"Systematic review and meta-analysis of randomized controlled trials of Simethicone for gastrointestinal endoscopic visibility","volume":"46","author":"Wu","year":"2011","journal-title":"Scand J Gastroenterol"},{"key":"10.1016\/j.gie.2018.08.012_bib18","doi-asserted-by":"crossref","first-page":"e26","DOI":"10.1038\/ctg.2012.16","article-title":"The effect on colon visualization during colonoscopy of the addition of simethicone to polyethylene glycol-electrolyte solution: a randomized single-blind study","volume":"3","author":"Matro","year":"2012","journal-title":"Clin Transl Gastroenterol"},{"key":"10.1016\/j.gie.2018.08.012_bib19","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1128\/CMR.00085-12","article-title":"Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy","volume":"26","author":"Kovaleva","year":"2013","journal-title":"Clin Microbiol Rev"},{"key":"10.1016\/j.gie.2018.08.012_bib20","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.ajic.2012.03.018","article-title":"Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels","volume":"41","author":"Alfa","year":"2013","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.gie.2018.08.012_bib21","first-page":"Doc04","article-title":"ATP measurement as method to monitor the quality of reprocessing flexible endoscopes","volume":"2","author":"Hansen","year":"2004","journal-title":"Ger Med Sci"},{"key":"10.1016\/j.gie.2018.08.012_bib22","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1186\/2047-2994-4-S1-P56","article-title":"Monitoring the efficacy of the cleaning and disinfection process for flexible endoscopes by quantification of multiple biological markers","volume":"4","author":"Bommarito","year":"2015","journal-title":"Antimicrob Resist Infect Control"},{"key":"10.1016\/j.gie.2018.08.012_bib23","first-page":"190","article-title":"Efficacy and limitations of an ATP-based monitoring system","volume":"49","author":"Turner","year":"2010","journal-title":"J\u00a0Am Assoc Lab Anim Sci"},{"key":"10.1016\/j.gie.2018.08.012_bib24","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.gie.2017.03.1544","article-title":"Duodenoscope reprocessing surveillance with adenosine triphosphate testing and terminal cultures: a clinical pilot study","volume":"86","author":"Visrodia","year":"2017","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.gie.2018.08.012_bib25","first-page":"1","article-title":"CAG position statement: the impact of simethicone on endoscope reprocessing","year":"2017","journal-title":"Canadian Association of Gastroenterology"}],"container-title":["Gastrointestinal Endoscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0016510718329328?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0016510718329328?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T17:13:35Z","timestamp":1758042815000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0016510718329328"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["S0016510718329328"],"URL":"https:\/\/doi.org\/10.1016\/j.gie.2018.08.012","relation":{},"ISSN":["0016-5107"],"issn-type":[{"value":"0016-5107","type":"print"}],"subject":[],"published":{"date-parts":[[2019,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Simethicone is retained in endoscopes despite reprocessing: impact of its use on working channel fluid retention and adenosine triphosphate bioluminescence values (with video)","name":"articletitle","label":"Article Title"},{"value":"Gastrointestinal Endoscopy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.gie.2018.08.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 by the American Society for Gastrointestinal Endoscopy","name":"copyright","label":"Copyright"}]}}