{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T17:41:23Z","timestamp":1761154883421},"reference-count":18,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2006,3,1]],"date-time":"2006-03-01T00:00:00Z","timestamp":1141171200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Gyn\u00e9cologie Obst\u00e9trique &amp; Fertilit\u00e9"],"published-print":{"date-parts":[[2006,3]]},"DOI":"10.1016\/j.gyobfe.2006.01.029","type":"journal-article","created":{"date-parts":[[2006,3,7]],"date-time":"2006-03-07T07:09:30Z","timestamp":1141715370000},"page":"202-208","source":"Crossref","is-referenced-by-count":9,"title":["St\u00e9rilisation tubaire par voie hyst\u00e9roscopique\u00a0: faisabilit\u00e9 et \u00e9valuation \u00e0 un an"],"prefix":"10.1016","volume":"34","author":[{"given":"E.","family":"Gibon","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Lop\u00e8s","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Linet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Martigny","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Orieux","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.-J.","family":"Philippe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.gyobfe.2006.01.029_bib1","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1111\/j.1479-828X.2001.tb01311.x","article-title":"The safety and effectiveness of a new hysteroscopic method for permanent birth control: result of the first Essure\u00ae pbc clinical study","volume":"41","author":"Kerin","year":"2001","journal-title":"Aust. NZ J. Obstet. Gynecol."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib2","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1016\/S0015-0282(01)02858-8","article-title":"Tissu response to the STOP microcoil transcervical permanent contraceptive device: results from a pre hysterectomy study","volume":"76","author":"Valle","year":"2001","journal-title":"Feril. Steril."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib3","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1016\/j.fertnstert.2004.10.056","article-title":"Proximal occlusion of hydrosalpinx by hysteroscopic placement of microinsert before in vitro fertilization-embryo transfer","volume":"83","author":"Rosenfield","year":"2005","journal-title":"Fertil. Steril."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib4","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.jmig.2005.05.016","article-title":"Office hysteroscopic sterilization compared with laparoscopic sterilization: a critical cost analysis","volume":"12","author":"Levie","year":"2005","journal-title":"J. Minim. Invasive Gynecol."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib5","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1016\/S0029-7844(00)01082-6","article-title":"Complications of interval laparoscopic tubal sterilization: findings from the United States collaborative review of sterilization","volume":"96","author":"Jamieson","year":"2000","journal-title":"Obstet. Gynecol."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib6","first-page":"574","article-title":"Laparoscopic sterilization. American association of gynecologic laparoscoists 1991 membership survey","volume":"38","author":"Peterson","year":"1993","journal-title":"J. Reprod. Med."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib7","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1016\/S1297-9589(01)00193-X","article-title":"Complications de la c\u0153lioscopie en gyn\u00e9cologie","volume":"29","author":"Chapron","year":"2001","journal-title":"Gynecol. Obstet. Fertil."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib8","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1016\/S1297-9589(00)00025-4","article-title":"Complications vasculaires majeures de la c\u0153lioscopie gyn\u00e9cologique","volume":"28","author":"Chapron","year":"2000","journal-title":"Gynecol. Obstet. Fertil."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib9","first-page":"497","article-title":"Complications de la c\u0153lioscopie diagnostique","volume":"23","author":"Bremond","year":"1994","journal-title":"J. Gynecol. Obstet. Biol. Reprod. (Paris)"},{"key":"10.1016\/j.gyobfe.2006.01.029_bib10","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/0304-3959(89)90006-7","article-title":"The prevalence and impact of pain after day-care tubal ligation surgery","volume":"39","author":"Fraser","year":"1989","journal-title":"Pain"},{"key":"10.1016\/j.gyobfe.2006.01.029_bib11","first-page":"895","article-title":"Economic and clinical outcomes of microlaparoscopic and standard laparoscopic sterilization. A comparison","volume":"45","author":"Garcia","year":"2000","journal-title":"J. Reprod. Med."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib12","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1093\/humrep\/deg256","article-title":"Hysteroscopic sterilization using a micro insert device: results of a multi center phase 2 study","volume":"18","author":"Kerin","year":"2003","journal-title":"Hum. Reprod."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib13","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1111\/j.1471-0528.2004.00310.x","article-title":"Hysteroscopi sterilisation: a study of women's attitudes to a novel procedure","volume":"11","author":"Baxter","year":"2005","journal-title":"BJOG"},{"key":"10.1016\/j.gyobfe.2006.01.029_bib14","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/S0029-7844(03)00373-9","article-title":"Micro-insert nonincisional hysteroscopic sterilization","volume":"102","author":"Cooper","year":"2003","journal-title":"Obstet. Gynecol."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib15","first-page":"115","article-title":"Permanent sterilization for the 21st century using the hysteroscopic approach","volume":"13","author":"Collins","year":"2004","journal-title":"Surg. Technol. Int."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib16","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.fertnstert.2003.12.032","article-title":"Essure\u00ae: a new device for hysteroscopic tubal sterilization in an oupatient setting","volume":"82","author":"Ubeda","year":"2004","journal-title":"Feril. Steril."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib17","doi-asserted-by":"crossref","DOI":"10.1093\/humrep\/dei232","article-title":"Hysteroscopic permanent tubal sterilization using a nitinol-dacron intratubal device without anaesthesia in the oupatient setting: procedure feasibility and effectiveness","author":"Litta","year":"2005","journal-title":"Hum. Reprod."},{"key":"10.1016\/j.gyobfe.2006.01.029_bib18","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/S1074-3804(05)60056-4","article-title":"Essure\u00ae hysteroscopic sterilization: results based on utlizing a new coil catheter delivery system","volume":"11","author":"Kerin","year":"2004","journal-title":"J. Am. Assoc. Gynecol. Laparosc."}],"container-title":["Gyn\u00e9cologie Obst\u00e9trique &amp; Fertilit\u00e9"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1297958906000518?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1297958906000518?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,1,17]],"date-time":"2019-01-17T20:21:49Z","timestamp":1547756509000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1297958906000518"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,3]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2006,3]]}},"alternative-id":["S1297958906000518"],"URL":"https:\/\/doi.org\/10.1016\/j.gyobfe.2006.01.029","relation":{},"ISSN":["1297-9589"],"issn-type":[{"value":"1297-9589","type":"print"}],"subject":[],"published":{"date-parts":[[2006,3]]}}}