{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T20:31:53Z","timestamp":1790368313640,"version":"4.1.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T00:00:00Z","timestamp":1559347200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T00:00:00Z","timestamp":1559347200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,5,30]],"date-time":"2020-05-30T00:00:00Z","timestamp":1590796800000},"content-version":"am","delay-in-days":364,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Hand Surgery and Rehabilitation"],"published-print":{"date-parts":[[2019,6]]},"DOI":"10.1016\/j.hansur.2019.01.001","type":"journal-article","created":{"date-parts":[[2019,1,27]],"date-time":"2019-01-27T07:37:28Z","timestamp":1548574648000},"page":"186-190","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"title":["Distal interphalangeal joint arthrodesis using the X-Fuse\u00ae implant: A retrospective study of 54 fingers with 24 months\u2019 follow-up"],"prefix":"10.1016","volume":"38","author":[{"given":"Y.K.","family":"De Almeida","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Athlani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Dap","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Dautel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hansur.2019.01.001_bib0005","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1016\/j.jhsa.2013.01.017","article-title":"Distal interphalangeal joint arthrodesis with the reverse fix nail","volume":"38","author":"Matsumoto","year":"2013","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0010","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jhsa.2007.09.004","article-title":"Alternative to the distal interphalangeal joint arthrodesis: lateral approach and plate fixation","volume":"33","author":"Mantovani","year":"2008","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0015","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1097\/BTH.0b013e31829ba688","article-title":"Distal interphalangeal joint arthrodesis using nitinol intramedullary fixation implants: X-Fuse implants for DIP arthrodesis","volume":"17","author":"Seitz","year":"2013","journal-title":"Tech Hand Up Extrem"},{"key":"10.1016\/j.hansur.2019.01.001_bib0020","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1016\/S0363-5023(09)91081-4","article-title":"Distal interphalangeal joint arthrodesis: an analysis of complications","volume":"17","author":"Stern","year":"1992","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0025","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.jhsa.2005.09.009","article-title":"Use of a headless compressive screw for distal interphalangeal joint arthrodesis in digits: clinical outcome and review of complications","volume":"31","author":"Brutus","year":"2006","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0030","doi-asserted-by":"crossref","first-page":"2360","DOI":"10.1016\/j.jhsa.2013.09.026","article-title":"An obliquely placed headless compression screw for distal interphalangeal joint arthrodesis","volume":"38","author":"Iwamoto","year":"2013","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0035","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1177\/1753193414527387","article-title":"Percutaneous in situ versus open arthrodesis of the distal interphalangeal joint","volume":"40","author":"Renfree","year":"2015","journal-title":"J Hand Surg Eur"},{"key":"10.1016\/j.hansur.2019.01.001_bib0040","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1016\/0363-5023(92)90476-6","article-title":"Results of small joints arthrodesis: Comparison of K-wire and tension band wire technique","volume":"17","author":"Ijsselstein","year":"1992","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0045","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.main.2015.01.002","article-title":"Arthrodesis of thumb interphalangeal and finger DIP joints using the intramedullary X-fuse\u00ae implant: Retrospective analysis of 38 cases","volume":"34","author":"Ameline","year":"2015","journal-title":"Chir Main"},{"key":"10.1016\/j.hansur.2019.01.001_bib0050","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.1097\/ACM.0b013e3182677805","article-title":"The Ottawa Surgical Competency Operating Room Evaluation (O-SCORE): a tool to assess surgical competence","volume":"87","author":"Gofton","year":"2012","journal-title":"Acad Med"},{"key":"10.1016\/j.hansur.2019.01.001_bib0055","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1002\/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO;2-L","article-title":"Development of an upper extremity outcome measure: the DASH (disabilities if the arm, shoulder and hand). The Upper Extremity Collaborative Group (UECG)","volume":"29","author":"Hudak","year":"1996","journal-title":"Am J Ind Med"},{"key":"10.1016\/j.hansur.2019.01.001_bib0060","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1097\/00005131-199811000-00009","article-title":"Patient rating of wrist pain and disabilities: a reliable and valid measurement tool","volume":"12","author":"MacDermid","year":"1998","journal-title":"J Orthop Trauma"},{"key":"10.1016\/j.hansur.2019.01.001_bib0065","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1016\/j.jhsa.2007.06.010","article-title":"Arthrodesis of the interphalangeal joints with headless compression screws","volume":"32","author":"Leibovic","year":"2007","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0070","doi-asserted-by":"crossref","first-page":"1986","DOI":"10.1016\/j.jhsa.2014.06.021","article-title":"Simulated distal interphalangeal joint fusion of the index and middle fingers in 0\u00b0 and 20\u00b0 of flexion: a comparison of grip strength and dexterity","volume":"39","author":"Melamed","year":"2014","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0075","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.main.2015.03.002","article-title":"Comparison of distal interphalangeal fusion with and without joint preparation in cases of stage IV chondropathy","volume":"34","author":"Matheron","year":"2015","journal-title":"Chir Main"},{"key":"10.1016\/j.hansur.2019.01.001_bib0080","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1016\/j.jhsa.2012.02.048","article-title":"Distal interphalangeal joint arthrodesis for degenerative osteoarthritis with compression screw: results in 102 digits","volume":"37","author":"Villani","year":"2012","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0085","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1016\/j.jhsa.2014.02.007","article-title":"Distal interphalangeal joint bony dimensions related to headless compression screw sizes","volume":"39","author":"Mintalucci","year":"2014","journal-title":"J Hand Surg Am"},{"key":"10.1016\/j.hansur.2019.01.001_bib0090","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1097\/00006534-197710000-00019","article-title":"A comparison between K-wire and compression screw fixation after arthrodesis of the distal interphalangeal joint","volume":"60","author":"Engel","year":"1977","journal-title":"Plast Reconstr Surg"},{"key":"10.1016\/j.hansur.2019.01.001_bib0095","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1177\/1558944715627211","article-title":"Biomechanical analysis of internal fixation methods for distal interphalangeal joint arthrodesis","volume":"11","author":"Rigot","year":"2016","journal-title":"Hand (N Y)"}],"container-title":["Hand Surgery and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468122919300209?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468122919300209?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T04:50:58Z","timestamp":1762836658000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2468122919300209"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6]]},"references-count":19,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,6]]}},"alternative-id":["S2468122919300209"],"URL":"https:\/\/doi.org\/10.1016\/j.hansur.2019.01.001","relation":{},"ISSN":["2468-1229"],"issn-type":[{"value":"2468-1229","type":"print"}],"subject":[],"published":{"date-parts":[[2019,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Distal interphalangeal joint arthrodesis using the X-Fuse\u00ae implant: A retrospective study of 54 fingers with 24 months\u2019 follow-up","name":"articletitle","label":"Article Title"},{"value":"Hand Surgery and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hansur.2019.01.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 SFCM. Published by Elsevier Masson SAS. All rights reserved.","name":"copyright","label":"Copyright"}]}}