{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T11:50:57Z","timestamp":1779105057951,"version":"3.51.4"},"reference-count":19,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2005,7,1]],"date-time":"2005-07-01T00:00:00Z","timestamp":1120176000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2005,7,1]],"date-time":"2005-07-01T00:00:00Z","timestamp":1120176000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100000925","name":"National Health and Medical Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000925","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jhltonline.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Heart and Lung Transplantation"],"published-print":{"date-parts":[[2005,7]]},"DOI":"10.1016\/j.healun.2004.05.012","type":"journal-article","created":{"date-parts":[[2005,6,3]],"date-time":"2005-06-03T07:37:00Z","timestamp":1117784220000},"page":"848-853","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":15,"title":["The 6-Minute Walk Test Does Not Reliably Detect Changes in Functional Capacity of Patients Awaiting Cardiac Transplantation"],"prefix":"10.1016","volume":"24","author":[{"given":"Craig","family":"Cheetham","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roger","family":"Taylor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Valerie","family":"Burke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerard","family":"O\u2019Driscoll","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel J.","family":"Green","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.healun.2004.05.012_bib1","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1161\/01.CIR.83.3.778","article-title":"Value of peak exercise oxygen consumption for optimal timing of cardiac transplantation in ambulatory patients with heart failure","volume":"83","author":"Mancini","year":"1991","journal-title":"Circulation"},{"key":"10.1016\/j.healun.2004.05.012_bib2","first-page":"163","article-title":"Improvement in exercise capacity of candidates awaiting heart transplantation","volume":"25","author":"Stevenson","year":"1995","journal-title":"JAMA"},{"key":"10.1016\/j.healun.2004.05.012_bib3","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1161\/01.CIR.99.9.1173","article-title":"Randomised, controlled trial of long-term moderate exercise training in chronic heart failure. Effects on functional capacity, quality of life, and clinical outcome","volume":"99","author":"Belardinelli","year":"1999","journal-title":"Circulation"},{"key":"10.1016\/j.healun.2004.05.012_bib4","first-page":"919","article-title":"The 6-minute walk","volume":"132","author":"Guyatt","year":"1985","journal-title":"Can Med Assoc J"},{"key":"10.1016\/j.healun.2004.05.012_bib5","first-page":"111","article-title":"American Thoracic Society Statement","volume":"166","year":"2002","journal-title":"Am J Crit Care Med"},{"key":"10.1016\/j.healun.2004.05.012_bib6","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1378\/chest.110.2.325","article-title":"The six-minute walk test predicts peak oxygen uptake and survival in patients with advanced heart failure","volume":"110","author":"Cahalin","year":"1996","journal-title":"Chest"},{"key":"10.1016\/j.healun.2004.05.012_bib7","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/S0002-8703(97)70125-X","article-title":"Assessment of oxygen uptake during the six-minute walk test in patients with heart failure","volume":"134","author":"Faggiano","year":"1997","journal-title":"Am Heart J"},{"key":"10.1016\/j.healun.2004.05.012_bib8","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1053\/euhj.1999.1861","article-title":"Is the 6-minute walk test a reliable substitute for peak oxygen uptake in patients with dilated cardiomyopathy?","volume":"21","author":"Zugck","year":"2000","journal-title":"Eur Heart J"},{"key":"10.1016\/j.healun.2004.05.012_bib9","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1053\/euhj.2000.2310","article-title":"Six-minute walking performance in patients with moderate-to-severe heart failure","volume":"22","author":"Opasich","year":"2001","journal-title":"Eur Heart J"},{"key":"10.1016\/j.healun.2004.05.012_bib10","doi-asserted-by":"crossref","first-page":"1702","DOI":"10.1001\/jama.1993.03510140062030","article-title":"Prediction of mortality and morbidity with a 6-minute walk test in patients with left venticular dysfunction. SOLVD Investigators","volume":"270","author":"Bittner","year":"1993","journal-title":"JAMA"},{"key":"10.1016\/j.healun.2004.05.012_bib11","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/S0002-8703(98)70219-4","article-title":"Does the 6-minute walk test predict the prognosis in patients with NYHA class II or III chronic heart failure?","volume":"136","author":"Roul","year":"1998","journal-title":"Am Heart J"},{"key":"10.1016\/j.healun.2004.05.012_bib12","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/0197-2456(90)90005-M","article-title":"Power and sample size calculations","volume":"11","author":"Dupont","year":"1990","journal-title":"Control Clin Trials"},{"key":"10.1016\/j.healun.2004.05.012_bib13","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1053\/euhj.2000.2451","article-title":"The 6-minute walk test and prognosis in chronic heart failure\u2014the available evidence","volume":"22","author":"Sharma","year":"2001","journal-title":"Eur Heart J"},{"key":"10.1016\/j.healun.2004.05.012_bib14","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/S0002-8703(99)70174-2","article-title":"The 6-min walk and peak oxygen consumption in advanced heart failure","volume":"138","author":"Lucas","year":"1999","journal-title":"Am Heart J"},{"key":"10.1016\/j.healun.2004.05.012_bib15","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1053\/euhj.1999.1970","article-title":"The 6-minute walk. A simple test with clinical application","volume":"21","author":"Poole-Wilson","year":"2000","journal-title":"Eur Heart J"},{"key":"10.1016\/j.healun.2004.05.012_bib16","doi-asserted-by":"crossref","first-page":"1607","DOI":"10.1136\/bmj.284.6329.1607","article-title":"Two-, 6-, and 12 minute walking tests in respiratory disease","volume":"284","author":"Butland","year":"1982","journal-title":"BMJ"},{"key":"10.1016\/j.healun.2004.05.012_bib17","first-page":"766","article-title":"Peak exercise oxygen consumption in chronic heart failure","volume":"31","author":"Opasich","year":"1998","journal-title":"JAMA"},{"key":"10.1016\/j.healun.2004.05.012_bib18","doi-asserted-by":"crossref","first-page":"2016","DOI":"10.1183\/09031936.94.07112016","article-title":"Comparison of oxygen uptake during a conventional treadmill test and shuttle walking test in chronic airflow limitation","volume":"7","author":"Singh","year":"1994","journal-title":"Eur Respir J"},{"key":"10.1016\/j.healun.2004.05.012_bib19","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/S1440-2440(01)80038-4","article-title":"A comparison of the shuttle and 6 minute walking tests with measured peak oxygen consumption in patients with heart failure","volume":"4","author":"Green","year":"2001","journal-title":"J Sci Med Sports"}],"container-title":["The Journal of Heart and Lung Transplantation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053249804002876?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053249804002876?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T08:11:14Z","timestamp":1760947874000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053249804002876"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,7]]},"references-count":19,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2005,7]]}},"alternative-id":["S1053249804002876"],"URL":"https:\/\/doi.org\/10.1016\/j.healun.2004.05.012","relation":{},"ISSN":["1053-2498"],"issn-type":[{"value":"1053-2498","type":"print"}],"subject":[],"published":{"date-parts":[[2005,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The 6-Minute Walk Test Does Not Reliably Detect Changes in Functional Capacity of Patients Awaiting Cardiac Transplantation","name":"articletitle","label":"Article Title"},{"value":"The Journal of Heart and Lung Transplantation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.healun.2004.05.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2005 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}