{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T23:03:40Z","timestamp":1793315020696,"version":"4.5.0"},"reference-count":43,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2013,6,1]],"date-time":"2013-06-01T00:00:00Z","timestamp":1370044800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,6,1]],"date-time":"2013-06-01T00:00:00Z","timestamp":1370044800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jhltonline.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Heart and Lung Transplantation"],"published-print":{"date-parts":[[2013,6]]},"DOI":"10.1016\/j.healun.2013.02.010","type":"journal-article","created":{"date-parts":[[2013,3,27]],"date-time":"2013-03-27T01:46:11Z","timestamp":1364348771000},"page":"581-587","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":83,"title":["Defining pulsatility during continuous-flow ventricular assist device support"],"prefix":"10.1016","volume":"32","author":[{"given":"Kevin G.","family":"Soucy","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven C.","family":"Koenig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guruprasad A.","family":"Giridharan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael A.","family":"Sobieski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark S.","family":"Slaughter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.healun.2013.02.010_bib1","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.healun.2011.12.001","article-title":"The Fourth INTERMACS Annual Report: 4,000 implants and counting","volume":"31","author":"Kirklin","year":"2012","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2013.02.010_bib2","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","article-title":"Advanced heart failure treated with continuous-flow left ventricular assist device","volume":"361","author":"Slaughter","year":"2009","journal-title":"N Engl J Med"},{"key":"10.1016\/j.healun.2013.02.010_bib3","doi-asserted-by":"crossref","first-page":"M620","DOI":"10.1097\/00002480-199609000-00062","article-title":"Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings","volume":"42","author":"Bearnson","year":"1996","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib4","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1111\/j.1525-1594.2006.00276.x","article-title":"In vivo assessment of a rotary left ventricular assist device-induced artificial pulse in the proximal and distal aorta","volume":"30","author":"Bourque","year":"2006","journal-title":"Artif Organs"},{"key":"10.1016\/j.healun.2013.02.010_bib5","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1111\/j.1525-1594.2009.00755.x","article-title":"A mathematical model to evaluate control strategies for mechanical circulatory support","volume":"33","author":"Cox","year":"2009","journal-title":"Artif Organs"},{"key":"10.1016\/j.healun.2013.02.010_bib6","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/MAT.0b013e3180536694","article-title":"Design features, developmental status, and experimental results with the Heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor","volume":"53","author":"Farrar","year":"2007","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib7","first-page":"1","article-title":"Flow modulation algorithms for continuous flow left ventricular assist devices to increase vascular pulsatility: a computer simulation study","author":"Ising","year":"2011","journal-title":"Cardiovasc Eng Technol"},{"key":"10.1016\/j.healun.2013.02.010_bib8","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1097\/MAT.0b013e3181dfbab5","article-title":"Design concepts and principle of operation of the HeartWare ventricular assist system","volume":"56","author":"Larose","year":"2010","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib9","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.1016\/j.jtcvs.2010.03.043","article-title":"Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model","volume":"140","author":"Letsou","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.healun.2013.02.010_bib10","first-page":"592","article-title":"Hemodynamic energy generated by a combined centrifugal pump with an intra-aortic balloon pump","volume":"52","author":"Lim","year":"2006","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib11","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/1350-4533(95)00010-0","article-title":"Pulsatile impeller heart: a viable alternative to a problematic diaphragm heart","volume":"18","author":"Qian","year":"1996","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.healun.2013.02.010_bib12","doi-asserted-by":"crossref","first-page":"2621","DOI":"10.1007\/s10439-010-0001-y","article-title":"Numerical modeling of hemodynamics with pulsatile impeller pump support","volume":"38","author":"Shi","year":"2010","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.healun.2013.02.010_bib13","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1097\/MAT.0b013e31819401f9","article-title":"Effects of the pulsatile flow settings on pulsatile waveforms and hemodynamic energy in a PediVAS centrifugal pump","volume":"55","author":"Wang","year":"2009","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib14","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1111\/j.1525-1594.2005.02005.x","article-title":"Benefits of pulsatile flow during and after cardiopulmonary bypass procedures","volume":"29","author":"Undar","year":"2005","journal-title":"Artif Organs"},{"key":"10.1016\/j.healun.2013.02.010_bib15","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1097\/00002480-199911000-00017","article-title":"Pulsatile and nonpulsatile flows can be quantified in terms of energy equivalent pressure during cardiopulmonary bypass for direct comparisons","volume":"45","author":"Undar","year":"1999","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib16","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1097\/01.MAT.0000161944.20233.40","article-title":"Major factors in the controversy of pulsatile versus nonpulsatile flow during acute and chronic cardiac support","volume":"51","author":"Undar","year":"2005","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib17","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.ejcts.2009.05.050","article-title":"Cardiopulmonary bypass with physiological flow and pressure curves: pulse is unnecessary!","volume":"37","author":"Voss","year":"2010","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.healun.2013.02.010_bib18","doi-asserted-by":"crossref","first-page":"III183","DOI":"10.1161\/circ.102.suppl_3.III-183","article-title":"Pulsatile flow in patients with a novel nonpulsatile implantable ventricular assist device","volume":"102","author":"Potapov","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.healun.2013.02.010_bib19","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1111\/j.1525-1594.2010.00996.x","article-title":"Physiologic benefits of pulsatile perfusion during mechanical circulatory support for the treatment of acute and chronic heart failure in adults","volume":"34","author":"Guan","year":"2010","journal-title":"Artif Organs"},{"key":"10.1016\/j.healun.2013.02.010_bib20","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1097\/01.MAT.0000161943.74868.C5","article-title":"Part 1: principles of research on pulsatile and nonpulsatile perfusion during chronic support","volume":"51","author":"Undar","year":"2005","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib21","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1001\/archsurg.1966.01330050034005","article-title":"Energy equivalent pressure","volume":"93","author":"Shepard","year":"1966","journal-title":"Arch Surg"},{"key":"10.1016\/j.healun.2013.02.010_bib22","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1177\/0267659107080115","article-title":"Comparison of perfusion modes on microcirculation during acute and chronic cardiac support: is there a difference?","volume":"22","author":"Ji","year":"2007","journal-title":"Perfusion"},{"key":"10.1016\/j.healun.2013.02.010_bib23","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/01.MAT.0000150326.51377.A0","article-title":"Precise quantification of pressure flow waveforms of a pulsatile ventricular assist device","volume":"51","author":"Undar","year":"2005","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib24","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/01.mat.0000250265.69542.80","article-title":"Quantification of pulsatility as a function of vascular input impedance: an in vitro study","volume":"53","author":"Kaebnick","year":"2007","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib25","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1097\/MAT.0b013e3181e7bf3c","article-title":"Hemodynamic responses to continuous versus pulsatile mechanical unloading of the failing left ventricle","volume":"56","author":"Bartoli","year":"2010","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib26","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1016\/j.jtcvs.2006.09.057","article-title":"Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device","volume":"133","author":"Travis","year":"2007","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.healun.2013.02.010_bib27","doi-asserted-by":"crossref","first-page":"S198","DOI":"10.1097\/00003246-200205001-00005","article-title":"Endothelial responses to mechanical stress: Where is the mechanosensor?","volume":"30","author":"Ali","year":"2002","journal-title":"Crit Care Med"},{"key":"10.1016\/j.healun.2013.02.010_bib28","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1146\/annurev.physiol.59.1.527","article-title":"Spatial relationships in early signaling events of flow-mediated endothelial mechanotransduction","volume":"59","author":"Davies","year":"1997","journal-title":"Annu Rev Physiol"},{"key":"10.1016\/j.healun.2013.02.010_bib29","doi-asserted-by":"crossref","first-page":"32006","DOI":"10.1063\/1.3608137","article-title":"Microfluidic endothelial cell culture model to replicate disturbed flow conditions seen in atherosclerosis susceptible regions","volume":"5","author":"Estrada","year":"2011","journal-title":"Biomicrofluidics"},{"key":"10.1016\/j.healun.2013.02.010_bib30","doi-asserted-by":"crossref","first-page":"3170","DOI":"10.1021\/ac2002998","article-title":"Endothelial cell culture model for replication of physiological profiles of pressure, flow, stretch, and shear stress in vitro","volume":"83","author":"Estrada","year":"2011","journal-title":"Anal Chem"},{"key":"10.1016\/j.healun.2013.02.010_bib31","doi-asserted-by":"crossref","first-page":"1949","DOI":"10.1016\/j.jbiomech.2004.09.030","article-title":"Molecular basis of the effects of shear stress on vascular endothelial cells","volume":"38","author":"Li","year":"2005","journal-title":"J Biomech"},{"key":"10.1016\/j.healun.2013.02.010_bib32","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1159\/000025568","article-title":"Pulsatile stretch and shear stress: physical stimuli determining the production of endothelium-derived relaxing factors","volume":"35","author":"Busse","year":"1998","journal-title":"J Vasc Res"},{"key":"10.1016\/j.healun.2013.02.010_bib33","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1038\/21224","article-title":"Activation of nitric oxide synthase in endothelial cells by Akt-dependent phosphorylation","volume":"399","author":"Dimmeler","year":"1999","journal-title":"Nature"},{"key":"10.1016\/j.healun.2013.02.010_bib34","first-page":"H257","article-title":"Release of endothelium-derived relaxing factor is modulated both by frequency and amplitude of pulsatile flow","volume":"261","author":"Hutcheson","year":"1991","journal-title":"Am J Physiol"},{"key":"10.1016\/j.healun.2013.02.010_bib35","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1046\/j.1525-1594.1999.06411.x","article-title":"Augmentative effect of pulsatility on the wall shear stress in tube flow","volume":"23","author":"Nakata","year":"1999","journal-title":"Artif Organs"},{"key":"10.1016\/j.healun.2013.02.010_bib36","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1007\/s12265-012-9360-0","article-title":"We always need a pulse, or do we??","volume":"5","author":"Miller","year":"2012","journal-title":"J Cardiovasc Transl Res"},{"key":"10.1016\/j.healun.2013.02.010_bib37","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/S0003-4975(01)02644-3","article-title":"Impacts of pulsatile systemic circulation on endothelium-derived nitric oxide release in anesthetized dogs","volume":"72","author":"Nakano","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.healun.2013.02.010_bib38","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1097\/01.MAT.0000129320.57362.db","article-title":"Microcirculation of the bulbar conjunctiva in the goat implanted with a total artificial heart: effects of pulsatile and nonpulsatile flow","volume":"50","author":"Baba","year":"2004","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib39","doi-asserted-by":"crossref","first-page":"M724","DOI":"10.1097\/00002480-199609000-00083","article-title":"The role of pulsatility in end-organ microcirculation after cardiogenic shock","volume":"42","author":"Orime","year":"1996","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib40","doi-asserted-by":"crossref","first-page":"M657","DOI":"10.1097\/00002480-199703000-00174","article-title":"Pulmonary microcirculation during pulsatile and non pulsatile perfusion","volume":"43","author":"Konishi","year":"1997","journal-title":"Asaio J"},{"key":"10.1016\/j.healun.2013.02.010_bib41","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1006\/mvre.1994.1058","article-title":"Evaluation of pulsatile and nonpulsatile flow in capillaries of goat skeletal muscle using intravital microscopy","volume":"48","author":"Lee","year":"1994","journal-title":"Microvasc Res"},{"key":"10.1016\/j.healun.2013.02.010_bib42","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1046\/j.1525-1594.1999.06318.x","article-title":"Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation","volume":"23","author":"Sezai","year":"1999","journal-title":"Artif Organs"},{"key":"10.1016\/j.healun.2013.02.010_bib43","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1016\/S0003-4975(03)00724-0","article-title":"Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months","volume":"76","author":"Letsou","year":"2003","journal-title":"Ann Thorac Surg"}],"container-title":["The Journal of Heart and Lung Transplantation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053249813011510?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053249813011510?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T08:25:46Z","timestamp":1760948746000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053249813011510"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,6]]},"references-count":43,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2013,6]]}},"alternative-id":["S1053249813011510"],"URL":"https:\/\/doi.org\/10.1016\/j.healun.2013.02.010","relation":{},"ISSN":["1053-2498"],"issn-type":[{"value":"1053-2498","type":"print"}],"subject":[],"published":{"date-parts":[[2013,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Defining pulsatility during continuous-flow ventricular assist device support","name":"articletitle","label":"Article Title"},{"value":"The Journal of Heart and Lung Transplantation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.healun.2013.02.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}