{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T05:33:43Z","timestamp":1788413623589,"version":"build-2803163510"},"reference-count":17,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jhltonline.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Heart and Lung Transplantation"],"published-print":{"date-parts":[[2017,1]]},"DOI":"10.1016\/j.healun.2016.07.018","type":"journal-article","created":{"date-parts":[[2016,7,29]],"date-time":"2016-07-29T18:37:45Z","timestamp":1469817465000},"page":"91-96","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":51,"title":["Aortic insufficiency in continuous-flow left ventricular assist device support patients is common but does not impact long-term mortality"],"prefix":"10.1016","volume":"36","author":[{"given":"Christopher T.","family":"Holley","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Megan","family":"Fitzpatrick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samit S.","family":"Roy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. Chadi","family":"Alraies","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rebecca","family":"Cogswell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Souslian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Eckman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ranjit","family":"John","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.healun.2016.07.018_bib1","first-page":"547","article-title":"Durability of continuous-flow left ventricular assist devices: a systematic review","volume":"3","author":"Xie","year":"2014","journal-title":"Ann Cardiothorac Surg"},{"key":"10.1016\/j.healun.2016.07.018_bib2","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.athoracsur.2012.09.020","article-title":"The development of aortic insufficiency in continuous-flow left ventricular assist device-supported patients","volume":"95","author":"Aggarwal","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.healun.2016.07.018_bib3","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1161\/CIRCHEARTFAILURE.109.917765","article-title":"The development of aortic insufficiency in left ventricular assist device-supported patients","volume":"3","author":"Cowger","year":"2010","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.healun.2016.07.018_bib4","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1016\/j.healun.2014.06.008","article-title":"Consequences of aortic insufficiency during long-term axial continuous-flow left ventricular assist device support","volume":"33","author":"Cowger","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2016.07.018_bib5","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1161\/CIRCHEARTFAILURE.113.000878","article-title":"Prevalence, significance, and management of aortic insufficiency in continuous flow left ventricular assist device recipients","volume":"7","author":"Jorde","year":"2014","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.healun.2016.07.018_bib6","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/S0735-1097(00)00744-0","article-title":"Prevalence and correlates of aortic regurgitation in American Indians: the Strong Heart Study","volume":"36","author":"Lebowitz","year":"2000","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.healun.2016.07.018_bib7","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1016\/j.healun.2008.05.029","article-title":"Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device","volume":"27","author":"Mudd","year":"2008","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2016.07.018_bib8","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1016\/j.healun.2010.05.018","article-title":"Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices","volume":"29","author":"Pak","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2016.07.018_bib9","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1016\/j.athoracsur.2014.05.030","article-title":"De novo aortic regurgitation after continuous-flow left ventricular assist device implantation","volume":"98","author":"Patil","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.healun.2016.07.018_bib10","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1016\/j.jtcvs.2012.11.066","article-title":"Natural history and clinical effect of aortic valve regurgitation after left ventricular assist device implantation","volume":"145","author":"Rajagopal","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.healun.2016.07.018_bib11","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1067\/mtc.2001.114770","article-title":"Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: signs, symptoms, and concerns","volume":"122","author":"Samuels","year":"2001","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.healun.2016.07.018_bib12","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1016\/j.healun.2010.06.006","article-title":"Aortic valve pathophysiology during left ventricular assist device support","volume":"29","author":"John","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2016.07.018_bib13","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/S0894-7317(03)00335-3","article-title":"Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography","volume":"16","author":"Zoghbi","year":"2003","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.healun.2016.07.018_bib14","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/01.mat.0000201961.97981.e9","article-title":"Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta","volume":"52","author":"May-Newman","year":"2006","journal-title":"ASAIO J"},{"key":"10.1016\/j.healun.2016.07.018_bib15","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/S1053-2498(00)00396-X","article-title":"Aortic valve stenosis induced by left ventricular assist device (LVAD)","volume":"20","author":"Rose","year":"2001","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2016.07.018_bib16","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1093\/ejcts\/ezv221","article-title":"Does postoperative blood pressure influence development of aortic regurgitation following continuous-flow left ventricular assist device implantation?","volume":"49","author":"Patil","year":"2016","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.healun.2016.07.018_bib17","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.jcin.2012.08.021","article-title":"Percutaneous transcatheter aortic valve closure successfully treats left ventricular assist device-associated aortic insufficiency and improves cardiac hemodynamics","volume":"6","author":"Parikh","year":"2013","journal-title":"JACC Cardiovasc Interv"}],"container-title":["The Journal of Heart and Lung Transplantation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053249816302583?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053249816302583?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T08:33:01Z","timestamp":1760949181000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053249816302583"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["S1053249816302583"],"URL":"https:\/\/doi.org\/10.1016\/j.healun.2016.07.018","relation":{},"ISSN":["1053-2498"],"issn-type":[{"value":"1053-2498","type":"print"}],"subject":[],"published":{"date-parts":[[2017,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Aortic insufficiency in continuous-flow left ventricular assist device support patients is common but does not impact long-term mortality","name":"articletitle","label":"Article Title"},{"value":"The Journal of Heart and Lung Transplantation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.healun.2016.07.018","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}