{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,15]],"date-time":"2026-11-15T05:01:45Z","timestamp":1794718905085,"version":"4.9.1"},"reference-count":33,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100017483","name":"Harry S. Moss Heart Trust","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100017483","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000050","name":"National Heart, Lung, and Blood Institute","doi-asserted-by":"publisher","award":["1K23HLI32048-01"],"award-info":[{"award-number":["1K23HLI32048-01"]}],"id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000968","name":"American Heart Association","doi-asserted-by":"publisher","award":["18POST33960092"],"award-info":[{"award-number":["18POST33960092"]}],"id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006108","name":"National Center for Advancing Translational Sciences","doi-asserted-by":"publisher","award":["1TR002535"],"award-info":[{"award-number":["1TR002535"]}],"id":[{"id":"10.13039\/100006108","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100014450","name":"Anschutz Medical Campus, University of Colorado","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100014450","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","jhltonline.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Heart and Lung Transplantation"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1016\/j.healun.2020.11.009","type":"journal-article","created":{"date-parts":[[2020,11,22]],"date-time":"2020-11-22T10:04:20Z","timestamp":1606039460000},"page":"128-137","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":47,"title":["Right ventricular function and cardiopulmonary performance among patients with heart failure supported by durable mechanical circulatory support devices"],"prefix":"10.1016","volume":"40","author":[{"given":"Tomio","family":"Tran","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akshay","family":"Muralidhar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kendall","family":"Hunter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cullen","family":"Buchanan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Greg","family":"Coe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michinari","family":"Hieda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christine","family":"Tompkins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Zipse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melanie J.","family":"Spotts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephanie G.","family":"Laing","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristina","family":"Fosmark","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jordan","family":"Hoffman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amrut V.","family":"Ambardekar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eugene E.","family":"Wolfel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justin","family":"Lawley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Levine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wendy M.","family":"Kohrt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay","family":"Pal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"III","given":"William K.","family":"Cornwell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.healun.2020.11.009_bib0001","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.1056\/NEJMoa1800866","article-title":"Two-year outcomes with a magnetically levitated cardiac pump in heart failure","volume":"378","author":"Mehra","year":"2018","journal-title":"N Engl J Med"},{"key":"10.1016\/j.healun.2020.11.009_bib0002","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1056\/NEJMoa1602954","article-title":"Intrapericardial left ventricular assist device for advanced heart failure","volume":"376","author":"Rogers","year":"2017","journal-title":"N Engl J Med"},{"key":"10.1016\/j.healun.2020.11.009_bib0003","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1161\/STROKEAHA.118.022967","article-title":"Stroke incidence and impact of continuous-flow left ventricular assist devices on cerebrovascular physiology","volume":"50","author":"Cornwell","year":"2019","journal-title":"Stroke"},{"key":"10.1016\/j.healun.2020.11.009_bib0004","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.healun.2018.11.013","article-title":"The Society of Thoracic Surgeons INTERMACS database annual report: evolving indications, outcomes, and scientific partnerships","volume":"38","author":"Kormos","year":"2019","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2020.11.009_bib0005","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.1016\/j.healun.2017.07.005","article-title":"Eighth annual INTERMACS report: special focus on framing the impact of adverse events","volume":"36","author":"Kirklin","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2020.11.009_bib0006","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1161\/CIRCIMAGING.113.001127","article-title":"Assessment of right ventricular function in left ventricular assist device candidates","volume":"7","author":"Hayek","year":"2014","journal-title":"Circ Cardiovasc Imaging"},{"key":"10.1016\/j.healun.2020.11.009_bib0007","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1016\/j.healun.2015.06.015","article-title":"Right ventricular failure after left ventricular assist devices","volume":"34","author":"Lampert","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2020.11.009_bib0008","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/j.echo.2015.05.008","article-title":"Echocardiography in the management of patients with left ventricular assist devices: recommendations from the American Society of Echocardiography","volume":"28","author":"Stainback","year":"2015","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.healun.2020.11.009_bib0009","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1161\/CIRCHEARTFAILURE.112.000008","article-title":"Right ventricular dysfunction in systemic sclerosis-associated pulmonary arterial hypertension","volume":"6","author":"Tedford","year":"2013","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.healun.2020.11.009_bib0010","doi-asserted-by":"crossref","first-page":"2413","DOI":"10.1161\/CIRCULATIONAHA.116.022082","article-title":"Right ventricular functional reserve in pulmonary arterial hypertension","volume":"133","author":"Hsu","year":"2016","journal-title":"Circulation"},{"key":"10.1016\/j.healun.2020.11.009_bib0011","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCHEARTFAILURE.117.004121","article-title":"Load-independent systolic and diastolic right ventricular function in heart failure with preserved ejection fraction as assessed by resting and handgrip exercise pressure-volume loops","volume":"11","author":"Rommel","year":"2018","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.healun.2020.11.009_bib0012","doi-asserted-by":"crossref","first-page":"2575","DOI":"10.1113\/JP279759","article-title":"New insights into resting and exertional right ventricular performance in the healthy heart through real-time pressure-volume analysis","volume":"598","author":"Cornwell","year":"2020","journal-title":"J Physiol"},{"key":"10.1016\/j.healun.2020.11.009_bib0013","doi-asserted-by":"crossref","first-page":"2575","DOI":"10.1113\/JP279759","article-title":"New insights into right ventricular performance during exercise using high-fidelity conductance catheters to generate pressure volume loops","volume":"598","author":"Cornwell","year":"2020","journal-title":"J Physiol"},{"key":"10.1016\/j.healun.2020.11.009_bib0014","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jchf.2015.10.001","article-title":"Hemodynamic ramp tests in patients with left ventricular assist devices","volume":"4","author":"Uriel","year":"2016","journal-title":"JACC Heart Fail"},{"key":"10.1016\/j.healun.2020.11.009_bib0015","first-page":"192","article-title":"Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure-volume relationships in man","volume":"15","author":"Kass","year":"1988","journal-title":"Cathet Cardiovasc Diagn"},{"key":"10.1016\/j.healun.2020.11.009_bib0016","first-page":"1","article-title":"Cardiac pressure-volume loop analysis using conductance catheters in mice","volume":"103","author":"Abraham","year":"2015","journal-title":"J Vis Exp"},{"key":"10.1016\/j.healun.2020.11.009_bib0017","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1093\/cvr\/15.6.328","article-title":"Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter","volume":"15","author":"Baan","year":"1981","journal-title":"Cardiovasc Res"},{"key":"10.1016\/j.healun.2020.11.009_bib0018","doi-asserted-by":"crossref","first-page":"H534","DOI":"10.1152\/ajpheart.01268.2006","article-title":"Left ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibration","volume":"293","author":"Nielsen","year":"2007","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"10.1016\/j.healun.2020.11.009_bib0019","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/BF02513284","article-title":"Parallel conductance determination in cardiac volumetry using dilution manoeuvres: theoretical analysis and practical implications","volume":"37","author":"Herrera","year":"1999","journal-title":"Med Biol Eng Comput"},{"key":"10.1016\/j.healun.2020.11.009_bib0020","doi-asserted-by":"crossref","first-page":"H1625","DOI":"10.1152\/ajpheart.01023.2002","article-title":"Single-beat estimation of right ventricular end-systolic pressure-volume relationship","volume":"284","author":"Brimioulle","year":"2003","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"10.1016\/j.healun.2020.11.009_bib0021","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1161\/01.CIR.83.1.202","article-title":"Single-beat estimation of the slope of the end-systolic pressure-volume relation in the human left ventricle","volume":"83","author":"Takeuchi","year":"1991","journal-title":"Circulation"},{"key":"10.1016\/j.healun.2020.11.009_bib0022","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1161\/01.CIR.77.5.1116","article-title":"Efficiency of energy transfer from pressure-volume area to external mechanical work increases with contractile state and decreases with afterload in the left ventricle of the anesthetized closed-chest dog","volume":"5","author":"Nozawa","year":"1988","journal-title":"Circulation"},{"key":"10.1016\/j.healun.2020.11.009_bib0023","unstructured":"Centers for Disease Control and Prevention. Perceived exertion (borg rating of perceived exertion scale). Available at: https:\/\/www.cdc.gov\/physicalactivity\/basics\/measuring\/exertion.htm."},{"key":"10.1016\/j.healun.2020.11.009_bib0024","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.healun.2016.07.008","article-title":"Clinical hemodynamic evaluation of patients implanted with a fully magnetically levitated left ventricular assist device (HeartMate 3)","volume":"36","author":"Uriel","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2020.11.009_bib0025","doi-asserted-by":"crossref","first-page":"1826","DOI":"10.1016\/j.jacc.2009.12.052","article-title":"Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients","volume":"55","author":"Rogers","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.healun.2020.11.009_bib0026","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.healun.2014.11.001","article-title":"Exercise in heart failure patients supported with a left ventricular assist device","volume":"34","author":"Jung","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.healun.2020.11.009_bib0027","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1002\/ejhf.52","article-title":"Effect of increasing pump speed during exercise on peak oxygen uptake in heart failure patients supported with a continuous-flow left ventricular assist device","volume":"16","author":"Jung","year":"2014","journal-title":"A double-blind randomized study. Eur J Heart Fail"},{"key":"10.1016\/j.healun.2020.11.009_bib0028","series-title":"Human circulation, regulation during physical stress","author":"Rowell","year":"1986"},{"key":"10.1016\/j.healun.2020.11.009_bib0029","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1152\/jappl.1998.84.2.599","article-title":"Influence of age and gender on cardiac output-VO2 relationships during submaximal cycle ergometry","volume":"84","author":"Proctor","year":"1998","journal-title":"J Appl Physiol"},{"key":"10.1016\/j.healun.2020.11.009_bib0030","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1249\/00005768-199409000-00008","article-title":"Endurance athletes\u2019 stroke volume does not plateau: major advantage is diastolic function","volume":"26","author":"Gledhill","year":"1994","journal-title":"Med Sci Sports Exerc"},{"key":"10.1016\/j.healun.2020.11.009_bib0031","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1164\/rccm.201412-2271OC","article-title":"The effects of exercise on right ventricular contractility and right ventricular-arterial coupling in pulmonary hypertension","volume":"191","author":"Spruijt","year":"2015","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1016\/j.healun.2020.11.009_bib0032","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1152\/japplphysiol.01123.2013","article-title":"Right ventricular dysfunction in chronic thromboembolic obstruction of the pulmonary artery: a pressure-volume study using the conductance catheter","volume":"116","author":"McCabe","year":"2014","journal-title":"J Appl Physiol (1985)"},{"key":"10.1016\/j.healun.2020.11.009_bib0033","doi-asserted-by":"crossref","first-page":"1886","DOI":"10.1097\/01.CCM.0000139607.38497.8A","article-title":"Comparison between single-beat and multiple-beat methods for estimation of right ventricular contractility","volume":"32","author":"Lambermont","year":"2004","journal-title":"Crit Care Med"}],"container-title":["The Journal of Heart and Lung Transplantation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053249820318416?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1053249820318416?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T15:13:12Z","timestamp":1762355592000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053249820318416"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2]]},"references-count":33,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["S1053249820318416"],"URL":"https:\/\/doi.org\/10.1016\/j.healun.2020.11.009","relation":{},"ISSN":["1053-2498"],"issn-type":[{"value":"1053-2498","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Right ventricular function and cardiopulmonary performance among patients with heart failure supported by durable mechanical circulatory support devices","name":"articletitle","label":"Article Title"},{"value":"The Journal of Heart and Lung Transplantation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.healun.2020.11.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 International Society for Heart and Lung Transplantation. All rights reserved.","name":"copyright","label":"Copyright"}]}}