{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T22:18:39Z","timestamp":1791238719470,"version":"4.1.0"},"reference-count":57,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2022,8,1]],"date-time":"2022-08-01T00:00:00Z","timestamp":1659312000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,8,1]],"date-time":"2022-08-01T00:00:00Z","timestamp":1659312000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,4,19]],"date-time":"2022-04-19T00:00:00Z","timestamp":1650326400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Hearing Research"],"published-print":{"date-parts":[[2022,8]]},"DOI":"10.1016\/j.heares.2022.108503","type":"journal-article","created":{"date-parts":[[2022,4,3]],"date-time":"2022-04-03T17:18:51Z","timestamp":1649006331000},"page":"108503","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"special_numbering":"C","title":["Long-term follow-up and review of the Bone Conduction Implant"],"prefix":"10.1016","volume":"421","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2329-8706","authenticated-orcid":false,"given":"Sabine","family":"Reinfeldt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M\u00e5ns","family":"Eeg-Olofsson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl-Johan","family":"Fred\u00e9n Jansson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9067-1091","authenticated-orcid":false,"given":"Ann-Charlotte","family":"Persson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"H\u00e5kansson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"9","key":"10.1016\/j.heares.2022.108503_bib0001","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1080\/14992027.2018.1470337","article-title":"Horizontal sound localisation accuracy in individuals with conductive hearing loss: effect of the bone conduction implant","volume":"57","author":"Asp","year":"2018","journal-title":"Int. J. Audiol."},{"issue":"2","key":"10.1016\/j.heares.2022.108503_bib0002","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1097\/00003446-199504000-00005","article-title":"The abbreviated profile of hearing aid benefit","volume":"16","author":"Cox","year":"1995","journal-title":"Ear Hear."},{"key":"10.1016\/j.heares.2022.108503_bib0003","doi-asserted-by":"crossref","DOI":"10.1007\/s00405-022-07265-2","article-title":"Evaluation of the Bonebridge BCI 602 active bone conduction implant in adults: efficacy and stability of audiological, surgical, and functional outcomes","author":"Cywka","year":"2022","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"10.1016\/j.heares.2022.108503_bib0004","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.heares.2018.10.003","article-title":"Performance evaluation of a novel peizoelectric subcutaneous bone conduction device","volume":"370","author":"Dobrev","year":"2018","journal-title":"Hear. Res."},{"issue":"6","key":"10.1016\/j.heares.2022.108503_bib0005","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1097\/MAO.0b013e3182267e9c","article-title":"Stability, survival, and tolerability of a novel baha implant system: six-month data from a multicenter clinical investigation","volume":"32","author":"Dun","year":"2011","journal-title":"Otol. Neurotol."},{"issue":"4","key":"10.1016\/j.heares.2022.108503_bib0006","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1097\/MAO.0000000000000203","article-title":"The bone conduction implant\u2013first implantation, surgical and audiologic aspects","volume":"35","author":"Eeg-Olofsson","year":"2014","journal-title":"Otol. Neurotol."},{"key":"10.1016\/j.heares.2022.108503_bib0007","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1159\/000369918","article-title":"Evaluation of Bone Tissue Formation in a Flat Surface Attachment of a Bone Conduction Implant: a Pilot Study in a Sheep Model","volume":"4","author":"Eeg-Olofsson","year":"2014","journal-title":"Audiol. Neurotol. Extra"},{"key":"10.1016\/j.heares.2022.108503_bib0008","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.heares.2013.08.015","article-title":"Transmission of bone conducted sound - correlation between hearing perception and cochlear vibration","volume":"306","author":"Eeg-Olofsson","year":"2013","journal-title":"Hear. Res."},{"key":"10.1016\/j.heares.2022.108503_bib0009","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1097\/MAO.0b013e3182009f16","article-title":"Implications for contralateral bone-conducted transmission as measured by cochlear vibrations","volume":"32","author":"Eeg-Olofsson","year":"2011","journal-title":"Otol. Neurotol."},{"issue":"12","key":"10.1016\/j.heares.2022.108503_bib0010","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1080\/14992020802311216","article-title":"Transmission of bone-conducted sound in the human skull measured by cochlear vibrations","volume":"47","author":"Eeg-Olofsson","year":"2008","journal-title":"Int. J. Audiol."},{"key":"10.1016\/j.heares.2022.108503_bib0011","first-page":"413","article-title":"Magnetic resonance imaging investigation of the bone conduction implant - a pilot study at 1.5","volume":"8","author":"Fred\u00e9n Jansson","year":"2015","journal-title":"Tesla. Med Devices (Auckl)"},{"issue":"6","key":"10.1016\/j.heares.2022.108503_bib0012","doi-asserted-by":"crossref","first-page":"1887","DOI":"10.1109\/TBME.2014.2309978","article-title":"MRI induced torque and demagnetization in retention magnets for a bone conduction implant","volume":"61","author":"Fred\u00e9n Jansson","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.heares.2022.108503_bib0013","first-page":"89","article-title":"Robustness and lifetime of the bone conduction implant - a pilot study","volume":"12","author":"Fred\u00e9n Jansson","year":"2019","journal-title":"Med Devices (Auckl)"},{"key":"10.1016\/j.heares.2022.108503_bib0014","article-title":"The evaluation of a surgery and the short-term benefits of a new active bone conduction hearing implant - the Osia\u00ae","author":"Gawecki","year":"2020","journal-title":"Braz J Otorhinolaryngol"},{"issue":"3","key":"10.1016\/j.heares.2022.108503_bib0015","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1080\/00016489.2019.1691744","article-title":"Clinical performance of the Osia system, a new active osseointegrated implant system. Results from a prospective clinical investigation","volume":"140","author":"Goycoolea","year":"2020","journal-title":"Acta Otolaryngol."},{"issue":"1","key":"10.1016\/j.heares.2022.108503_bib0016","doi-asserted-by":"crossref","first-page":"71","DOI":"10.3109\/01050399509042213","article-title":"Efficient adaptive methods for measuring speech reception threshold in quiet and in noise","volume":"24","author":"Hagerman","year":"1995","journal-title":"Scand. Audiol."},{"issue":"6","key":"10.1016\/j.heares.2022.108503_bib0017","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1097\/AUD.0000000000000572","article-title":"Development of a novel bone conduction verification tool using a surface microphone: validation with percutaneous bone conduction users","volume":"39","author":"Hodgetts","year":"2018","journal-title":"Ear Hear."},{"issue":"7","key":"10.1016\/j.heares.2022.108503_bib0018","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1097\/MAO.0b013e31822a1c47","article-title":"Outcome of the bone-anchored hearing aid procedure without skin thinning: a prospective clinical trial","volume":"32","author":"Hultcrantz","year":"2011","journal-title":"Otol. Neurotol."},{"issue":"8","key":"10.1016\/j.heares.2022.108503_bib0019","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.1097\/MAO.0000000000000352","article-title":"A five-year follow-up on the osseointegration of bone-anchored hearing device implantation without tissue reduction","volume":"35","author":"Hultcrantz","year":"2014","journal-title":"Otol. Neurotol."},{"issue":"8","key":"10.1016\/j.heares.2022.108503_bib0020","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1097\/MAO.0b013e31816fdc90","article-title":"Percutaneous versus transcutaneous bone conduction implant system: a feasibility study on a cadaver head","volume":"29","author":"H\u00e5kansson","year":"2008","journal-title":"Otol. Neurotol."},{"issue":"3","key":"10.1016\/j.heares.2022.108503_bib0021","doi-asserted-by":"crossref","first-page":"203","DOI":"10.3109\/14992020903264462","article-title":"A novel bone conduction implant (BCI): engineering aspects and pre-clinical studies","volume":"49","author":"H\u00e5kansson","year":"2010","journal-title":"Int. J. Audiol."},{"issue":"12","key":"10.1016\/j.heares.2022.108503_bib0022","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1080\/14992027.2019.1657243","article-title":"The bone conduction implant - a review and 1-year follow-up","volume":"58","author":"H\u00e5kansson","year":"2019","journal-title":"Int. J. Audiol."},{"issue":"3\u20134","key":"10.1016\/j.heares.2022.108503_bib0023","doi-asserted-by":"crossref","first-page":"229","DOI":"10.3109\/00016488509104785","article-title":"The bone-anchored hearing aid. Principal design and a psychoacoustical evaluation","volume":"100","author":"H\u00e5kansson","year":"1985","journal-title":"Acta Otolaryngol."},{"issue":"2","key":"10.1016\/j.heares.2022.108503_bib0024","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1121\/1.1536633","article-title":"The balanced electromagnetic separation transducer a new bone conduction transducer","volume":"113","author":"H\u00e5kansson","year":"2003","journal-title":"J. Acoust. Soc. Am."},{"key":"10.1016\/j.heares.2022.108503_bib0025","series-title":"Acoustics \u2013 Audiometric Test Methods \u2013 Part 1: Puretone Air and Bone Conduction Audiometry","year":"2010"},{"key":"10.1016\/j.heares.2022.108503_bib0026","series-title":"Acoustics \u2013 Audiometric Test Methods \u2013 Part 3: Speech Audiometry","year":"2012"},{"issue":"2","key":"10.1016\/j.heares.2022.108503_bib0027","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/S0901-5027(05)80837-9","article-title":"Influence of implant diameters on the integration of screw implants. An experimental study in rabbits","volume":"26","author":"Ivanoff","year":"1997","journal-title":"Int. J. Oral Maxillofac. Surg."},{"issue":"5","key":"10.1016\/j.heares.2022.108503_bib0028","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1111\/coa.13556","article-title":"Ten years of experience with the Ponto bone-anchored hearing system-a systematic literature review","volume":"45","author":"Lagerkvist","year":"2020","journal-title":"Clin. Otolaryngol."},{"issue":"11","key":"10.1016\/j.heares.2022.108503_bib0029","doi-asserted-by":"crossref","first-page":"2995","DOI":"10.1007\/s00405-020-06022-7","article-title":"First United Kingdom experience of the novel Osia active transcutaneous piezoelectric bone conduction implant","volume":"277","author":"Lau","year":"2020","journal-title":"Eur. Arch. Otorhinolaryngol."},{"issue":"9","key":"10.1016\/j.heares.2022.108503_bib0030","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0221484","article-title":"Active transcutaneous bone conduction hearing implants: systematic review and meta-analysis","volume":"14","author":"Magele","year":"2019","journal-title":"PLoS ONE"},{"issue":"5","key":"10.1016\/j.heares.2022.108503_bib0031","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1097\/MAO.0000000000000765","article-title":"Long-term compliance and satisfaction with percutaneous bone conduction devices in patients with congenital unilateral conductive hearing loss","volume":"36","author":"Nelissen","year":"2015","journal-title":"Otol. Neurotol."},{"issue":"5","key":"10.1016\/j.heares.2022.108503_bib0032","first-page":"S515","article-title":"Titanium oral implants: surface characteristics, interface biology and clinical outcome","volume":"7","author":"Palmquist","year":"2010","journal-title":"J. R. Soc. Interface"},{"issue":"5","key":"10.1016\/j.heares.2022.108503_bib0033","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1159\/000506588","article-title":"Three-year follow-up with the bone conduction implant","volume":"25","author":"Persson","year":"2020","journal-title":"Audiol. Neurootol."},{"key":"10.1016\/j.heares.2022.108503_bib0034","article-title":"A novel method for objective in-situ measurement of audibility in bone conduction hearing devices \u2013 a pilot study using a skin drive BCD","author":"Persson","year":"2022","journal-title":"Int. J. Audiol."},{"key":"10.1016\/j.heares.2022.108503_bib0035","doi-asserted-by":"crossref","DOI":"10.1097\/MAO.0000000000003116","article-title":"Clinical performance assessment of a new active osseointegrated implant system in mixed hearing loss: results from a prospective clinical investigation","author":"Pla-Gil","year":"2021","journal-title":"Otol. Neurotol."},{"key":"10.1016\/j.heares.2022.108503_bib0036","article-title":"Long-term data of the new transcutaneous partially implantable bone conduction hearing system Osia\u00ae","author":"Rauch","year":"2021","journal-title":"Eur. Arch. Otorhinolaryngol."},{"issue":"6","key":"10.1016\/j.heares.2022.108503_bib0037","doi-asserted-by":"crossref","first-page":"360","DOI":"10.3109\/14992027.2014.880813","article-title":"Bone conduction hearing sensitivity in normal-hearing subjects: transcutaneous stimulation at BAHA vs BCI position","volume":"53","author":"Reinfeldt","year":"2014","journal-title":"Int. J. Audiol."},{"key":"10.1016\/j.heares.2022.108503_bib0038","first-page":"79","article-title":"New developments in bone-conduction hearing implants: a review","volume":"8","author":"Reinfeldt","year":"2015","journal-title":"Med Devices (Auckl)"},{"issue":"4","key":"10.1016\/j.heares.2022.108503_bib0039","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1097\/MAO.0000000000000682","article-title":"Study of the feasible size of a bone conduction implant transducer in the temporal bone","volume":"36","author":"Reinfeldt","year":"2015","journal-title":"Otol. Neurotol."},{"issue":"6","key":"10.1016\/j.heares.2022.108503_bib0040","doi-asserted-by":"crossref","first-page":"408","DOI":"10.3109\/14992027.2014.996826","article-title":"The bone conduction implant: clinical results of the first six patients","volume":"54","author":"Reinfeldt","year":"2015","journal-title":"Int. J. Audiol."},{"key":"10.1016\/j.heares.2022.108503_bib0041","first-page":"193","article-title":"Nasal sound pressure as objective verification of implant in active transcutaneous bone conduction devices","volume":"12","author":"Reinfeldt","year":"2019","journal-title":"Med Devices (Auckl)"},{"issue":"5","key":"10.1016\/j.heares.2022.108503_bib0042","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1080\/14992027.2019.1705406","article-title":"The effect of an active transcutaneous bone conduction device on spatial release from masking","volume":"59","author":"Rigato","year":"2020","journal-title":"Int. J. Audiol."},{"issue":"9","key":"10.1016\/j.heares.2022.108503_bib0043","doi-asserted-by":"crossref","first-page":"1381","DOI":"10.1097\/MAO.0000000000001183","article-title":"Audiometric comparison between the first patients with the transcutaneous bone conduction implant and matched percutaneous bone anchored hearing device users","volume":"37","author":"Rigato","year":"2016","journal-title":"Otol. Neurotol."},{"key":"10.1016\/j.heares.2022.108503_bib0044","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.heares.2018.01.007","article-title":"Direct bone conduction stimulation: ipsilateral effect of different transducer attachments in active transcutaneous devices","volume":"361","author":"Rigato","year":"2018","journal-title":"Hear. Res."},{"key":"10.1016\/j.heares.2022.108503_bib0045","doi-asserted-by":"crossref","DOI":"10.1016\/j.heares.2019.06.006","article-title":"Effect of transducer attachment on vibration transmission and transcranial attenuation for direct drive bone conduction stimulation","volume":"381","author":"Rigato","year":"2019","journal-title":"Hear. Res."},{"issue":"6","key":"10.1016\/j.heares.2022.108503_bib57","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1177\/000348949610500601","article-title":"Measuring patient benefit from otorhinolaryngological surgery and therapy","volume":"105","author":"Robinson","year":"1996","journal-title":"Ann. Otol. Rhinol. Laryngol."},{"issue":"6","key":"10.1016\/j.heares.2022.108503_bib0046","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1097\/MAO.0000000000003159","article-title":"Long-term, multicenter results with the first transcutaneous bone conduction implant","volume":"42","author":"Sprinzl","year":"2021","journal-title":"Otol. Neurotol."},{"key":"10.1016\/j.heares.2022.108503_bib0047","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1097\/MAO.0b013e31823e28ab","article-title":"Transcranial attenuation of bone-conducted sound when stimulation is at the mastoid and at the bone conduction hearing aid position","volume":"33","author":"Stenfelt","year":"2012","journal-title":"Otol. Neurotol."},{"issue":"6","key":"10.1016\/j.heares.2022.108503_bib0048","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1097\/01.mao.0000187236.10842.d5","article-title":"Bone-conducted sound: physiological and clinical aspects","volume":"26","author":"Stenfelt","year":"2005","journal-title":"Otol. Neurotol."},{"issue":"4","key":"10.1016\/j.heares.2022.108503_bib0049","doi-asserted-by":"crossref","first-page":"2373","DOI":"10.1121\/1.2005847","article-title":"Transmission properties of bone conducted sound: measurements in cadaver heads","volume":"118","author":"Stenfelt","year":"2005","journal-title":"J. Acoust. Soc. Am."},{"issue":"10","key":"10.1016\/j.heares.2022.108503_bib0050","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1080\/14992020701545880","article-title":"A model of the occlusion effect with bone-conducted stimulation","volume":"46","author":"Stenfelt","year":"2007","journal-title":"Int. J. Audiol."},{"issue":"4","key":"10.1016\/j.heares.2022.108503_bib0051","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1097\/MAO.0b013e3182877aee","article-title":"A vibration investigation of a flat surface contact to skull bone for direct bone conduction transmission in sheep skulls in vivo","volume":"34","author":"Taghavi","year":"2013","journal-title":"Otol. Neurotol."},{"key":"10.1016\/j.heares.2022.108503_bib0052","series-title":"IASTED International Conference Biomedical Engineering (BioMed 2012), Innsbruck, Austria","article-title":"A novel bone conduction implant - analog radio frequency data and power link design","author":"Taghavi","year":"2012"},{"issue":"11","key":"10.1016\/j.heares.2022.108503_bib0053","doi-asserted-by":"crossref","first-page":"3050","DOI":"10.1109\/TBME.2012.2213252","article-title":"Analysis and design of RF power and data link using amplitude modulation of Class-E for a novel bone conduction implant","volume":"59","author":"Taghavi","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"3","key":"10.1016\/j.heares.2022.108503_bib0054","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1097\/MAO.0b013e3182487fc8","article-title":"Feedback analysis in percutaneous bone-conduction device and bone-conduction implant on a dry cranium","volume":"33","author":"Taghavi","year":"2012","journal-title":"Otol. Neurotol."},{"issue":"10","key":"10.1016\/j.heares.2022.108503_bib0055","doi-asserted-by":"crossref","first-page":"736","DOI":"10.3109\/14992027.2015.1051665","article-title":"Technical design of a new bone conduction implant (BCI) system","volume":"54","author":"Taghavi","year":"2015","journal-title":"Int. J. Audiol."},{"issue":"1","key":"10.1016\/j.heares.2022.108503_bib0056","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1097\/MAO.0b013e3181c29fec","article-title":"Bone-anchored hearing aid: a comparison of surgical techniques","volume":"31","author":"van de Berg","year":"2010","journal-title":"Otol. Neurotol."}],"container-title":["Hearing Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0378595522000727?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0378595522000727?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T10:59:38Z","timestamp":1759921178000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0378595522000727"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8]]},"references-count":57,"alternative-id":["S0378595522000727"],"URL":"https:\/\/doi.org\/10.1016\/j.heares.2022.108503","relation":{},"ISSN":["0378-5955"],"issn-type":[{"value":"0378-5955","type":"print"}],"subject":[],"published":{"date-parts":[[2022,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Long-term follow-up and review of the Bone Conduction Implant","name":"articletitle","label":"Article Title"},{"value":"Hearing Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heares.2022.108503","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"108503"}}