{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T11:06:56Z","timestamp":1794654416600,"version":"4.9.1"},"reference-count":67,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,1,18]],"date-time":"2024-01-18T00:00:00Z","timestamp":1705536000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100021851","name":"William Demant Fonden","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100021851","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Hearing Research"],"published-print":{"date-parts":[[2024,3]]},"DOI":"10.1016\/j.heares.2024.108953","type":"journal-article","created":{"date-parts":[[2024,1,21]],"date-time":"2024-01-21T01:17:02Z","timestamp":1705799822000},"page":"108953","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"special_numbering":"C","title":["Tripolar configuration and pulse shape in cochlear implants reduce channel interactions in the temporal domain"],"prefix":"10.1016","volume":"443","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6408-9206","authenticated-orcid":false,"given":"Gunnar L","family":"Quass","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrej","family":"Kral","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.heares.2024.108953_bib0001","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1177\/1084713810375249","article-title":"Probing the electrode-neuron interface with focused cochlear implant stimulation","volume":"14","author":"Arenberg Bierer","year":"2010","journal-title":"Trends Amplif."},{"issue":"6","key":"10.1016\/j.heares.2024.108953_bib0002","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1097\/AUD.0000000000000566","article-title":"A dynamically focusing cochlear implant strategy can improve vowel identification in noise","volume":"39","author":"Arenberg","year":"2018","journal-title":"Ear Hear."},{"key":"10.1016\/j.heares.2024.108953_bib0003","doi-asserted-by":"crossref","first-page":"3245","DOI":"10.1002\/cne.23594","article-title":"Variations in microanatomy of the human cochlea","volume":"522","author":"Avci","year":"2014","journal-title":"J. Comp. Neurol."},{"issue":"5","key":"10.1016\/j.heares.2024.108953_bib0004","doi-asserted-by":"crossref","first-page":"2908","DOI":"10.1121\/1.2354017","article-title":"Speech recognition in normal hearing and sensorineural hearing loss as a function of the number of spectral channels","volume":"120","author":"Ba\u015fkent","year":"2006","journal-title":"J. Acoust. Soc. Am."},{"key":"10.1016\/j.heares.2024.108953_bib0005","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1177\/00034894991080S414","article-title":"Simultaneous analog stimulation (SAS)\u2013continuous interleaved sampler (CIS) pilot comparison study in Europe","volume":"177","author":"Battmer","year":"1999","journal-title":"Ann. Otol. Rhinol. Laryngol. Suppl."},{"key":"10.1016\/j.heares.2024.108953_bib64","doi-asserted-by":"crossref","first-page":"293","DOI":"10.18637\/jss.v031.i10","article-title":"CircStat\u202f: A MATLAB Toolbox for Circular Statistics","volume":"31","author":"Berens","year":"2009","journal-title":"J. Stat. Softw."},{"issue":"2","key":"10.1016\/j.heares.2024.108953_bib0006","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1097\/AUD.0b013e3181645336","article-title":"Current steering and current focusing in cochlear implants: comparison of monopo2lar, tripolar, and virtual channel electrode configurations","volume":"29","author":"Berenstein","year":"2008","journal-title":"Ear Hear."},{"issue":"1","key":"10.1016\/j.heares.2024.108953_bib0007","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1121\/10.0012163","article-title":"Speech recognition as a function of the number of channels for Mid-Scala electrode array recipients","volume":"152","author":"Berg","year":"2022","journal-title":"J. Acoust. Soc. Am."},{"key":"10.1016\/j.heares.2024.108953_bib0008","doi-asserted-by":"crossref","unstructured":"Bernhard, N., Gauger, U., Romo, E., Uecker, F.C., Olze, H., Knopke, S., H\u00e4nsel, T., 2021. Duration of deafness impacts auditory performance after cochlear implantation\u00a0: a meta-analysis 291\u2013301. 10.1002\/lio2.528.","DOI":"10.1002\/lio2.528"},{"issue":"3","key":"10.1016\/j.heares.2024.108953_bib0009","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.1121\/1.2436712","article-title":"Threshold and channel interaction in cochlear implant users: evaluation of the tripolar electrode configuration","volume":"121","author":"Bierer","year":"2007","journal-title":"J. Acoust. Soc. Am."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0010","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.heares.2010.08.006","article-title":"Partial tripolar cochlear implant stimulation: spread of excitation and forward masking in the inferior colliculus","volume":"270","author":"Bierer","year":"2010","journal-title":"Hear. Res."},{"issue":"1","key":"10.1016\/j.heares.2024.108953_bib0011","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1007\/s10162-003-3057-7","article-title":"Cortical responses to cochlear implant stimulation: channel interactions","volume":"5","author":"Bierer","year":"2004","journal-title":"J. Assoc. Res. Otolaryngol."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0012","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.heares.2008.03.006","article-title":"Current focusing and steering: modeling, physiology, and psychophysics","volume":"242","author":"Bonham","year":"2008","journal-title":"Hear. Res."},{"issue":"5 Pt 1","key":"10.1016\/j.heares.2024.108953_bib0013","doi-asserted-by":"crossref","first-page":"2658","DOI":"10.1121\/1.409835","article-title":"Pitch perception for different modes of stimulation using the cochlear multiple-electrode prosthesis","volume":"95","author":"Busby","year":"1994","journal-title":"J. Acoust. Soc. Am."},{"issue":"3","key":"10.1016\/j.heares.2024.108953_bib0014","doi-asserted-by":"crossref","first-page":"1637","DOI":"10.1121\/1.428448","article-title":"Effects of phase duration and electrode separation on loudness growth in cochlear implant listeners","volume":"107","author":"Chatterjee","year":"2000","journal-title":"J. Acoust. Soc. Am."},{"issue":"9","key":"10.1016\/j.heares.2024.108953_bib0015","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1080\/14992027.2019.1601270","article-title":"Dynamic current focusing for loudness encoding in cochlear implants: a take-home trial","volume":"58","author":"De Jong","year":"2019","journal-title":"Int. J. Audiol."},{"issue":"1","key":"10.1016\/j.heares.2024.108953_bib0016","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1097\/AUD.0000000000000593","article-title":"Dynamic current focusing: a novel approach to loudness coding in cochlear implants","volume":"40","author":"De Jong","year":"2019","journal-title":"Ear Hear."},{"issue":"5","key":"10.1016\/j.heares.2024.108953_bib0017","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1044\/jslhr.4005.1201","article-title":"Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor","volume":"40","author":"Fishman","year":"1997","journal-title":"J. Speech. Lang. Hear. Res."},{"issue":"2","key":"10.1016\/j.heares.2024.108953_bib0018","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1121\/1.1381538","article-title":"Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants","volume":"110","author":"Friesen","year":"2001","journal-title":"J. Acoust. Soc. Am."},{"issue":"3","key":"10.1016\/j.heares.2024.108953_bib0019","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1080\/14670100.2022.2026025","article-title":"Facial nerve stimulation in cochlear implant users\u2013a matter of stimulus parameters","volume":"23","author":"G\u00e4rtner","year":"2022","journal-title":"Cochlear. Implants Int."},{"issue":"6","key":"10.1016\/j.heares.2024.108953_bib0020","doi-asserted-by":"crossref","DOI":"10.1088\/1741-2560\/12\/6\/066005","article-title":"Electrophysiological channel interactions using focused multipolar stimulation for cochlear implants","volume":"12","author":"George","year":"2015","journal-title":"J. Neural Eng."},{"issue":"3","key":"10.1016\/j.heares.2024.108953_bib0021","doi-asserted-by":"crossref","DOI":"10.1088\/1741-2560\/12\/3\/036003","article-title":"Evaluation of focused multipolar stimulation for cochlear implants in long-term deafened cats","volume":"12","author":"George","year":"2015","journal-title":"J. Neural Eng."},{"key":"10.1016\/j.heares.2024.108953_bib65","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1152\/jn.1969.32.4.613","article-title":"dichotic tonal stimuli: some physiological mechanisms of sound localization","volume":"32","author":"Goldberg","year":"1969","journal-title":"J. Neurophysiol."},{"issue":"1","key":"10.1016\/j.heares.2024.108953_bib0022","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/0378-5955(84)90094-7","article-title":"Discharge patterns of cat primary auditory fibers with electrical stimulation of the cochlea","volume":"13","author":"Hartmann","year":"1984","journal-title":"Hear. Res."},{"issue":"11","key":"10.1016\/j.heares.2024.108953_bib0023","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1177\/000348949009901104","article-title":"Dimensions of the scala tympani in the human and cat with reference to cochlear implants","volume":"99","author":"Hatsushika","year":"1990","journal-title":"Ann. Otol. Rhinol. Laryngol."},{"key":"10.1016\/j.heares.2024.108953_bib0024","article-title":"Polarity sensitivity from electrical stimulation of degenerated human cochlear neurons","volume":"15","author":"Heshmat","year":"2021","journal-title":"Front. Neurosci."},{"issue":"4","key":"10.1016\/j.heares.2024.108953_bib0025","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1007\/s10162-019-00718-2","article-title":"Evaluating psychophysical polarity sensitivity as an indirect estimate of neural status in cochlear implant listeners","volume":"20","author":"Jahn","year":"2019","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"10.1016\/j.heares.2024.108953_bib0026","doi-asserted-by":"crossref","DOI":"10.1016\/j.heares.2021.108413","article-title":"The relation between polarity sensitivity and neural degeneration in a computational model of cochlear implant stimulation","volume":"415","author":"Kalkman","year":"2022","journal-title":"Hear. Res."},{"key":"10.1016\/j.heares.2024.108953_bib0027","doi-asserted-by":"crossref","DOI":"10.1016\/j.heares.2020.108057","article-title":"Late electrically-evoked compound action potentials as markers for acute micro-lesions of spiral ganglion neurons","volume":"413","author":"Konerding","year":"2022","journal-title":"Hear. Res."},{"issue":"1","key":"10.1016\/j.heares.2024.108953_bib0028","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s10162-022-00878-8","article-title":"Anodic polarity minimizes facial nerve stimulation as a side effect of cochlear implantation","volume":"24","author":"Konerding","year":"2023","journal-title":"J. Assoc. Res. Otolaryngol."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0029","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/S0378-5955(98)00061-6","article-title":"Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents","volume":"121","author":"Kral","year":"1998","journal-title":"Hear. Res."},{"key":"10.1016\/j.heares.2024.108953_bib0030","series-title":"The Senses. A Comprehensive Reference","first-page":"923","article-title":"Cochlear implants: neuroprosthetic hearing and the brain","author":"Kral","year":"2021"},{"key":"10.1016\/j.heares.2024.108953_bib0031","series-title":"Prostheses for the Brain: Introduction to Neuroprosthetics","author":"Kral","year":"2021"},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0032","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.heares.2009.04.007","article-title":"Virtual channel discrimination is improved by current focusing in cochlear implant recipients","volume":"254","author":"Landsberger","year":"2009","journal-title":"Hear. Res."},{"issue":"2","key":"10.1016\/j.heares.2024.108953_bib0033","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1121\/1.2749414","article-title":"Loudness growth observed under partially tripolar stimulation: model and data from cochlear implant listeners","volume":"122","author":"Litvak","year":"2007","journal-title":"J. Acoust. Soc. Am."},{"key":"10.1016\/j.heares.2024.108953_bib0034","doi-asserted-by":"crossref","first-page":"1926","DOI":"10.1152\/jn.00497.2005","article-title":"Phase-locked responses to pure tones in the inferior colliculus","volume":"95","author":"Liu","year":"2006","journal-title":"J. Neurophysiol."},{"issue":"2","key":"10.1016\/j.heares.2024.108953_bib0035","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1007\/s00429-007-0146-0","article-title":"A detailed 3D model of the guinea pig cochlea","volume":"212","author":"Liu","year":"2007","journal-title":"Brain Struct. Funct."},{"issue":"3","key":"10.1016\/j.heares.2024.108953_bib0036","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1109\/51.765187","article-title":"Signal-processing techniques for cochlear implants","volume":"18","author":"Loizou","year":"1999","journal-title":"IEEe Eng. Med. Biol. Mag."},{"issue":"2","key":"10.1016\/j.heares.2024.108953_bib0037","doi-asserted-by":"crossref","DOI":"10.1007\/s10162-008-0112-4","article-title":"Higher sensitivity of human auditory nerve fibers to positive electrical currents","volume":"9","author":"Macherey","year":"2008","journal-title":"JARO"},{"key":"10.1016\/j.heares.2024.108953_bib0038","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1007\/978-3-319-25474-6_15","article-title":"Effects of pulse shape and polarity on sensitivity to cochlear implant stimulation: a chronic study in guinea pigs","volume":"894","author":"Macherey","year":"2016","journal-title":"Adv. Exp. Med. Biol."},{"key":"10.1016\/j.heares.2024.108953_bib0039","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1007\/s10162-006-0040-0","article-title":"Asymmetric pulses in cochlear implants: effects of pulse shape, polarity, and rate","volume":"7","author":"Macherey","year":"2006","journal-title":"J. Assoc. Res. Otolaryngol."},{"issue":"5","key":"10.1016\/j.heares.2024.108953_bib0040","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1097\/01.mao.0000185060.74339.9d","article-title":"Speech perception with mono- and quadrupolar electrode configurations: a crossover study","volume":"26","author":"Mens","year":"2005","journal-title":"Otol. Neurotol."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0041","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S0378-5955(99)00012-X","article-title":"Electrically evoked single-fiber action potentials from cat: responses to monopolar, monophasic stimulation","volume":"130","author":"Miller","year":"1999","journal-title":"Hear. Res."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0042","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0378-5955(98)00046-X","article-title":"Electrically evoked compound action potentials of guinea pig and cat: responses to monopolar, monophasic stimulation","volume":"119","author":"Miller","year":"1998","journal-title":"Hear. Res."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0043","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/0378-5955(93)90244-U","article-title":"Effects of phase duration on detection of electrical stimulation of the human cochlea","volume":"67","author":"Moon","year":"1993","journal-title":"Hear. Res."},{"issue":"1-3","key":"10.1016\/j.heares.2024.108953_bib0044","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/0378-5955(90)90101-T","article-title":"Degeneration of cochlear neurons as seen in the spiral ganglion of man","volume":"49","author":"Nadol","year":"1990","journal-title":"Hear. Res."},{"issue":"1","key":"10.1016\/j.heares.2024.108953_bib0045","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41598-020-60181-5","article-title":"Ramped pulse shapes are more efficient for cochlear implant stimulation in an animal model","volume":"10","author":"Navntoft","year":"2020","journal-title":"Sci. Rep."},{"issue":"3","key":"10.1016\/j.heares.2024.108953_bib0046","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/0378-5955(87)90196-1","article-title":"Auditory-nerve single-neuron thresholds to electrical stimulation from scala tympani electrodes","volume":"31","author":"Parkins","year":"1987","journal-title":"Hear. Res."},{"issue":"4 Pt 1","key":"10.1016\/j.heares.2024.108953_bib0047","doi-asserted-by":"crossref","first-page":"1857","DOI":"10.1121\/1.401665","article-title":"Stimulus features affecting psychophysical detection thresholds for electrical stimulation of the cochlea. I: Phase duration and stimulus duration","volume":"90","author":"Pfingst","year":"1991","journal-title":"J. Acoust. Soc. Am."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0048","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/S0378-5955(97)00122-6","article-title":"Effects of stimulus configuration on psychophysical operating levels and on speech recognition with cochlear implants","volume":"112","author":"Pfingst","year":"1997","journal-title":"Hear. Res."},{"key":"10.1016\/j.heares.2024.108953_bib0049","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1162\/089976604774201631","article-title":"Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering","volume":"16","author":"Quiroga","year":"2004","journal-title":"Neural Comput."},{"key":"10.1016\/j.heares.2024.108953_bib0050","doi-asserted-by":"crossref","DOI":"10.1016\/j.heares.2020.108070","article-title":"Level coding by phase duration and asymmetric pulse shape reduce channel interactions in cochlear implants","volume":"396","author":"Quass","year":"2020","journal-title":"Hear. Res."},{"issue":"2","key":"10.1016\/j.heares.2024.108953_bib0051","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1007\/s10162-013-0440-x","article-title":"Auditory-nerve responses to varied inter-phase gap and phase duration of the electric pulse stimulus as predictors for neuronal degeneration","volume":"15","author":"Ramekers","year":"2014","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"10.1016\/j.heares.2024.108953_bib0052","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/0006-8993(75)90364-9","article-title":"Which elements are excited in electrical stimulation of mammalian central nervous system: a review","volume":"98","author":"Ranck","year":"1975","journal-title":"Brain Res."},{"key":"10.1016\/j.heares.2024.108953_bib0053","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1109\/TBME.1986.325670","article-title":"Analysis of models for external stimulation of axons","volume":"33","author":"Rattay","year":"1986","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"1","key":"10.1016\/j.heares.2024.108953_bib0054","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1523\/JNEUROSCI.2968-15.2016","article-title":"Cochlear implant stimulation of a hearing ear generates separate electrophonic and electroneural responses","volume":"36","author":"Sato","year":"2016","journal-title":"J. Neurosci."},{"key":"10.1016\/j.heares.2024.108953_bib0055","doi-asserted-by":"crossref","DOI":"10.1007\/s10162-022-00882-y","article-title":"Cochlear health and cochlear-implant function","author":"Schvartz-Leyzac","year":"2023","journal-title":"J. Assoc. Res. Otolaryngol."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0056","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/S0378-5955(99)00011-8","article-title":"Electrical stimulation of the auditory nerve: II. Effect of stimulus waveshape on single fibre response properties","volume":"130","author":"Shepherd","year":"1999","journal-title":"Hear. Res."},{"key":"10.1016\/j.heares.2024.108953_bib66","doi-asserted-by":"crossref","first-page":"786","DOI":"10.3766\/jaaa.16144","article-title":"Effect of stimulus polarity on physiological spread of excitation in cochlear implants","volume":"28","author":"Spitzer","year":"2017","journal-title":"J. Am. Acad. Audiol."},{"issue":"1","key":"10.1016\/j.heares.2024.108953_bib0057","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1121\/1.1482073","article-title":"The effect of channel interactions on speech recognition in cochlear implant subjects: Predictions from an acoustic model","volume":"112","author":"Throckmorton","year":"2002","journal-title":"J. Acoust. Soc. Am."},{"key":"10.1016\/j.heares.2024.108953_bib67","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s10162-013-0377-0","article-title":"The polarity sensitivity of the electrically stimulated human auditory nerve measured at the level of the brainstem","volume":"14","author":"Undurraga","year":"2013","journal-title":"JARO - J. Assoc. Res. Otolaryngol."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0058","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.heares.2010.06.017","article-title":"Polarity effects on neural responses of the electrically stimulated auditory nerve at different cochlear sites","volume":"269","author":"Undurraga","year":"2010","journal-title":"Hear. Res."},{"issue":"6","key":"10.1016\/j.heares.2024.108953_bib0059","doi-asserted-by":"crossref","first-page":"3703","DOI":"10.1121\/1.2722047","article-title":"Focused intracochlear electric stimulation with phased array channels","volume":"121","author":"van den Honert","year":"2007","journal-title":"J. Acoust. Soc. Am."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0060","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.heares.2004.08.006","article-title":"Effects of waveform shape on human sensitivity to electrical stimulation of the inner ear","volume":"200","author":"Van Wieringen","year":"2005","journal-title":"Hear. Res."},{"issue":"8","key":"10.1016\/j.heares.2024.108953_bib0061","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1001\/archotol.1984.00800340005002","article-title":"Multichannel cochlear implants. Channel interactions and processor design","volume":"110","author":"White","year":"1984","journal-title":"Arch. Otolaryngol."},{"issue":"1-2","key":"10.1016\/j.heares.2024.108953_bib0062","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0378-5955(01)00314-8","article-title":"Dimensions of the vestibular and tympanic scalae of the cochlea in selected mammals","volume":"161","author":"Wysocki","year":"2001","journal-title":"Hear. Res."},{"issue":"1","key":"10.1016\/j.heares.2024.108953_bib0063","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1109\/86.372900","article-title":"Electronic design of a cochlear implant for multichannel high-rate pulsatile stimulation strategies","volume":"3","author":"Zierhofer","year":"1995","journal-title":"IEEE Trans. Rehab. Eng."}],"container-title":["Hearing Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0378595524000066?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0378595524000066?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T11:05:24Z","timestamp":1759921524000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0378595524000066"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3]]},"references-count":67,"alternative-id":["S0378595524000066"],"URL":"https:\/\/doi.org\/10.1016\/j.heares.2024.108953","relation":{},"ISSN":["0378-5955"],"issn-type":[{"value":"0378-5955","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Tripolar configuration and pulse shape in cochlear implants reduce channel interactions in the temporal domain","name":"articletitle","label":"Article Title"},{"value":"Hearing Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heares.2024.108953","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"108953"}}