{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T06:15:43Z","timestamp":1793859343583,"version":"4.6.1"},"reference-count":53,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2019,11,1]],"date-time":"2019-11-01T00:00:00Z","timestamp":1572566400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,11,1]],"date-time":"2019-11-01T00:00:00Z","timestamp":1572566400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,10,18]],"date-time":"2019-10-18T00:00:00Z","timestamp":1571356800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["cell.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heliyon"],"published-print":{"date-parts":[[2019,11]]},"DOI":"10.1016\/j.heliyon.2019.e02704","type":"journal-article","created":{"date-parts":[[2019,11,14]],"date-time":"2019-11-14T08:31:17Z","timestamp":1573720277000},"page":"e02704","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["Radial basis function for fast voltage stability assessment using Phasor Measurement Units"],"prefix":"10.1016","volume":"5","author":[{"given":"Jorge W.","family":"Gonzalez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Idi A.","family":"Isaac","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriel J.","family":"Lopez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hugo A.","family":"Cardona","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriel J.","family":"Salazar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John M.","family":"Rincon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.heliyon.2019.e02704_bib1","doi-asserted-by":"crossref","first-page":"1922","DOI":"10.1109\/TPWRS.2005.857942","article-title":"Causes of the 2003 major grid blackouts in North America and Europe, and recommended means to improve system dynamic performance","volume":"20","author":"Andersson","year":"2005","journal-title":"IEEE Trans. Power Syst."},{"key":"10.1016\/j.heliyon.2019.e02704_bib2","series-title":"IEEE\/PES General Meeting, Denver","article-title":"General blackout in Italy sunday September 28, 2003, h.03:28:00","author":"Corsi","year":"2004"},{"key":"10.1016\/j.heliyon.2019.e02704_bib3","series-title":"Proc. 27th IEEE Conference on Decision and Control, Austin","article-title":"The power system failure on July 23, 1987 in Tokyo","author":"Kurita","year":"1988"},{"key":"10.1016\/j.heliyon.2019.e02704_bib4","series-title":"International Conference Industrial and Information Systems (IICIIS), Sri Lanka","article-title":"Power system blackouts - literature review","author":"Atputharajah","year":"2009"},{"issue":"2","key":"10.1016\/j.heliyon.2019.e02704_bib5","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1109\/TPWRD.2013.2247426","article-title":"Online voltage security assessment based on wide-area measurements","volume":"28","author":"Beiraghi","year":"2013","journal-title":"IEEE Trans. Power Deliv."},{"issue":"4","key":"10.1016\/j.heliyon.2019.e02704_bib6","doi-asserted-by":"crossref","first-page":"2557","DOI":"10.1109\/TPWRS.2015.2487996","article-title":"SVD-based voltage stability assessment from phasor measurement unit data","volume":"31","author":"Lim","year":"2016","journal-title":"IEEE Trans. Power Syst."},{"issue":"3","key":"10.1016\/j.heliyon.2019.e02704_bib7","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1109\/TPWRS.2008.922586","article-title":"A\u00a0real-time voltage instability identification algorithm based on local phasor measurements","volume":"23","author":"Corsi","year":"2008","journal-title":"IEEE Trans. Power Syst."},{"issue":"3","key":"10.1016\/j.heliyon.2019.e02704_bib8","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1109\/TPWRS.2006.876702","article-title":"Local voltage-stability index using tellegen's Theorem","volume":"21","author":"Smon","year":"2006","journal-title":"IEEE Trans. Power Syst."},{"issue":"4","key":"10.1016\/j.heliyon.2019.e02704_bib9","doi-asserted-by":"crossref","first-page":"1955","DOI":"10.1109\/TPWRS.2007.907380","article-title":"Power system loading margin estimation using a neuro-fuzzy approach","volume":"22","author":"Torres","year":"2007","journal-title":"IEEE Trans. Power Syst."},{"issue":"4","key":"10.1016\/j.heliyon.2019.e02704_bib10","doi-asserted-by":"crossref","first-page":"4448","DOI":"10.1109\/TPWRS.2013.2268013","article-title":"A\u00a0new and fast method for preventive control selection in voltage stability analysis","volume":"28","author":"Mansour","year":"2013","journal-title":"IEEE Trans. Power Syst."},{"issue":"1","key":"10.1016\/j.heliyon.2019.e02704_bib11","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1109\/TPWRS.2009.2036460","article-title":"A\u00a0fast local index for online estimation of closeness to loadability limit","volume":"25","author":"Parniani","year":"2010","journal-title":"IEEE Trans. Power Syst."},{"issue":"1","key":"10.1016\/j.heliyon.2019.e02704_bib12","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1109\/TPWRS.2005.860945","article-title":"Fast computation of voltage stability security margins using nonlinear programming techniques","volume":"21","author":"Zarate","year":"2006","journal-title":"IEEE Trans. Power Syst."},{"issue":"2","key":"10.1016\/j.heliyon.2019.e02704_bib13","doi-asserted-by":"crossref","first-page":"1517","DOI":"10.1109\/TPWRS.2015.2422072","article-title":"Preventive control design for voltage stability considering multiple critical contingencies","volume":"31","author":"Mansour","year":"2016","journal-title":"IEEE Trans. Power Syst."},{"issue":"4","key":"10.1016\/j.heliyon.2019.e02704_bib14","doi-asserted-by":"crossref","first-page":"4857","DOI":"10.1109\/TPWRS.2013.2273501","article-title":"Incorporating generator equivalent model into voltage stability analysis","volume":"28","author":"Wang","year":"2013","journal-title":"IEEE Trans. Power Syst."},{"issue":"1","key":"10.1016\/j.heliyon.2019.e02704_bib15","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1109\/TPWRS.2015.2402436","article-title":"Voltage stability assessment using equivalent nodal analysis","volume":"31","author":"Lee","year":"2016","journal-title":"IEEE Trans. Power Syst."},{"issue":"4","key":"10.1016\/j.heliyon.2019.e02704_bib16","doi-asserted-by":"crossref","first-page":"2271","DOI":"10.1109\/TPWRS.2012.2191310","article-title":"Distributed online monitoring of quasi-static voltage collapse in multi-area power systems","volume":"27","author":"Xie","year":"2012","journal-title":"IEEE Trans. Power Syst."},{"issue":"5","key":"10.1016\/j.heliyon.2019.e02704_bib17","doi-asserted-by":"crossref","first-page":"2591","DOI":"10.1109\/TPWRS.2014.2369502","article-title":"Coordinated decentralized emergency voltage and reactive power control to prevent long-term voltage instability in a power system","volume":"30","author":"Islam","year":"2015","journal-title":"IEEE Trans. Power Syst."},{"issue":"2","key":"10.1016\/j.heliyon.2019.e02704_bib18","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1109\/TSG.2015.2410219","article-title":"Distributed voltage security monitoring in large power systems using synchrophasors","volume":"7","author":"Liu","year":"2016","journal-title":"IEEE Trans. Smart Grid"},{"issue":"2","key":"10.1016\/j.heliyon.2019.e02704_bib19","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1109\/TSG.2015.2467215","article-title":"Wide-area voltage monitoring and optimization","volume":"7","author":"Li","year":"2016","journal-title":"IEEE Trans. Smart Grid"},{"key":"10.1016\/j.heliyon.2019.e02704_bib20","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.ijepes.2014.01.019","article-title":"Power system voltage stability monitoring using artificial neural networks with a reduced set of inputs","volume":"58","author":"Bahmanyar","year":"2014","journal-title":"Int. J. Electr. Power Energy Syst."},{"issue":"2","key":"10.1016\/j.heliyon.2019.e02704_bib21","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1109\/TPWRS.2004.826765","article-title":"New method for generators' angles and angular velocities prediction for transient stability assessment of multimachine power systems using recurrent artificial neural network","volume":"19","author":"Bahbah","year":"2004","journal-title":"IEEE Trans. Power Syst."},{"issue":"3","key":"10.1016\/j.heliyon.2019.e02704_bib22","doi-asserted-by":"crossref","first-page":"40","DOI":"10.17159\/2413-3051\/2012\/v23i3a3171","article-title":"Comparing performance of MLP and RBF neural network models for predicting South Africa\u2019s energy consumption","volume":"23","author":"Oludolapo","year":"2012","journal-title":"J.\u00a0Energy South. Afr."},{"key":"10.1016\/j.heliyon.2019.e02704_bib23","series-title":"Proc. IEEE Power Engineering Society Winter Meeting Conference, New York","article-title":"Comparison of MLP and RBF neural networks using deviation signals for on-line identification of a synchronous generator","author":"Park","year":"2002"},{"issue":"1","key":"10.1016\/j.heliyon.2019.e02704_bib24","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.ijepes.2007.10.004","article-title":"Radial basis function neural network for power system load flow","volume":"30","author":"Karami","year":"2008","journal-title":"Int. J. Electr. Power Energy Syst."},{"key":"10.1016\/j.heliyon.2019.e02704_bib25","series-title":"IEEE PES Power Africa 2007 Conference and Exposition, Johannesburg","article-title":"Online voltage stability monitoring and contingency ranking using RBF neural network","author":"Moradzadeh","year":"2007"},{"issue":"9","key":"10.1016\/j.heliyon.2019.e02704_bib26","doi-asserted-by":"crossref","first-page":"1550","DOI":"10.1016\/j.ijepes.2011.06.008","article-title":"On-line voltage stability assessment using radial basis function network model with reduced input features","volume":"33","author":"Devaraj","year":"2011","journal-title":"Int. J. Electr. Power Energy Syst."},{"key":"10.1016\/j.heliyon.2019.e02704_bib27","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.ijepes.2013.03.007","article-title":"Current state of neural networks applications in power system monitoring and control","volume":"51","author":"Lokman","year":"2013","journal-title":"Int. J. Electr. Power Energy Syst."},{"issue":"4","key":"10.1016\/j.heliyon.2019.e02704_bib28","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.1109\/TPWRS.2003.818607","article-title":"Fast voltage contingency screening using radial basis function neural network","volume":"18","author":"Jain","year":"2003","journal-title":"IEEE Trans. Power Syst."},{"issue":"1","key":"10.1016\/j.heliyon.2019.e02704_bib29","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ijepes.2007.06.004","article-title":"Multicontingency voltage stability monitoring of a power system using an adaptive radial basis function network","volume":"30","author":"Chakrabarti","year":"2008","journal-title":"Int. J. Electr. Power Energy Syst."},{"issue":"3","key":"10.1016\/j.heliyon.2019.e02704_bib30","doi-asserted-by":"crossref","first-page":"2749","DOI":"10.1109\/JSYST.2016.2645165","article-title":"Nonlinear load sharing and voltage compensation of microgrids based on harmonic power-flow calculations using radial basis function neural networks","volume":"12","author":"Baghaee","year":"2018","journal-title":"IEEE Syst. J."},{"key":"10.1016\/j.heliyon.2019.e02704_bib31","series-title":"Synchronized Phasor Measurements and Their Applications","author":"Phadke","year":"2008"},{"issue":"5","key":"10.1016\/j.heliyon.2019.e02704_bib32","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1109\/JPROC.2005.846336","article-title":"Design aspects for wide-area monitoring and control systems","volume":"93","author":"Zima","year":"2005","journal-title":"Proc. IEEE"},{"issue":"4","key":"10.1016\/j.heliyon.2019.e02704_bib33","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1049\/ip-gtd:19981977","article-title":"Monitoring and assessment of voltage stability margins using artificial neural networks with a reduced input set","volume":"145","author":"Popovic","year":"1998","journal-title":"IEE Proc. Gener. Transm. Distrib."},{"issue":"3","key":"10.1016\/j.heliyon.2019.e02704_bib34","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1109\/TPWRS.2009.2038059","article-title":"Online monitoring of voltage stability margin using an artificial neural network","volume":"25","author":"Zhou","year":"2010","journal-title":"IEEE Trans. Power Syst."},{"key":"10.1016\/j.heliyon.2019.e02704_bib35","series-title":"Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies, Nanjing, 2008","article-title":"PMU based voltage stability analysis for transmission corridors","author":"Liu","year":"2008"},{"key":"10.1016\/j.heliyon.2019.e02704_bib36","series-title":"Eighth International Multi-Conference on Systems, Signals & Devices","article-title":"Determination of static voltage stability-margin of the power system prior to voltage collapse","author":"Jalboub","year":"2011"},{"key":"10.1016\/j.heliyon.2019.e02704_bib37","series-title":"IEEE\/PES General Meeting, Denver","article-title":"Monitoring voltage collapse margin with synchrophasors across transmission corridors with multiple lines and multiple contingencies","author":"Ramirez","year":"2015"},{"key":"10.1016\/j.heliyon.2019.e02704_bib38","series-title":"Transmission & Distribution Conference & Exposition: Asia and Pacific, Seoul, 2009","article-title":"Development of voltage stability index using synchro-phasor based data","author":"Han","year":"2009"},{"key":"10.1016\/j.heliyon.2019.e02704_bib39","series-title":"IEEE PES T&D 2010, New Orleans","article-title":"Voltage stability monitoring using PMU data in KEPCO system","author":"Han","year":"2010"},{"key":"10.1016\/j.heliyon.2019.e02704_bib40","series-title":"2nd International Conference on Power, Control and Embedded Systems, Allahabad, 2012","article-title":"Voltage stability assessment using Phasor Measurement Units in power network with full system observability","author":"Kesherwani","year":"2012"},{"issue":"3","key":"10.1016\/j.heliyon.2019.e02704_bib41","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1109\/TPWRS.2008.926723","article-title":"Optimal placement of PMUs by integer linear programming","volume":"23","author":"Gou","year":"2008","journal-title":"IEEE Trans. Power Syst."},{"issue":"3","key":"10.1016\/j.heliyon.2019.e02704_bib42","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1109\/TPWRS.2008.926475","article-title":"Generalized integer linear programming formulation for optimal PMU placement","volume":"23","author":"Gou","year":"2008","journal-title":"IEEE Trans. Power Syst."},{"key":"10.1016\/j.heliyon.2019.e02704_bib43","series-title":"Documentation Center, Matlab","author":"MathWorks","year":"2017"},{"issue":"2","key":"10.1016\/j.heliyon.2019.e02704_bib44","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1109\/5.823999","article-title":"Voltage instability: phenomena, countermeasures, and analysis methods","volume":"88","author":"Cutsem","year":"2000","journal-title":"Proc. IEEE"},{"key":"10.1016\/j.heliyon.2019.e02704_bib45","series-title":"IEEE Power and Energy Society General Meeting, San Diego, 2011","article-title":"A\u00a0short survey of methods for voltage instability detection","author":"Glavic","year":"2011"},{"key":"10.1016\/j.heliyon.2019.e02704_bib46","series-title":"IEEE Power Engineering Society General Meeting, 2004, Denver","article-title":"Real-time estimation of security from voltage collapse using synchronized phasor measurements","author":"Khatib","year":"2004"},{"issue":"3","key":"10.1016\/j.heliyon.2019.e02704_bib47","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1109\/TPWRS.2005.851911","article-title":"An open source power system Analysis Toolbox","volume":"20","author":"Milano","year":"2005","journal-title":"IEEE Trans. Power Syst."},{"key":"10.1016\/j.heliyon.2019.e02704_bib48","series-title":"Power System Stability and Control","author":"Kundur","year":"1994"},{"key":"10.1016\/j.heliyon.2019.e02704_bib49","series-title":"Voltage Stability of Electric Power Systems","author":"Cutsem","year":"1998"},{"issue":"2","key":"10.1016\/j.heliyon.2019.e02704_bib50","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1109\/72.80341","article-title":"Orthogonal least squares learning algorithm for radial basis function networks","volume":"2","author":"Chen","year":"1991","journal-title":"IEEE Trans. Neural Netw."},{"key":"10.1016\/j.heliyon.2019.e02704_bib51","series-title":"Documentation Center, Neural Network Toolbox","author":"MathWorks","year":"2017"},{"key":"10.1016\/j.heliyon.2019.e02704_bib52","series-title":"Power Factory User Manual Version 15.2","author":"DIgSILENT","year":"2016"},{"key":"10.1016\/j.heliyon.2019.e02704_bib53","series-title":"DSA Tools-VSAT-Voltage Security Assessment Tool User Manual","author":"P. Labs","year":"2013"}],"container-title":["Heliyon"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844019363649?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844019363649?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,2,2]],"date-time":"2025-02-02T08:57:06Z","timestamp":1738486626000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405844019363649"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11]]},"references-count":53,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2019,11]]}},"alternative-id":["S2405844019363649"],"URL":"https:\/\/doi.org\/10.1016\/j.heliyon.2019.e02704","relation":{},"ISSN":["2405-8440"],"issn-type":[{"value":"2405-8440","type":"print"}],"subject":[],"published":{"date-parts":[[2019,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Radial basis function for fast voltage stability assessment using Phasor Measurement Units","name":"articletitle","label":"Article Title"},{"value":"Heliyon","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heliyon.2019.e02704","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"e02704"}}