{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T09:07:33Z","timestamp":1790759253234,"version":"4.1.0"},"reference-count":67,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,10,4]],"date-time":"2023-10-04T00:00:00Z","timestamp":1696377600000},"content-version":"vor","delay-in-days":3,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["cell.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heliyon"],"published-print":{"date-parts":[[2023,10]]},"DOI":"10.1016\/j.heliyon.2023.e20700","type":"journal-article","created":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T12:54:57Z","timestamp":1697115297000},"page":"e20700","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"title":["The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair"],"prefix":"10.1016","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8372-0550","authenticated-orcid":false,"given":"Wojciech","family":"Kazimierczak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ewa","family":"Nowak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natalia","family":"Kazimierczak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomasz","family":"Jankowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Agnieszka","family":"Jankowska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4307-6852","authenticated-orcid":false,"given":"Zbigniew","family":"Serafin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.heliyon.2023.e20700_bib1","doi-asserted-by":"crossref","DOI":"10.1046\/j.0007-1323.2001.02014.x","article-title":"Randomized clinical trial of screening for abdominal aortic aneurysm in women","volume":"89","author":"Scott","year":"2002","journal-title":"Br. J. Surg."},{"key":"10.1016\/j.heliyon.2023.e20700_bib2","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2007.01.043","article-title":"The impact of gender on presentation, therapy, and mortality of abdominal aortic aneurysm in the United States, 2001-2004","volume":"45","author":"McPhee","year":"2007","journal-title":"J. Vasc. Surg."},{"key":"10.1016\/j.heliyon.2023.e20700_bib3","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejvs.2018.09.020","article-title":"Editor's choice \u2013 European society for vascular surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms","volume":"57","author":"Wanhainen","year":"2019","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"10.1016\/j.heliyon.2023.e20700_bib4","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2017.10.044","article-title":"The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm","volume":"67","author":"Chaikof","year":"2018","journal-title":"J. Vasc. Surg."},{"key":"10.1016\/j.heliyon.2023.e20700_bib5","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2013.08.005","article-title":"Visceral stent patency in fenestrated stent grafting for abdominal aortic aneurysm repair","volume":"59","author":"Grimme","year":"2014","journal-title":"J. Vasc. Surg."},{"key":"10.1016\/j.heliyon.2023.e20700_bib6","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvs.2014.10.025","article-title":"Fenestrated endovascular repair of abdominal aortic aneurysms is associated with increased morbidity but comparable mortality with infrarenal endovascular aneurysm repair","author":"Glebova","year":"2015","journal-title":"J. Vasc. Surg."},{"key":"10.1016\/j.heliyon.2023.e20700_bib7","doi-asserted-by":"crossref","DOI":"10.1583\/10-3274.1","article-title":"Secondary procedures after aortic aneurysm repair with fenestrated and branched endografts","volume":"18","author":"Troisi","year":"2011","journal-title":"J. Endovasc. Ther."},{"key":"10.1016\/j.heliyon.2023.e20700_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/S0720-048X(02)00364-9","article-title":"Multiple detector-row CT angiography of the renal and mesenteric vessels","author":"Fleischmann","year":"2003","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib9","article-title":"Contemporary imaging methods for the follow-up after endovascular abdominal aneurysm repair: a review","volume":"14","author":"Kazimierczak","year":"2019","journal-title":"Wideochirurgia Inne Tech. Malo Inwazyjne"},{"key":"10.1016\/j.heliyon.2023.e20700_bib10","doi-asserted-by":"crossref","DOI":"10.2214\/AJR.12.9114","article-title":"Dual-energy CT: vascular applications","volume":"199","author":"Vlahos","year":"2012","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib11","doi-asserted-by":"crossref","DOI":"10.5114\/pjr.2018.80348","article-title":"Contemporary follow-up imaging after endovascular repair of lower extremity atherosclerotic lesions","volume":"83","author":"Michalska","year":"2018","journal-title":"Pol. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib12","volume":"vol. 72","author":"Abdellatif","year":"2021"},{"key":"10.1016\/j.heliyon.2023.e20700_bib13","doi-asserted-by":"crossref","DOI":"10.1007\/s00330-020-07633-8","article-title":"Dual-energy CT performance in acute pulmonary embolism: a meta-analysis","volume":"31","author":"Monti","year":"2021","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib14","doi-asserted-by":"crossref","DOI":"10.1007\/s00330-010-1897-1","article-title":"Myocardial perfusion imaging using adenosine-induced stress dual-energy computed tomography of the heart: comparison with cardiac magnetic resonance imaging and conventional coronary angiography","volume":"21","author":"Ko","year":"2011","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib15","doi-asserted-by":"crossref","DOI":"10.1097\/RLI.0b013e31829d91a8","article-title":"Diagnostic accuracy of late iodine-enhancement dual-energy computed tomography for the detection of chronic myocardial infarction compared with late gadolinium-enhancement 3-T magnetic resonance imaging","volume":"48","author":"Wichmann","year":"2013","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib16","article-title":"Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications","volume":"92","author":"D'Angelo","year":"2019","journal-title":"Br. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib17","doi-asserted-by":"crossref","DOI":"10.1016\/j.jvir.2017.06.011","article-title":"Noise-Optimized virtual monoenergetic dual-energy CT improves diagnostic accuracy for the detection of active arterial bleeding of the abdomen","volume":"28","author":"Martin","year":"2017","journal-title":"J. Vasc. Intervent. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib18","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCULATIONAHA.115.014672","article-title":"Contrast-induced nephropathy","volume":"132","author":"Wichmann","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.heliyon.2023.e20700_bib19","article-title":"Dual-energy computed tomography: dose reduction, series reduction, and contrast load reduction in dual-energy computed tomography","volume":"56","author":"Parakh","year":"2018","journal-title":"Radiol. Clin."},{"key":"10.1016\/j.heliyon.2023.e20700_bib20","doi-asserted-by":"crossref","DOI":"10.2214\/AJR.12.9210","article-title":"Dual-energy CT: radiation dose aspects","volume":"199","author":"Henzler","year":"2012","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib21","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2017.12.024","article-title":"Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: effects on image quality, artefacts and diagnostic performance for the detection of stenosis","volume":"99","author":"Leithner","year":"2018","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib22","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2017.12.007","article-title":"Utilization of virtual mono-energetic images (MonoE) derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans","volume":"99","author":"Hickethier","year":"2018","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib23","doi-asserted-by":"crossref","DOI":"10.2214\/AJR.15.15814","article-title":"Prospective comparison of reduced-iodine-dose virtual monochromatic imaging dataset from dual-energy CT angiography with standard-iodine-dose single-energy CT angiography for abdominal aortic aneurysm","volume":"207","author":"Agrawal","year":"2016","journal-title":"Am. J. Roentgenol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib24","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2017.06.017","article-title":"Endoleaks after endovascular aortic aneurysm repair: improved detection with noise-optimized virtual monoenergetic dual-energy CT","volume":"94","author":"Martin","year":"2017","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib25","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2013.11.005","article-title":"Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography","volume":"83","author":"Apfaltrer","year":"2014","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib26","doi-asserted-by":"crossref","DOI":"10.1148\/radiol.2015140857","article-title":"Maximizing iodine contrast-to-noise ratios in abdominal CT imaging through use of energy domain noise reduction and virtual monoenergetic dual-energy CT","volume":"276","author":"Leng","year":"2015","journal-title":"Radiology"},{"key":"10.1016\/j.heliyon.2023.e20700_bib27","article-title":"Spectral CT imaging of prosthetic valve embolization after transcatheter aortic valve implantation","volume":"13","author":"D'Angelo","year":"2023","journal-title":"Diagnostics"},{"key":"10.1016\/j.heliyon.2023.e20700_bib28","doi-asserted-by":"crossref","DOI":"10.1016\/j.acra.2023.03.018","article-title":"Improved detection of endoleaks in virtual monoenergetic images in dual-energy CT angiography following EVAR","author":"Kazimierczak","year":"2023","journal-title":"Acad. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib29","doi-asserted-by":"crossref","DOI":"10.1148\/rg.304095175","article-title":"Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging?","volume":"30","author":"Coursey","year":"2010","journal-title":"Radiographics"},{"key":"10.1016\/j.heliyon.2023.e20700_bib30","doi-asserted-by":"crossref","DOI":"10.1007\/s40134-017-0237-5","article-title":"Cardiac dual-energy CT applications and clinical impact","volume":"5","author":"Albrecht","year":"2017","journal-title":"Curr Radiol Rep"},{"key":"10.1016\/j.heliyon.2023.e20700_bib31","doi-asserted-by":"crossref","DOI":"10.1007\/s00330-015-3997-4","article-title":"Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study","volume":"26","author":"Mangold","year":"2016","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib32","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcct.2016.12.005","article-title":"Monoenergetic reconstructions for imaging of coronary artery stents using spectral detector CT: in-vitro experience and comparison to conventional images","volume":"11","author":"Hickethier","year":"2017","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"10.1016\/j.heliyon.2023.e20700_bib33","doi-asserted-by":"crossref","DOI":"10.2214\/AJR.12.9207","article-title":"Dual-energy CT: oncologic applications","volume":"199","author":"De Cecco","year":"2012","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib34","doi-asserted-by":"crossref","DOI":"10.1097\/RLI.0000000000000387","article-title":"Virtual monoenergetic imaging and iodine perfusion maps improve diagnostic accuracy of dual-energy computed tomography pulmonary angiography with suboptimal contrast attenuation","volume":"52","author":"Leithner","year":"2017","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib35","doi-asserted-by":"crossref","DOI":"10.1148\/radiol.10092212","article-title":"Abdominal CT: Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques","volume":"257","author":"Singh","year":"2010","journal-title":"Radiology"},{"key":"10.1016\/j.heliyon.2023.e20700_bib36","article-title":"Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography","volume":"195","author":"Leipsic","year":"2010","journal-title":"Am. J. Roentgenol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib37","doi-asserted-by":"crossref","DOI":"10.1007\/s00330-013-3027-3","article-title":"Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose","volume":"24","author":"Chen","year":"2014","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib38","doi-asserted-by":"crossref","DOI":"10.1177\/0284185118756952","article-title":"Tailored CT angiography in follow-up after endovascular aneurysm repair (EVAR): combined dose reduction techniques","volume":"59","author":"B\u00f6ning","year":"2018","journal-title":"Acta Radiol"},{"key":"10.1016\/j.heliyon.2023.e20700_bib39","article-title":"Reasons and treatment options for late type II endoleaks","volume":"42","author":"C","year":"2019","journal-title":"Cardiovasc. Intervent. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib40","doi-asserted-by":"crossref","DOI":"10.1097\/01.RVI.0000175900.61777.9A","article-title":"Recurrent endoleak detection and measurement of aneurysm size with CTA after coil embolization of endoleaks","volume":"16","author":"Stavropoulos","year":"2005","journal-title":"J. Vasc. Intervent. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib41","doi-asserted-by":"crossref","DOI":"10.1007\/s00270-017-1812-0","article-title":"Evaluation of CT angiography image quality acquired with single-energy metal artifact reduction (SEMAR) algorithm in patients after complex endovascular aortic repair","volume":"41","author":"Ragusi","year":"2018","journal-title":"Cardiovasc. Intervent. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib42","doi-asserted-by":"crossref","DOI":"10.1007\/s00261-016-0973-7","article-title":"Dual energy CT angiography: pros and cons of dual-energy metal artifact reduction algorithm in patients after endovascular aortic repair","volume":"42","author":"Boos","year":"2017","journal-title":"Abdominal Radiology"},{"key":"10.1016\/j.heliyon.2023.e20700_bib43","doi-asserted-by":"crossref","DOI":"10.1016\/j.diii.2016.07.002","article-title":"CT of hip prosthesis: new techniques and new paradigms","volume":"97","author":"Blum","year":"2016","journal-title":"Diagn Interv Imaging"},{"key":"10.1016\/j.heliyon.2023.e20700_bib44","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0143584","article-title":"Comparison and combination of dual-energy- and iterative-based metal artefact reduction on hip prosthesis and dental implants","volume":"10","author":"Bongers","year":"2015","journal-title":"PLoS One"},{"key":"10.1016\/j.heliyon.2023.e20700_bib45","article-title":"Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography","volume":"28","author":"D'Angelo","year":"2018","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib46","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2020.109166","article-title":"Carotid and cerebrovascular dual-energy computed tomography angiography: optimization of window settings for virtual monoenergetic imaging reconstruction","volume":"130","author":"D'Angelo","year":"2020","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib47","doi-asserted-by":"crossref","DOI":"10.1097\/RLI.0000000000000060","article-title":"Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media","volume":"49","author":"Grant","year":"2014","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib48","doi-asserted-by":"crossref","DOI":"10.1097\/RLI.0000000000000171","article-title":"Advanced virtual monoenergetic computed tomography of hyperattenuating and hypoattenuating liver lesions: ex-vivo and patient experience in various body sizes","volume":"50","author":"Husarik","year":"2015","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib49","doi-asserted-by":"crossref","DOI":"10.1097\/RLI.0000000000000272","article-title":"Comprehensive comparison of virtual monoenergetic and linearly blended reconstruction techniques in third-generation dual-source dual-energy computed tomography angiography of the thorax and abdomen","volume":"51","author":"Albrecht","year":"2016","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib50","doi-asserted-by":"crossref","DOI":"10.1016\/j.acra.2017.12.012","article-title":"Image quality on dual-energy CTPA virtual monoenergetic images: quantitative and qualitative assessment","volume":"25","author":"Dane","year":"2018","journal-title":"Acad. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib51","doi-asserted-by":"crossref","DOI":"10.1007\/s00234-017-1871-6","article-title":"Impact of metal artifact reduction software on image quality of gemstone spectral imaging dual-energy cerebral CT angiography after intracranial aneurysm clipping","volume":"59","author":"Dunet","year":"2017","journal-title":"Neuroradiology"},{"key":"10.1016\/j.heliyon.2023.e20700_bib52","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2013.04.040","article-title":"Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging","volume":"82","author":"Sudarski","year":"2013","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib53","volume":"vol. 267","author":"Delesalle","year":"2013"},{"key":"10.1016\/j.heliyon.2023.e20700_bib54","doi-asserted-by":"crossref","DOI":"10.1016\/j.acra.2013.12.006","article-title":"Optimization of kiloelectron volt settings in cerebral and cervical dual-energy CT angiography determined with virtual monoenergetic imaging","volume":"21","author":"Schneider","year":"2014","journal-title":"Acad. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib55","doi-asserted-by":"crossref","DOI":"10.1148\/radiol.2483080193","article-title":"Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT","volume":"249","author":"Stolzmann","year":"2008","journal-title":"Radiology"},{"key":"10.1016\/j.heliyon.2023.e20700_bib56","doi-asserted-by":"crossref","DOI":"10.2214\/AJR.11.8033","article-title":"Endoleak detection after endovascular repair of thoracic aortic aneurysm using dual-source dual-energy CT: suitable scanning protocols and potential radiation dose reduction","volume":"200","author":"Flors","year":"2013","journal-title":"Am. J. Roentgenol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib57","doi-asserted-by":"crossref","DOI":"10.1097\/RCT.0b013e31824258cb","article-title":"Sweet spot\u201d for endoleak detection: optimizing contrast to noise using low kev reconstructions from fast-switch kVp dual-energy CT","volume":"36","author":"Maturen","year":"2012","journal-title":"J. Comput. Assist. Tomogr."},{"key":"10.1016\/j.heliyon.2023.e20700_bib58","doi-asserted-by":"crossref","DOI":"10.1148\/rg.332125124","article-title":"Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT","volume":"33","author":"Pessis","year":"2013","journal-title":"Radiographics"},{"key":"10.1016\/j.heliyon.2023.e20700_bib59","doi-asserted-by":"crossref","DOI":"10.1007\/s00234-015-1537-1","article-title":"Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?","volume":"57","author":"de Crop","year":"2015","journal-title":"Neuroradiology"},{"key":"10.1016\/j.heliyon.2023.e20700_bib60","doi-asserted-by":"crossref","DOI":"10.1007\/s00261-016-1023-1","article-title":"Metal implants on CT: comparison of iterative reconstruction algorithms for reduction of metal artifacts with single energy and spectral CT scanning in a phantom model","volume":"42","author":"Fang","year":"2017","journal-title":"Abdominal Radiology"},{"key":"10.1016\/j.heliyon.2023.e20700_bib61","doi-asserted-by":"crossref","DOI":"10.3174\/ajnr.A6238","article-title":"Unintended consequences: review of new artifacts introduced by iterative reconstruction CT metal artifact reduction in spine imaging","author":"Wayer","year":"2019","journal-title":"Am. J. Neuroradiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib62","doi-asserted-by":"crossref","DOI":"10.1136\/neurintsurg-2018-013886","article-title":"Clinical evaluation of volume of interest imaging combined with metal artifact reduction reconstruction techniques in coiling and stent assisted coiling during neurointerventional procedures","volume":"11","author":"Zhang","year":"2019","journal-title":"J. Neurointerventional Surg."},{"key":"10.1016\/j.heliyon.2023.e20700_bib63","doi-asserted-by":"crossref","DOI":"10.1007\/s00330-018-5414-2","article-title":"CT metal artifacts in patients with total hip replacements: for artifact reduction monoenergetic reconstructions and post-processing algorithms are both efficient but not similar","volume":"28","author":"Laukamp","year":"2018","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib64","doi-asserted-by":"crossref","DOI":"10.1007\/s00330-021-07746-8","article-title":"Reduction of CT artifacts from cardiac implantable electronic devices using a combination of virtual monoenergetic images and post-processing algorithms","volume":"31","author":"Pennig","year":"2021","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e20700_bib65","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-020-63574-8","article-title":"Virtual monoenergetic images and post-processing algorithms effectively reduce CT artifacts from intracranial aneurysm treatment","volume":"10","author":"Zopfs","year":"2020","journal-title":"Sci. Rep."},{"key":"10.1016\/j.heliyon.2023.e20700_bib66","doi-asserted-by":"crossref","DOI":"10.1097\/RCT.0000000000000811","article-title":"Effect of virtual monoenergetic images from spectral detector computed tomography on coronary calcium blooming","volume":"42","author":"van Hedent","year":"2018","journal-title":"J. Comput. Assist. Tomogr."},{"key":"10.1016\/j.heliyon.2023.e20700_bib67","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.radi.2022.09.002","article-title":"Noise-optimized virtual monoenergetic reconstructions of dual-energy CT angiographies improve assessability of the lower leg arterial segments in peripheral arterial occlusive disease","volume":"29","author":"Gruschwitz","year":"2023","journal-title":"Radiography"}],"container-title":["Heliyon"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844023079082?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844023079082?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T08:37:12Z","timestamp":1790757432000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405844023079082"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":67,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2023,10]]}},"alternative-id":["S2405844023079082"],"URL":"https:\/\/doi.org\/10.1016\/j.heliyon.2023.e20700","relation":{},"ISSN":["2405-8440"],"issn-type":[{"value":"2405-8440","type":"print"}],"subject":[],"published":{"date-parts":[[2023,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair","name":"articletitle","label":"Article Title"},{"value":"Heliyon","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heliyon.2023.e20700","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"e20700"}}