{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T07:13:25Z","timestamp":1791616405139,"version":"4.3.4"},"reference-count":22,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T00:00:00Z","timestamp":1700438400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82001814"],"award-info":[{"award-number":["82001814"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100014764","name":"China International Medical Foundation","doi-asserted-by":"publisher","award":["Z-2014-07-2101"],"award-info":[{"award-number":["Z-2014-07-2101"]}],"id":[{"id":"10.13039\/501100014764","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["cell.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heliyon"],"published-print":{"date-parts":[[2024,1]]},"DOI":"10.1016\/j.heliyon.2023.e22810","type":"journal-article","created":{"date-parts":[[2023,11,23]],"date-time":"2023-11-23T17:43:57Z","timestamp":1700761437000},"page":"e22810","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Deep learning reconstruction improves the image quality of low-dose temporal bone CT with otitis media and mastoiditis patients"],"prefix":"10.1016","volume":"10","author":[{"given":"Tian-Jiao","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhu-Hua","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Man","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tong","family":"Su","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying-Hao","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhuang-Fei","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9795-9311","authenticated-orcid":false,"given":"Yu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zheng-Yu","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.heliyon.2023.e22810_bib1","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1148\/radiol.2351020895","article-title":"CT of the normal temporal bone: comparison of multi- and single-detector row CT","volume":"235","author":"J\u00e4ger","year":"2005","journal-title":"Radiology"},{"key":"10.1016\/j.heliyon.2023.e22810_bib2","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1097\/MAO.0b013e31819e61ed","article-title":"Automatic identification and 3D rendering of temporal bone anatomy","volume":"30","author":"Noble","year":"2009","journal-title":"Otol. Neurotol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib3","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1007\/s13244-011-0126-z","article-title":"External and middle ear diseases: radiological diagnosis based on clinical signs and symptoms","volume":"3","author":"Trojanowska","year":"2012","journal-title":"Insights Into Imaging"},{"key":"10.1016\/j.heliyon.2023.e22810_bib4","doi-asserted-by":"crossref","first-page":"e325","DOI":"10.1097\/MD.0000000000000325","article-title":"Improving depiction of temporal bone anatomy with low-radiation dose CT by an integrated circuit detector in pediatric patients: a preliminary study","volume":"93","author":"He","year":"2014","journal-title":"Medicine (Baltim.)"},{"key":"10.1016\/j.heliyon.2023.e22810_bib5","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1259\/dmfr\/14139527","article-title":"Image quality and radiation exposure in 320-row temporal bone computed tomography","volume":"39","author":"Bauknecht","year":"2010","journal-title":"Dentomaxillofacial. Radiol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib6","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1177\/0284185118802597","article-title":"Low-dose non-contrast examination of the temporal bone using volumetric 320-row computed tomography","volume":"60","author":"Pirimoglu","year":"2019","journal-title":"Acta Radiol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib7","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1148\/radiol.2303021726","article-title":"Strategies for CT radiation dose optimization","volume":"230","author":"Kalra","year":"2004","journal-title":"Radiology"},{"key":"10.1016\/j.heliyon.2023.e22810_bib8","first-page":"27","article-title":"Strategies for reducing radiation dose in CT","volume":"47","author":"McCollough","year":"2009","journal-title":"Radiol. Clin."},{"key":"10.1016\/j.heliyon.2023.e22810_bib9","doi-asserted-by":"crossref","first-page":"65","DOI":"10.2217\/iim.09.5","article-title":"Radiation dose reduction in computed tomography: techniques and future perspective","volume":"1","author":"Yu","year":"2009","journal-title":"Imag. Med."},{"key":"10.1016\/j.heliyon.2023.e22810_bib10","doi-asserted-by":"crossref","first-page":"5322","DOI":"10.1007\/s00330-019-06183-y","article-title":"Deep learning-based image restoration algorithm for coronary CT angiography","volume":"29","author":"Tatsugami","year":"2019","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib11","doi-asserted-by":"crossref","first-page":"392","DOI":"10.21037\/qims-20-626","article-title":"Deep learning reconstruction versus iterative reconstruction for cardiac CT angiography in a stroke imaging protocol: reduced radiation dose and improved image quality","volume":"11","author":"Bernard","year":"2021","journal-title":"Quant. Imaging Med. Surg."},{"key":"10.1016\/j.heliyon.2023.e22810_bib12","doi-asserted-by":"crossref","first-page":"6163","DOI":"10.1007\/s00330-019-06170-3","article-title":"Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT","volume":"29","author":"Akagi","year":"2019","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib13","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.ejrad.2018.03.004","article-title":"Radiation dose and image conspicuity comparison between conventional 120kVp and 150kVp with spectral beam shaping for temporal bone CT","volume":"102","author":"Kim","year":"2018","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib14","first-page":"37","article-title":"Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102","author":"Valentin","year":"2007","journal-title":"Ann. ICRP"},{"key":"10.1016\/j.heliyon.2023.e22810_bib15","doi-asserted-by":"crossref","first-page":"363","DOI":"10.2307\/2529786","article-title":"An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"10.1016\/j.heliyon.2023.e22810_bib16","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1111\/1754-9485.12596","article-title":"Imaging of the temporal bone in children using low-dose 320-row area detector computed tomography","volume":"61","author":"Tada","year":"2017","journal-title":"J. Med. Imaging Radiat. Oncol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib17","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1007\/s11604-014-0376-z","article-title":"Model-based iterative reconstruction for detection of subtle hypoattenuation in early cerebral infarction: a phantom study","volume":"33","author":"Nishizawa","year":"2014","journal-title":"Jpn. J. Radiol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib18","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.ejmp.2015.09.011","article-title":"Objective assessment of low contrast detectability in computed tomography with Channelized Hotelling Observer","volume":"32","author":"Racine","year":"2016","journal-title":"Phys. Med."},{"key":"10.1016\/j.heliyon.2023.e22810_bib19","doi-asserted-by":"crossref","first-page":"5252","DOI":"10.1007\/s00330-017-4825-9","article-title":"Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages","volume":"27","author":"Euler","year":"2017","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib20","article-title":"Evaluation of the depiction ability of the microanatomy of the temporal bone in quarter-detector CT: model-based iterative reconstruction vs hybrid iterative reconstruction","volume":"98","author":"Kurokawa","year":"2019","journal-title":"Medicine (Baltim.)"},{"key":"10.1016\/j.heliyon.2023.e22810_bib21","doi-asserted-by":"crossref","first-page":"4016","DOI":"10.1007\/s00330-018-5988-8","article-title":"Full model-based iterative reconstruction (MBIR) in abdominal CT increases objective image quality, but decreases subjective acceptance","volume":"29","author":"Laurent","year":"2019","journal-title":"Eur. Radiol."},{"key":"10.1016\/j.heliyon.2023.e22810_bib22","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.3174\/ajnr.A2524","article-title":"Low-dose temporal bone CT in infants and young children: effective dose and image quality","volume":"32","author":"Nauer","year":"2011","journal-title":"AJNR Am. J. Neuroradiol."}],"container-title":["Heliyon"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844023100181?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844023100181?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T04:28:44Z","timestamp":1790656124000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405844023100181"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,1]]}},"alternative-id":["S2405844023100181"],"URL":"https:\/\/doi.org\/10.1016\/j.heliyon.2023.e22810","relation":{},"ISSN":["2405-8440"],"issn-type":[{"value":"2405-8440","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Deep learning reconstruction improves the image quality of low-dose temporal bone CT with otitis media and mastoiditis patients","name":"articletitle","label":"Article Title"},{"value":"Heliyon","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heliyon.2023.e22810","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"e22810"}}