{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T22:36:00Z","timestamp":1790289360808,"version":"4.1.0"},"reference-count":42,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,5,20]],"date-time":"2024-05-20T00:00:00Z","timestamp":1716163200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["cell.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heliyon"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1016\/j.heliyon.2024.e31657","type":"journal-article","created":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T14:07:27Z","timestamp":1716473247000},"page":"e31657","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Prediction method of centrifugal pump running in turbine mode based on losses analysis"],"prefix":"10.1016","volume":"10","author":[{"given":"Abeyo Mayo","family":"Tchada","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9632-5667","authenticated-orcid":false,"given":"Davi Edson","family":"Sales E Souza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nsah-ko","family":"Tchoumbou\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5559-5580","authenticated-orcid":false,"given":"Andr\u00e9 Luiz","family":"Amarante Mesquita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Hendrick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.heliyon.2024.e31657_br0010","author":"Sullivan"},{"key":"10.1016\/j.heliyon.2024.e31657_br0020","doi-asserted-by":"crossref","unstructured":"B. Ummels, E. Pelgrum, W. Kling, Integration of large-scale wind power and use of energy storage in the Netherlands electricity supply, 2007, Special issue of IET Renewable Generation-selected papers from EWEC.","DOI":"10.1049\/iet-rpg:20070056"},{"key":"10.1016\/j.heliyon.2024.e31657_br0030","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.enpol.2013.06.061","article-title":"Development of China's pumped storage plant and related policy analysis","author":"Ming","year":"2013","journal-title":"Energy Policy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0040","first-page":"36","article-title":"Progress and prospective on the police system of renewable energy in China","author":"Ming","year":"2013","journal-title":"Renew. Sustain. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0050","first-page":"64","article-title":"Performance improvement of forward-curved impeller with an adequate outlet swirl using in centrifugal pump as turbine","author":"Wang","year":"2023","journal-title":"Renew. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0060","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.renene.2023.03.005","article-title":"Broadening the operating range of pump-turbine to deep-part load by runner optimization","author":"Hu","year":"2023","journal-title":"Renew. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0070","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.energy.2019.01.162","article-title":"Theoretical model of energy performance prediction and BEP determination for centrifugal pump as turbine","author":"Liu","year":"2019","journal-title":"Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0080","doi-asserted-by":"crossref","DOI":"10.3390\/w12041175","article-title":"A performance pre diction model for pumps as turbines (PATs)","author":"Fontanella","year":"2020","journal-title":"Water"},{"key":"10.1016\/j.heliyon.2024.e31657_br0090","first-page":"2839","article-title":"Running centrifugal pumps as micro-hydro turbines performances prediction using the area ratio method","author":"Burton","year":"1992","journal-title":"Renew. Energy, TechnolEnviron"},{"key":"10.1016\/j.heliyon.2024.e31657_br0100","first-page":"101","article-title":"Utilizzazione dell'energia idrica su piccola scala: pompa come turbina","author":"Ventrone","year":"1982","journal-title":"Energ. Electr."},{"key":"10.1016\/j.heliyon.2024.e31657_br0110","article-title":"Self-validated calculation of characteristics of Francis turbine and the mechanism of the s-shape the operational instability","author":"Zhang","year":"2012","journal-title":"IOP Conf. Ser. Earth Environ. Sci."},{"key":"10.1016\/j.heliyon.2024.e31657_br0120","article-title":"Analysis about losses of centrifugal pump by Matlab","author":"Shastri","year":"2014","journal-title":"Int. J. Comput. Eng. Res."},{"key":"10.1016\/j.heliyon.2024.e31657_br0130","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.renene.2017.03.054","article-title":"The method for determining blade inlet angle of special impeller using in turbine mode of centrifugal pump as turbine","author":"Wang","year":"2017","journal-title":"Renew. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0140","article-title":"Numerical study of the energy flow characteristics of multi-stage pump as turbines","author":"Sikun","year":"2022","journal-title":"Processes"},{"key":"10.1016\/j.heliyon.2024.e31657_br0150","series-title":"Centrifugal Pumps","author":"Gulich","year":"2014"},{"key":"10.1016\/j.heliyon.2024.e31657_br0160","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.energy.2016.03.122","article-title":"Predictive model estimating the performances of centrifugal pumps used as turbines","author":"Barbarelli","year":"2016","journal-title":"Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0170","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/j.apenergy.2019.03.018","article-title":"Pump as turbine applied to micro energy storage and s- mart water grids: a case study","author":"Morabito","year":"2019","journal-title":"Appl. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0180","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/j.rser.2017.04.071","article-title":"Investigation on pump as turbine (PAT) technical aspects for micro hydropower schemes: a state of the art review","author":"Binama","year":"2017","journal-title":"Renew. Sustain. Energy Rev."},{"key":"10.1016\/j.heliyon.2024.e31657_br0190","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.1016\/j.renene.2020.08.108","article-title":"Selection, control and techno-economic feasibility of pumps as turbines in water distribution networks","author":"Stefanizzi","year":"2020","journal-title":"Renew. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0200","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1016\/j.rser.2014.12.040","article-title":"Pumped hydro energy storage system: a technological review","author":"Rehman","year":"2015","journal-title":"Renew. Sustain. Energy Rev."},{"key":"10.1016\/j.heliyon.2024.e31657_br0220","doi-asserted-by":"crossref","first-page":"2558","DOI":"10.1016\/j.rser.2012.01.068","article-title":"The role of pumped storage systems towards the large scale wind integration in the Greek power supply system","author":"Caralis","year":"2012","journal-title":"Renew. Sustain. Energy Rev."},{"key":"10.1016\/j.heliyon.2024.e31657_br0230","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1049\/iet-rpg.2008.0071","article-title":"Operating policies for wind-pumped storage hybrid power stations in island grids","author":"Papaefthimiou","year":"2009","journal-title":"IET Renew. Power Gener."},{"key":"10.1016\/j.heliyon.2024.e31657_br0240","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1109\/TSTE.2010.2059053","article-title":"A wind-hydro-pumped storage station leading to high RES penetration in the autonomous island system of ikaria","author":"Papaefthimiou","year":"2010","journal-title":"IEEE Trans. Sustain. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0250","series-title":"Application of Pumped Storage to Increase Renewable Energy Penetration in Autonomous Island Systems","first-page":"295","author":"Papaefthimiou","year":"2012"},{"key":"10.1016\/j.heliyon.2024.e31657_br0260","doi-asserted-by":"crossref","DOI":"10.1016\/j.apenergy.2023.121246","article-title":"Optimal hydraulic energy harvesting strategy for PaT installation in water distribution networks","author":"Stefanizzi","year":"2023","journal-title":"Appl. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0270","first-page":"121","article-title":"Internal hydraulic analysis of impeller rounding in centrifugal pumps as turbines","author":"Singh","year":"2010","journal-title":"Exp. Therm. Fluid Sci."},{"key":"10.1016\/j.heliyon.2024.e31657_br0280","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.compfluid.2012.07.009","article-title":"Effects of impeller trimming influencing pump as turbine","author":"Yang","year":"2012","journal-title":"Comput. Fluids"},{"key":"10.1016\/j.heliyon.2024.e31657_br0290","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.renene.2017.03.054","article-title":"The method for determining blade inlet angle of special impeller using in turbine mode of centrifugal pump as turbine","author":"Wang","year":"2017","journal-title":"Renew. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0300","first-page":"140","article-title":"Streamline similarity method for flow distributions and shock losses at the impeller inlet of the centrifugal pump","author":"Zhang","year":"2017","journal-title":"J. Hydrodyn."},{"key":"10.1016\/j.heliyon.2024.e31657_br0310","article-title":"Geometrical optimization of pump as turbine (pat) impellers for enhancing energy efficiency with 1d theory","author":"Wang","year":"2020","journal-title":"Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0320","series-title":"Optimization of internal hydraulics and of system design for pumps as turbines with field implementation and evaluation","author":"Singh","year":"2005"},{"key":"10.1016\/j.heliyon.2024.e31657_br0340","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1243\/PIME_PROC_1994_208_009_02","article-title":"The turbine performance of centrifugal pumps: a comparison of prediction methods","author":"William","year":"1994","journal-title":"J. Power Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0350","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/j.renene.2012.06.002","article-title":"Theoretical, numerical and experimental prediction of pump as turbine performance","author":"Yang","year":"2012","journal-title":"Renew. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0360","first-page":"59","article-title":"Direct and reverse flow condition in radial flow hydraulic turbomachines","author":"Ventrone","year":"2000","journal-title":"J. Power Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0370","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.renene.2018.12.077","article-title":"Blade trailing edge position influencing pump as turbine (pat) pressure field under part-load conditions","author":"Binama","year":"2019","journal-title":"Renew. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0380","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1016\/j.renene.2021.04.112","article-title":"Numerical investigation on the volute cutwater for pumps running in turbine mode","author":"Morabito","year":"2021","journal-title":"Renew. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0390","first-page":"358","article-title":"Numerical simulation on end suction centrifugal pump running in inverse flow for microhydro applications","author":"Aslan","year":"2015","journal-title":"Appl. Mech. Mater."},{"key":"10.1016\/j.heliyon.2024.e31657_br0400","first-page":"373","article-title":"Numerical investigation of a centrifugal pump running in reverse mode","author":"Jhonifer","year":"2010","journal-title":"J. Power Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0410","first-page":"144","article-title":"A new approach for predicting pat- pumps operating point from direct pumping mode characteristics","author":"Pascoa","year":"2012","journal-title":"J. Sci. Ind. Res."},{"key":"10.1016\/j.heliyon.2024.e31657_br0420","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1007\/s11269-022-03421-9","article-title":"Pressure regulation in a water distribution network using pumps as turbines at variable speed for energy recovery","author":"Souza","year":"2023","journal-title":"Water Resour. Manag."},{"key":"10.1016\/j.heliyon.2024.e31657_br0430","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/j.apenergy.2019.04.123","article-title":"Experimental and numerical assessment of a methodology for performance prediction of Pumps-as-Turbines (PaTs) operating in off design conditions","author":"Rossi","year":"2019","journal-title":"Appl. Energy"},{"key":"10.1016\/j.heliyon.2024.e31657_br0440","series-title":"Improved Planning of Energy Recovery in Water Systems Using a New Analytic Approach to PAT Performance Curves","first-page":"468","author":"Perez","year":"2020"}],"container-title":["Heliyon"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024076886?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024076886?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T20:54:49Z","timestamp":1787604889000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405844024076886"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6]]},"references-count":42,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["S2405844024076886"],"URL":"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e31657","relation":{},"ISSN":["2405-8440"],"issn-type":[{"value":"2405-8440","type":"print"}],"subject":[],"published":{"date-parts":[[2024,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Prediction method of centrifugal pump running in turbine mode based on losses analysis","name":"articletitle","label":"Article Title"},{"value":"Heliyon","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e31657","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"e31657"}}