{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T06:01:12Z","timestamp":1793858472933,"version":"4.6.1"},"reference-count":31,"publisher":"Elsevier BV","issue":"18","license":[{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,9,19]],"date-time":"2024-09-19T00:00:00Z","timestamp":1726704000000},"content-version":"vor","delay-in-days":18,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["cell.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heliyon"],"published-print":{"date-parts":[[2024,9]]},"DOI":"10.1016\/j.heliyon.2024.e38209","type":"journal-article","created":{"date-parts":[[2024,9,20]],"date-time":"2024-09-20T12:30:29Z","timestamp":1726835429000},"page":"e38209","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Design and study of additively manufactured Three periodic minimal surface (TPMS) structured porous titanium interbody cage"],"prefix":"10.1016","volume":"10","author":[{"given":"Kun","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ChunYan","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"QiuJiang","family":"Wei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"XinRui","family":"Gou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"FuHuan","family":"Chu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MengJie","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"LinHui","family":"Qiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0347-9291","authenticated-orcid":false,"given":"ShiQi","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.heliyon.2024.e38209_bib1","doi-asserted-by":"crossref","first-page":"7546","DOI":"10.1038\/s41598-022-11551-8","article-title":"A systematic review and meta-analysis of fusion rate enhancements and bone graft options for spine surgery","volume":"12","author":"Tavares","year":"2022","journal-title":"Sci. Rep."},{"issue":"1","key":"10.1016\/j.heliyon.2024.e38209_bib2","doi-asserted-by":"crossref","first-page":"E16","DOI":"10.3171\/2016.8.FOCUS16112","article-title":"Bone graft options for spinal fusion following resection of spinal column tumors: systematic review and meta-analysis","volume":"42","author":"Elder","year":"2017","journal-title":"Neurosurg. Focus"},{"issue":"9","key":"10.1016\/j.heliyon.2024.e38209_bib3","doi-asserted-by":"crossref","first-page":"E528","DOI":"10.1097\/BSD.0b013e3182aab2bf","article-title":"Fusion rates of different anterior grafts in thoracolumbar fractures","volume":"28","author":"Antoni","year":"2015","journal-title":"J. Spinal Disord. Tech."},{"issue":"3","key":"10.1016\/j.heliyon.2024.e38209_bib4","doi-asserted-by":"crossref","first-page":"307","DOI":"10.3390\/mi12030307","article-title":"Design of customize interbody fusion cages of Ti64ELI with gradient porosity by selective laser melting process","volume":"12","author":"Pan","year":"2021","journal-title":"Micromachines"},{"key":"10.1016\/j.heliyon.2024.e38209_bib5","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1007\/s00586-021-06748-w","article-title":"Titanium (Ti) cages may be superior to polyetheretherketone (PEEK) cages in lumbar interbody fusion: a systematic review and meta-analysis of clinical and radiological outcomes of spinal interbody fusions using Ti versus PEEK cages","volume":"30","author":"Tan","year":"2021","journal-title":"Eur. Spine J."},{"issue":"2","key":"10.1016\/j.heliyon.2024.e38209_bib6","doi-asserted-by":"crossref","first-page":"451","DOI":"10.14245\/ns.2346244.122","article-title":"Three-dimensional-printed titanium versus polyetheretherketone cages for lumbar interbody fusion: a systematic review of comparative in vitro, animal, and human studies","volume":"20","author":"Patel","year":"2023","journal-title":"Neurospine"},{"issue":"3","key":"10.1016\/j.heliyon.2024.e38209_bib7","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.3390\/ma7031709","article-title":"New developments of Ti-based alloys for biomedical applications","volume":"7","author":"Li","year":"2014","journal-title":"Materials"},{"key":"10.1016\/j.heliyon.2024.e38209_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/j.matdes.2021.110361","article-title":"The ability of a novel biomimetic titanium alloy cage in avoiding subsidence and promoting fusion: a goat spine model study","volume":"213","author":"Wang","year":"2022","journal-title":"Mater. Des."},{"issue":"5","key":"10.1016\/j.heliyon.2024.e38209_bib9","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1108\/RPJ-07-2011-0067","article-title":"Production of customized hip stem prostheses\u2013a comparison between conventional machining and electron beam melting (EBM)","volume":"19","author":"Cronsk\u00e4r","year":"2013","journal-title":"Rapid Prototyp. J."},{"key":"10.1016\/j.heliyon.2024.e38209_bib10","doi-asserted-by":"crossref","DOI":"10.1016\/j.clinbiomech.2022.105764","article-title":"Biomechanical comparison of subsidence performance among three modern porous lateral cage designs[J]","volume":"99","author":"Yee-Yanagishita","year":"2022","journal-title":"Clin. BioMech."},{"key":"10.1016\/j.heliyon.2024.e38209_bib11","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2020.103700","article-title":"Design of a patient-specific mandible reconstruction implant with dental prosthesis for metal 3D printing using integrated weighted topology optimization and finite element analysis","volume":"105","author":"Li","year":"2020","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.heliyon.2024.e38209_bib12","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.jmrt.2022.05.001","article-title":"Application of finite element analysis for optimizing selection and design of Ti-based bimetallic alloys for fractures and tissues rehabilitation: a review","volume":"19","author":"Alaneme","year":"2022","journal-title":"J. Mater. Res. Technol."},{"key":"10.1016\/j.heliyon.2024.e38209_bib13","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.scriptamat.2019.01.022","article-title":"Design of metallic bone by additive manufacturing","volume":"164","author":"Alabort","year":"2019","journal-title":"Scripta Mater."},{"key":"10.1016\/j.heliyon.2024.e38209_bib14","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.actbio.2019.07.049","article-title":"Synthetic bone: design by additive manufacturing","volume":"97","author":"Barba","year":"2019","journal-title":"Acta Biomater."},{"issue":"1","key":"10.1016\/j.heliyon.2024.e38209_bib15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12967-019-1834-2","article-title":"Design and biomechanical characteristics of porous meniscal implant structures using triply periodic minimal surfaces","volume":"17","author":"Zhu","year":"2019","journal-title":"J. Transl. Med."},{"issue":"1","key":"10.1016\/j.heliyon.2024.e38209_bib16","doi-asserted-by":"crossref","DOI":"10.1080\/17452759.2023.2170890","article-title":"Controllable three-dimension auxetic structure design strategies based on triply periodic minimal surfaces and the application in hip implant","volume":"18","author":"Liu","year":"2023","journal-title":"Virtual Phys. Prototyp."},{"key":"10.1016\/j.heliyon.2024.e38209_bib17","doi-asserted-by":"crossref","DOI":"10.1016\/j.compstruct.2021.113801","article-title":"Quasi-static and dynamic compressive behaviour of sheet TPMS cellular structures","volume":"266","author":"Novak","year":"2021","journal-title":"Compos. Struct."},{"key":"10.1016\/j.heliyon.2024.e38209_bib18","doi-asserted-by":"crossref","DOI":"10.1016\/j.ijmecsci.2022.108092","article-title":"TPMS-based interpenetrating lattice structures: design, mechanical properties and multiscale optimization","volume":"244","author":"Zhao","year":"2023","journal-title":"Int. J. Mech. Sci."},{"issue":"1","key":"10.1016\/j.heliyon.2024.e38209_bib19","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1186\/s13018-023-04310-6","article-title":"A novel artificial vertebral implant with Gyroid porous structures for reducing the subsidence and mechanical failure rate after vertebral body replacement","volume":"18","author":"Shang","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"10.1016\/j.heliyon.2024.e38209_bib20","series-title":"Infinite Periodic Minimal Surfaces without self-intersections[R]","author":"Schoen","year":"1970"},{"issue":"23","key":"10.1016\/j.heliyon.2024.e38209_bib21","doi-asserted-by":"crossref","DOI":"10.1073\/pnas.2101357118","article-title":"Evolution of single gyroid photonic crystals in bird feathers[J]","volume":"118","author":"Saranathan","year":"2021","journal-title":"Proc. Natl. Acad. Sci. USA"},{"issue":"26","key":"10.1016\/j.heliyon.2024.e38209_bib22","doi-asserted-by":"crossref","first-page":"11676","DOI":"10.1073\/pnas.0909616107","article-title":"Structure, function, and self-assembly of single network gyroid (I 4132) photonic crystals in butterfly wing scales","volume":"107","author":"Saranathan","year":"2010","journal-title":"Proc. Natl. Acad. Sci. USA"},{"issue":"8","key":"10.1016\/j.heliyon.2024.e38209_bib23","doi-asserted-by":"crossref","first-page":"3319","DOI":"10.1021\/acsabm.3c00383","article-title":"3D-printed PEEK\/silicon nitride scaffolds with a triply periodic minimal surface structure for spinal fusion implants","volume":"6","author":"Du","year":"2023","journal-title":"ACS Appl. Bio Mater."},{"key":"10.1016\/j.heliyon.2024.e38209_bib24","doi-asserted-by":"crossref","DOI":"10.1016\/j.ijmecsci.2019.105262","article-title":"Mechanical and energy absorption characteristics of additively manufactured functionally graded sheet lattice structures with minimal surfaces","volume":"167","author":"Zhao","year":"2020","journal-title":"International Journal of Mechanical Sciences"},{"key":"10.1016\/j.heliyon.2024.e38209_bib25","series-title":"Research on Modeling Method of Porous Structure [D]","first-page":"21","author":"Yang","year":"2017"},{"issue":"27","key":"10.1016\/j.heliyon.2024.e38209_bib26","doi-asserted-by":"crossref","first-page":"5474","DOI":"10.1016\/j.biomaterials.2005.02.002","article-title":"Porosity of 3D biomaterial scaffolds and osteogenesis","volume":"26","author":"Karageorgiou","year":"2005","journal-title":"Biomaterials"},{"issue":"3","key":"10.1016\/j.heliyon.2024.e38209_bib27","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1111\/j.1601-6343.2005.00329.x","article-title":"Engineering craniofacial scaffolds","volume":"8","author":"Hollister","year":"2010","journal-title":"Orthod. Craniofac. Res."},{"key":"10.1016\/j.heliyon.2024.e38209_bib28","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.matdes.2018.05.058","article-title":"Effective design and simulation of surface-based lattice structures featuring volume fraction and cell type grading","volume":"155","author":"Maskery","year":"2018","journal-title":"Mater. Des."},{"key":"10.1016\/j.heliyon.2024.e38209_bib29","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.actbio.2017.02.024","article-title":"Additively manufactured metallic porous biomaterials based on minimal surfaces: a unique combination of topological, mechanical, and mass transport properties","volume":"53","author":"Bobbert","year":"2017","journal-title":"Acta Biomater."},{"key":"10.1016\/j.heliyon.2024.e38209_bib30","series-title":"10993\u20135: 2009 Biological Evaluation of Medical Devices\u2014Part 5: Tests for in Vitro Cytotoxicity","first-page":"34","author":"Iso","year":"2009"},{"key":"10.1016\/j.heliyon.2024.e38209_bib31","doi-asserted-by":"crossref","DOI":"10.1016\/j.matdes.2021.109838","article-title":"Architected implant designs for long bones: advantages of minimal surface-based topologies","volume":"207","author":"Hsieh","year":"2021","journal-title":"Mater. Des."}],"container-title":["Heliyon"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024142405?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024142405?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T20:20:24Z","timestamp":1790713224000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405844024142405"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9]]},"references-count":31,"journal-issue":{"issue":"18","published-print":{"date-parts":[[2024,9]]}},"alternative-id":["S2405844024142405"],"URL":"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e38209","relation":{},"ISSN":["2405-8440"],"issn-type":[{"value":"2405-8440","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Design and study of additively manufactured Three periodic minimal surface (TPMS) structured porous titanium interbody cage","name":"articletitle","label":"Article Title"},{"value":"Heliyon","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e38209","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"e38209"}}