{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T22:02:26Z","timestamp":1776376946960,"version":"3.51.2"},"reference-count":20,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,11,27]],"date-time":"2024-11-27T00:00:00Z","timestamp":1732665600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["cell.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heliyon"],"published-print":{"date-parts":[[2025,1]]},"DOI":"10.1016\/j.heliyon.2024.e40793","type":"journal-article","created":{"date-parts":[[2024,12,6]],"date-time":"2024-12-06T12:01:30Z","timestamp":1733486490000},"page":"e40793","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Conventional endotracheal tubes versus polymer-coated tubes in ventilator-associated pneumonia development: A systematic review and meta-analysis"],"prefix":"10.1016","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9192-533X","authenticated-orcid":false,"given":"Oscar In\u00e1cio","family":"de Mendon\u00e7a Bisneto","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luanna Paula","family":"Garcez de Carvalho Feitoza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Larissa Calixto","family":"Hespanhol","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S\u00e1vio Benvindo","family":"Ferreira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Caroline Serafim","family":"Dagostin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roberto Augusto","family":"Mazetto Silva Vieira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucas Alencar","family":"Queiroz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucas","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taniela Marli","family":"Bes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ho Yeh","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.heliyon.2024.e40793_bib1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13613-021-00961-y","article-title":"Prevention of ventilator-associated pneumonia by noble metal coating of endotracheal tubes: a multi-center, randomized, double-blind study","volume":"12","author":"Damas","year":"2022","journal-title":"Ann. Intensive Care"},{"issue":"11","key":"10.1016\/j.heliyon.2024.e40793_bib2","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1164\/rccm.200705-761OC","article-title":"Influence of an endotracheal tube with polyurethane cuff and subglottic secretion drainage on pneumonia","volume":"176","author":"Lorente","year":"2007","journal-title":"Am. J. Respir. Crit. Care Med."},{"issue":"7","key":"10.1016\/j.heliyon.2024.e40793_bib3","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1001\/jama.300.7.805","article-title":"Silver-coated endotracheal tubes and incidence of ventilator-associated pneumonia: the NASCENT randomized trial","volume":"300","author":"Kollef","year":"2008","journal-title":"JAMA"},{"issue":"3","key":"10.1016\/j.heliyon.2024.e40793_bib4","first-page":"167","article-title":"Efficacy of noble metal\u2013alloy endotracheal tubes in ventilator-associated pneumonia prevention: a randomized clinical trial","volume":"39","author":"Tincu","year":"2022","journal-title":"Balkan Med. J."},{"issue":"6","key":"10.1016\/j.heliyon.2024.e40793_bib5","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1164\/rccm.201408-1398OC","article-title":"Randomized intubation with polyurethane or conical cuffs to prevent pneumonia in ventilated patients","volume":"191","author":"Philippart","year":"2015","journal-title":"Am. J. Respir. Crit. Care Med."},{"issue":"4","key":"10.1016\/j.heliyon.2024.e40793_bib6","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.jtcvs.2007.08.052","article-title":"Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: a pilot study","volume":"135","author":"Poelaert","year":"2008","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"10.1016\/j.heliyon.2024.e40793_bib7","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"issue":"6","key":"10.1016\/j.heliyon.2024.e40793_bib8","doi-asserted-by":"crossref","first-page":"2115","DOI":"10.1378\/chest.122.6.2115","article-title":"Epidemiology and outcomes of ventilator-associated pneumonia in a large US database","volume":"122","author":"Rello","year":"2002","journal-title":"Chest"},{"issue":"6","key":"10.1016\/j.heliyon.2024.e40793_bib9","doi-asserted-by":"crossref","first-page":"433","DOI":"10.7326\/0003-4819-129-6-199809150-00002","article-title":"Incidence of and risk factors for ventilator-associated pneumonia in critically ill patients","volume":"129","author":"Cook","year":"1998","journal-title":"Ann. Intern. Med."},{"issue":"11","key":"10.1016\/j.heliyon.2024.e40793_bib10","doi-asserted-by":"crossref","first-page":"2086","DOI":"10.1007\/s00134-003-1991-9","article-title":"Ventilator-associated pneumonia: caveats for benchmarking","volume":"29","author":"Eggimann","year":"2003","journal-title":"Intensive Care Med."},{"issue":"12","key":"10.1016\/j.heliyon.2024.e40793_bib11","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1056\/NEJM199803193381203","article-title":"A comparison of sucralfate and ranitidine for the prevention of upper gastrointestinal bleeding in patients requiring mechanical ventilation","volume":"338","author":"Cook","year":"1998","journal-title":"N. Engl. J. Med."},{"issue":"4","key":"10.1016\/j.heliyon.2024.e40793_bib12","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1164\/rccm.200405-644ST","article-title":"Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia","volume":"171","year":"2005","journal-title":"Am. J. Respir. Crit. Care Med."},{"issue":"1","key":"10.1016\/j.heliyon.2024.e40793_bib13","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1378\/chest.130.1.251","article-title":"Preventing ventilator-associated pneumonia in adults: sowing seeds of change","volume":"130","author":"Craven","year":"2006","journal-title":"Chest"},{"issue":"suppl 1","key":"10.1016\/j.heliyon.2024.e40793_bib14","first-page":"S31","article-title":"Ventilator associated pneumonia: perspectives on the burden of illness","volume":"26","author":"Cook","year":"2000","journal-title":"Intensive Care Med."},{"issue":"4","key":"10.1016\/j.heliyon.2024.e40793_bib15","doi-asserted-by":"crossref","first-page":"305","DOI":"10.7326\/0003-4819-141-4-200408170-00011","article-title":"Evidencebased clinical practice guideline for the prevention of ventilator-associated pneumonia","volume":"141","author":"Dodek","year":"2004","journal-title":"Ann. Intern. Med."},{"issue":"RR-3","key":"10.1016\/j.heliyon.2024.e40793_bib16","first-page":"1","article-title":"Guidelines for preventing healthcare-associated pneumonia, 2003: recommendations of CDC and the healthcare infection control practices advisory committee","volume":"53","author":"Tablan","year":"2004","journal-title":"MMWR Recomm. Rep. (Morb. Mortal. Wkly. Rep.)"},{"issue":"10","key":"10.1016\/j.heliyon.2024.e40793_bib17","first-page":"3547","article-title":"An educational intervention to reduce ventilator-associated pneumonia in an integrated health system: a comparison of effects","volume":"28","author":"Babcock","year":"2000","journal-title":"Crit. Care Med."},{"issue":"2","key":"10.1016\/j.heliyon.2024.e40793_bib19","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1378\/chest.122.2.656","article-title":"KollefMH. Why do physicians not follow evidence-based guidelines for preventing ventilator-associated pneumonia? a survey based on the opinions of an international panel of intensivists","volume":"122","author":"Rello","year":"2002","journal-title":"Chest"},{"key":"10.1016\/j.heliyon.2024.e40793_bib20","article-title":"RoB 2: a revised tool for assessing risk of bias in randomised trials","volume":"366","author":"Sterne","year":"2019","journal-title":"BMJ"},{"issue":"14","key":"10.1016\/j.heliyon.2024.e40793_bib21","doi-asserted-by":"crossref","first-page":"5034","DOI":"10.3390\/ma16145034","article-title":"Antimicrobial solutions for endotracheal tubes in prevention of ventilator-associated pneumonia","volume":"16","author":"Marcut","year":"2023","journal-title":"Materials"}],"container-title":["Heliyon"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024168247?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024168247?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T21:15:26Z","timestamp":1776374126000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405844024168247"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"alternative-id":["S2405844024168247"],"URL":"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e40793","relation":{},"ISSN":["2405-8440"],"issn-type":[{"value":"2405-8440","type":"print"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Conventional endotracheal tubes versus polymer-coated tubes in ventilator-associated pneumonia development: A systematic review and meta-analysis","name":"articletitle","label":"Article Title"},{"value":"Heliyon","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e40793","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"e40793"}}