{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T01:59:17Z","timestamp":1791424757451,"version":"4.3.3"},"reference-count":36,"publisher":"Elsevier BV","issue":"24","license":[{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T00:00:00Z","timestamp":1733270400000},"content-version":"vor","delay-in-days":3,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["cell.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heliyon"],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1016\/j.heliyon.2024.e40995","type":"journal-article","created":{"date-parts":[[2024,12,9]],"date-time":"2024-12-09T11:43:36Z","timestamp":1733744616000},"page":"e40995","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Detection and continuous monitoring of moisture content in transformer oil using fractal-based capacitive sensor"],"prefix":"10.1016","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-7531-0738","authenticated-orcid":false,"given":"Muhammad Fahad","family":"Naveed","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akasha","family":"Amaar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saad Saleem","family":"Khan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad","family":"Omar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Larkin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.heliyon.2024.e40995_br0010","series-title":"Springer Handbook of Power Systems","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1007\/978-981-32-9938-2_7","article-title":"Transformers","author":"Werle","year":"2021"},{"key":"10.1016\/j.heliyon.2024.e40995_br0020","doi-asserted-by":"crossref","DOI":"10.1016\/j.ijepes.2019.105743","article-title":"Thermal performance of transformers filled with environmentally friendly oils under various loading conditions","volume":"118","author":"Salama","year":"2020","journal-title":"Int. J. Electr. Power Energy Syst."},{"issue":"6","key":"10.1016\/j.heliyon.2024.e40995_br0030","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1109\/MEI.2002.1161455","article-title":"Review of condition assessment of power transformers in service","volume":"18","author":"Wang","year":"2002","journal-title":"IEEE Electr. Insul. Mag."},{"issue":"2","key":"10.1016\/j.heliyon.2024.e40995_br0040","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1109\/61.4306","article-title":"Failure analysis of ehv transformers","volume":"3","author":"Kogan","year":"1988","journal-title":"IEEE Trans. Power Deliv."},{"key":"10.1016\/j.heliyon.2024.e40995_br0050","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.engfailanal.2015.06.002","article-title":"Failure analysis of power transformer for effective maintenance planning in electric utilities","volume":"55","author":"Murugan","year":"2015","journal-title":"Eng. Fail. Anal."},{"key":"10.1016\/j.heliyon.2024.e40995_br0060","series-title":"Minutes of the Sixty-First Annual International Conference of Doble Clients","article-title":"Experience with the refurbishment and life extension of large power transformers","author":"Sokolov","year":"1994"},{"key":"10.1016\/j.heliyon.2024.e40995_br0070","series-title":"1999 Eleventh International Symposium on High Voltage Engineering","first-page":"94","article-title":"Failures in power system transformers and appropriate monitoring techniques","volume":"vol. 1","author":"Minhas","year":"1999"},{"key":"10.1016\/j.heliyon.2024.e40995_br0080","series-title":"2021 3rd International Conference on Electrical Engineering (EECon)","first-page":"31","article-title":"Influence of water and powder contaminants on dielectric strength of transformer oil","author":"Abeyrathna","year":"2021"},{"key":"10.1016\/j.heliyon.2024.e40995_br0090","series-title":"W. G. P. in Oil International Conference on Large High Voltage Electric Systems","article-title":"Effect of particles on transformer dielectric strength","author":"Antonov","year":"2000"},{"issue":"4","key":"10.1016\/j.heliyon.2024.e40995_br0100","doi-asserted-by":"crossref","first-page":"1920","DOI":"10.3390\/en16041920","article-title":"Water content in transformer insulation system: a review on the detection and quantification methods","volume":"16","author":"Arsad","year":"2023","journal-title":"Energies"},{"issue":"5","key":"10.1016\/j.heliyon.2024.e40995_br0110","doi-asserted-by":"crossref","first-page":"2455","DOI":"10.1109\/TDEI.2015.004796","article-title":"Aging degree evaluation for paper-oil insulation using the recovery voltage method","volume":"22","author":"Wolny","year":"2015","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"10.1016\/j.heliyon.2024.e40995_br0120","first-page":"430","article-title":"Modeling of polarization in oil-paper insulation using recovery voltage measurements","volume":"6","author":"Filipovi\u0107-Gr\u010di\u0107","year":"2011","journal-title":"Int Rev. Electrical Eng."},{"key":"10.1016\/j.heliyon.2024.e40995_br0130","series-title":"1998 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No. 98CH36257)","first-page":"345","article-title":"Practical foundations of the rvm (recovery voltage method for oil\/paper insulation diagnosis)","volume":"vol. 1","author":"Csepes","year":"1998"},{"key":"10.1016\/j.heliyon.2024.e40995_br0140","series-title":"Karl Fischer Titration Usage and Uncertainty Evaluation","first-page":"1","author":"Aro","year":"2016"},{"key":"10.1016\/j.heliyon.2024.e40995_br0150","series-title":"Pharmaceutical Sciences Encyclopedia: Drug Discovery, Development, and Manufacturing","first-page":"1","article-title":"Water determination by Karl Fischer titration","author":"Margreth","year":"2010"},{"key":"10.1016\/j.heliyon.2024.e40995_br0160","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1007\/s00216-003-1865-6","article-title":"The determination of water in crude oil and transformer oil reference materials","volume":"376","author":"Margolis","year":"2003","journal-title":"Anal. Bioanal. Chem."},{"issue":"15","key":"10.1016\/j.heliyon.2024.e40995_br0170","doi-asserted-by":"crossref","first-page":"3100","DOI":"10.1021\/ac970034y","article-title":"Diaphragm-free cell for trace determination of water based on the Karl Fischer reaction using continuous coulometric titration","volume":"69","author":"Cedergren","year":"1997","journal-title":"Anal. Chem."},{"key":"10.1016\/j.heliyon.2024.e40995_br0180","series-title":"Proceedings of the XVth International Symposium on High Voltage Engineering, ISH","first-page":"2","article-title":"Reliability and improvements of water titration by the Karl Fischer technique","volume":"vol. 1","author":"Koch","year":"2007"},{"issue":"5","key":"10.1016\/j.heliyon.2024.e40995_br0190","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1049\/iet-smt.2018.5076","article-title":"Transformer oil diagnostic by using an optical fibre system: a review","volume":"13","author":"Razzaq","year":"2019","journal-title":"IET Sci. Meas. Technol."},{"key":"10.1016\/j.heliyon.2024.e40995_br0200","series-title":"Fiber Optic Sensors: Fundamentals and Applications","author":"Krohn","year":"2014"},{"issue":"7","key":"10.1016\/j.heliyon.2024.e40995_br0210","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.3390\/en13071789","article-title":"Review of fiber optic diagnostic techniques for power transformers","volume":"13","author":"N'cho","year":"2020","journal-title":"Energies"},{"key":"10.1016\/j.heliyon.2024.e40995_br0220","doi-asserted-by":"crossref","DOI":"10.1016\/j.snb.2020.128989","article-title":"Mems hydrogen gas sensor for in-situ monitoring of hydrogen gas in transformer oil","volume":"326","author":"Kondalkar","year":"2021","journal-title":"Sens. Actuators B, Chem."},{"issue":"21","key":"10.1016\/j.heliyon.2024.e40995_br0230","doi-asserted-by":"crossref","first-page":"7636","DOI":"10.1109\/JSEN.2016.2599644","article-title":"Low cost and pipe conformable microwave-based water-cut sensor","volume":"16","author":"Karimi","year":"2016","journal-title":"IEEE Sens. J."},{"issue":"3","key":"10.1016\/j.heliyon.2024.e40995_br0240","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1021\/acssensors.0c02219","article-title":"A highly sensitive and stable rgo: Mos2-based chemiresistive humidity sensor directly insertable to transformer insulating oil analyzed by customized electronic sensor interface","volume":"6","author":"Adib","year":"2021","journal-title":"ACS Sens."},{"issue":"9","key":"10.1016\/j.heliyon.2024.e40995_br0250","doi-asserted-by":"crossref","first-page":"3661","DOI":"10.1109\/JSEN.2018.2810827","article-title":"Interdigitated sensors: the next generation \u201csensing permittivity and conductivity of oils-unaffected by temperature\u201d","volume":"18","author":"Risos","year":"2018","journal-title":"IEEE Sens. J."},{"key":"10.1016\/j.heliyon.2024.e40995_br0260","first-page":"1","article-title":"A novel application of the cross-capacitive sensor in real-time condition monitoring of transformer oil","volume":"70","author":"Rahman","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"10.1016\/j.heliyon.2024.e40995_br0270","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.snb.2019.01.162","article-title":"Development of highly sensitive and stable humidity sensor for real-time monitoring of dissolved moisture in transformer-insulating oil","volume":"286","author":"Kondalkar","year":"2019","journal-title":"Sens. Actuators B, Chem."},{"key":"10.1016\/j.heliyon.2024.e40995_br0280","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.snb.2012.07.014","article-title":"A novel sol\u2013gel thin film porous alumina based capacitive sensor for measuring trace moisture in the range of 2.5\u201325 ppm","volume":"173","author":"Islam","year":"2012","journal-title":"Sens. Actuators B, Chem."},{"issue":"1","key":"10.1016\/j.heliyon.2024.e40995_br0290","doi-asserted-by":"crossref","first-page":"1","DOI":"10.6028\/jres.056.001","article-title":"Dielectric constant of water from 0 to 100 c","volume":"56","author":"Malmberg","year":"1956","journal-title":"J. Res. Natl. Bur. Stand."},{"issue":"20","key":"10.1016\/j.heliyon.2024.e40995_br0300","doi-asserted-by":"crossref","DOI":"10.1063\/1.4807297","article-title":"Effect of nanoparticle polarization on relative permittivity of transformer oil-based nanofluids","volume":"113","author":"Miao","year":"2013","journal-title":"J. Appl. Phys."},{"key":"10.1016\/j.heliyon.2024.e40995_br0310","doi-asserted-by":"crossref","DOI":"10.1016\/j.jappgeo.2019.103921","article-title":"The influence of temperature on the dielectric permittivity and complex electrical resistivity of porous media saturated with dnapls: a laboratory study","volume":"172","author":"Iravani","year":"2020","journal-title":"J. Appl. Geophys."},{"issue":"5","key":"10.1016\/j.heliyon.2024.e40995_br0320","doi-asserted-by":"crossref","first-page":"2530","DOI":"10.1109\/TDEI.2015.005079","article-title":"Thermal conductivity and dielectric characteristics of transformer oil filled with bn and fe 3 o 4 nanoparticles","volume":"22","author":"Du","year":"2015","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"10.1016\/j.heliyon.2024.e40995_br0330","doi-asserted-by":"crossref","first-page":"7576","DOI":"10.1109\/ACCESS.2021.3049192","article-title":"Transformer oil diagnosis based on a capacitive sensor frequency response analysis","volume":"9","author":"Guerrero","year":"2021","journal-title":"IEEE Access"},{"issue":"1","key":"10.1016\/j.heliyon.2024.e40995_br0340","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1109\/PROC.1974.9390","article-title":"A microwave instrument for the continuous monitoring of the water content of crude oil","volume":"62","author":"Castle","year":"1974","journal-title":"Proc. IEEE"},{"issue":"4","key":"10.1016\/j.heliyon.2024.e40995_br0350","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1049\/iet-smt.2019.0319","article-title":"Highly sensitive thin-film capacitive sensor for online moisture measurement in transformer oil","volume":"14","author":"Islam","year":"2020","journal-title":"IET Sci. Meas. Technol."},{"issue":"11","key":"10.1016\/j.heliyon.2024.e40995_br0360","doi-asserted-by":"crossref","first-page":"9779","DOI":"10.1109\/TIE.2019.2952817","article-title":"Condition monitoring of transformer breather using a capacitive moisture sensor","volume":"67","author":"Kumar","year":"2019","journal-title":"IEEE Trans. Ind. Electron."}],"container-title":["Heliyon"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024170260?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024170260?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,19]],"date-time":"2026-04-19T21:35:19Z","timestamp":1776634519000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405844024170260"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":36,"journal-issue":{"issue":"24","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["S2405844024170260"],"URL":"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e40995","relation":{},"ISSN":["2405-8440"],"issn-type":[{"value":"2405-8440","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Detection and continuous monitoring of moisture content in transformer oil using fractal-based capacitive sensor","name":"articletitle","label":"Article Title"},{"value":"Heliyon","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e40995","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"e40995"}}