{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T16:25:06Z","timestamp":1757780706511},"reference-count":10,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["heartlungcirc.org","mdconsult.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart, Lung and Circulation"],"published-print":{"date-parts":[[2015,1]]},"DOI":"10.1016\/j.hlc.2014.09.002","type":"journal-article","created":{"date-parts":[[2014,9,16]],"date-time":"2014-09-16T06:08:56Z","timestamp":1410847736000},"page":"e14-e17","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["Paradoxical Cardiac and Cerebral Arterial Gas Embolus During Percutaneous Lead Extraction in a Patient with a Patent Foramen Ovale"],"prefix":"10.1016","volume":"24","author":[{"given":"Clare","family":"Arnott","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keith","family":"Kelly","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Darren","family":"Wolfers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregory","family":"Cranney","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Giles","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.hlc.2014.09.002_bib0005","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/S0002-8703(03)00188-1","article-title":"Endocardial pacemaker or defibrillator leads with infected vegetations: a single-center experience and consequences of transvenous extraction","volume":"146","author":"Meier-Ewert","year":"2003","journal-title":"Am Heart J"},{"key":"10.1016\/j.hlc.2014.09.002_bib0010","doi-asserted-by":"crossref","first-page":"2699","DOI":"10.1111\/j.1540-8159.1998.tb00053.x","article-title":"A complication of pacemaker lead extraction: paradoxical embolism of a lead fragment in a leg artery","volume":"21","author":"Dieuzaide","year":"1998","journal-title":"Pacing Clin Electrophysiol"},{"issue":"3","key":"10.1016\/j.hlc.2014.09.002_bib0015","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1016\/S0003-4975(99)01406-X","article-title":"Septic paradoxical embolus through a patent foramen ovale after pacemaker implantation","volume":"69","author":"Allie","year":"2000","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.hlc.2014.09.002_bib0020","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1161\/01.CIR.0000027819.19722.EE","article-title":"Percutaneous transcatheter closure of patent foramen ovale in patients with paradoxical embolism","volume":"106","author":"Martin","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.hlc.2014.09.002_bib0025","series-title":"Interventional procedures for structural heart disease","author":"Lasala","year":"2014"},{"key":"10.1016\/j.hlc.2014.09.002_bib0030","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1111\/j.1365-2044.2004.04111.x","article-title":"Paradoxical embolism through a patent foramen ovale: an unexpected complication of tracheal extubation","volume":"60","author":"Turley","year":"2005","journal-title":"Anaesthesia"},{"key":"10.1016\/j.hlc.2014.09.002_bib0035","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1038\/ncpcardio0681","article-title":"Successful removal of a paradoxical coronary embolus using an aspiration catheter","volume":"3","author":"Wilson","year":"2006","journal-title":"Nature Clinical Practice Cardiovascular Medicine"},{"key":"10.1016\/j.hlc.2014.09.002_bib0040","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1046\/j.1540-8167.2004.04627.x","article-title":"Lead-induced venous thrombosis: consequences?","volume":"15","author":"Wilkoff","year":"2004","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hlc.2014.09.002_bib0045","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1161\/CIRCULATIONAHA.110.976449","article-title":"Safety of percutaneous left atrial appendage closure: results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF (PROTECT AF) clinical trial and the Continued Access Registry","volume":"123","author":"Reddy","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.hlc.2014.09.002_bib0050","first-page":"3671","article-title":"The WATCHMAN Left atrial appendage closure device for atrial fibrillation","volume":"60","author":"M\u00f6bius-Winkler","year":"2012","journal-title":"J Vis Exp"}],"container-title":["Heart, Lung and Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S144395061400688X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S144395061400688X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,29]],"date-time":"2018-09-29T15:53:32Z","timestamp":1538236412000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S144395061400688X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015,1]]}},"alternative-id":["S144395061400688X"],"URL":"https:\/\/doi.org\/10.1016\/j.hlc.2014.09.002","relation":{},"ISSN":["1443-9506"],"issn-type":[{"value":"1443-9506","type":"print"}],"subject":[],"published":{"date-parts":[[2015,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Paradoxical Cardiac and Cerebral Arterial Gas Embolus During Percutaneous Lead Extraction in a Patient with a Patent Foramen Ovale","name":"articletitle","label":"Article Title"},{"value":"Heart, Lung and Circulation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hlc.2014.09.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"Crown copyright \u00a9 2014 Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}