{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T23:27:16Z","timestamp":1768346836231,"version":"3.49.0"},"reference-count":18,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2017,11,1]],"date-time":"2017-11-01T00:00:00Z","timestamp":1509494400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["heartlungcirc.org","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart, Lung and Circulation"],"published-print":{"date-parts":[[2017,11]]},"DOI":"10.1016\/j.hlc.2017.03.157","type":"journal-article","created":{"date-parts":[[2017,4,20]],"date-time":"2017-04-20T21:17:38Z","timestamp":1492723058000},"page":"e82-e85","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["Acute Structural Failure of the Trifecta Aortic Valve Bioprosthesis"],"prefix":"10.1016","volume":"26","author":[{"given":"Michael Z.L.","family":"Zhu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark A.","family":"Newman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pragnesh","family":"Joshi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jurgen","family":"Passage","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.hlc.2017.03.157_bib0005","series-title":"The Trifecta valve: invitro hydrodynamic and durability comparisons of aortic bioprostheses","author":"St Jude Medical Inc","year":"2010"},{"key":"10.1016\/j.hlc.2017.03.157_bib0010","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1016\/j.jtcvs.2012.12.087","article-title":"The St Jude Medical Trifecta aortic pericardial valve: results from a global, multicenter, prospective clinical study","volume":"147","author":"Bavaria","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0015","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1093\/ejcts\/ezv070","article-title":"The TRIBECA study: (TRI)fecta (B)ioprosthesis (E)valuation versus (C)arpentier Magna-Ease in (A)ortic position","volume":"49","author":"Colli","year":"2016","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0020","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1093\/ejcts\/ezv411","article-title":"Early haemodynamic performance of a latest generation supra-annular aortic bioprosthesis: experience from a large single-centre series","volume":"49","author":"Deutsch","year":"2016","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0025","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/j.jtcvs.2016.09.089","article-title":"Midterm, multicenter clinical and hemodynamic results for the Trifecta aortic pericardial valve","volume":"153","author":"Goldman","year":"2017","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0030","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1093\/ejcts\/ezv211","article-title":"Three-year haemodynamic performance of the St Jude Trifecta bioprosthesis","volume":"49","author":"Ruggieri","year":"2016","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0035","doi-asserted-by":"crossref","first-page":"e133","DOI":"10.1016\/j.jtcvs.2014.03.018","article-title":"Early failures of Trifecta aortic bioprosthesis","volume":"148","author":"Campisi","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0040","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1111\/jocs.12778","article-title":"Early Failure of Trifecta Bioprosthesis in the Aortic Position","volume":"31","author":"Yoshida","year":"2016","journal-title":"J Card Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0045","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1093\/icvts\/ivu384","article-title":"Leaflet tear in a Trifecta aortic bioprosthesis 34 months after implantation","volume":"20","author":"Pinon","year":"2015","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0050","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.1016\/j.jtcvs.2013.05.045","article-title":"The new St Jude Trifecta versus Carpentier-Edwards Perimount Magna and Magna Ease aortic bioprosthesis: is there a hemodynamic superiority","volume":"147","author":"Wendt","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0055","unstructured":"St. Jude Medical. Long Term Follow Up Study of the St. Jude Medical Trifecta Valve. In: clinicaltrials.gov [Internet]. Bethesda (MD): National Library of Medicine (US). 2000-[cited 2016 Aug 31]. Available from: https:\/\/clinicaltrials.gov\/ct2\/show\/NCT01593917 NLM Identifier:NCT01593917."},{"key":"10.1016\/j.hlc.2017.03.157_bib0060","unstructured":"St. Jude Medical. Trifecta durability study. In: clinicaltrials.gov [Internet]. Bethesda (MD): National Library of Medicine (US). 2000-[cited 2016 Aug 31]. Available from: https:\/\/clinicaltrials.gov\/ct2\/show\/NCT01256710 NLM Identifier:NCT01256710."},{"key":"10.1016\/j.hlc.2017.03.157_bib0065","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1161\/01.CIR.76.3.618","article-title":"Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses: emphasis on progressive structural deterioration","volume":"76","author":"Schoen","year":"1987","journal-title":"Circulation"},{"key":"10.1016\/j.hlc.2017.03.157_bib0070","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/S0022-5223(19)36249-X","article-title":"Primary tissue failure in pericardial heart valves","volume":"94","author":"Wheatley","year":"1987","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0075","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/0002-9149(89)91099-0","article-title":"Mode of failure of the Hancock pericardial valve xenograft","volume":"63","author":"Thiene","year":"1989","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.hlc.2017.03.157_bib0080","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1016\/S0022-5223(19)37054-0","article-title":"Patterns of failure in Ionescu-Shiley bovine pericardial bioprosthetic valves","volume":"93","author":"Walley","year":"1987","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0085","doi-asserted-by":"crossref","first-page":"1621","DOI":"10.1016\/j.athoracsur.2011.06.092","article-title":"Modes of failure in explanted mitroflow pericardial valves","volume":"92","author":"Butany","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.hlc.2017.03.157_bib0090","doi-asserted-by":"crossref","first-page":"2012","DOI":"10.1161\/CIRCULATIONAHA.114.010400","article-title":"Early structural valve deterioration of Mitroflow aortic bioprosthesis: mode, incidence, and impact on outcome in a large cohort of patients","volume":"130","author":"Senage","year":"2014","journal-title":"Circulation"}],"container-title":["Heart, Lung and Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1443950617303207?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1443950617303207?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,10,6]],"date-time":"2020-10-06T00:42:05Z","timestamp":1601944925000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1443950617303207"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11]]},"references-count":18,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2017,11]]}},"alternative-id":["S1443950617303207"],"URL":"https:\/\/doi.org\/10.1016\/j.hlc.2017.03.157","relation":{},"ISSN":["1443-9506"],"issn-type":[{"value":"1443-9506","type":"print"}],"subject":[],"published":{"date-parts":[[2017,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Acute Structural Failure of the Trifecta Aortic Valve Bioprosthesis","name":"articletitle","label":"Article Title"},{"value":"Heart, Lung and Circulation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hlc.2017.03.157","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Crown Copyright \u00a9 2017 Published by Elsevier B.V. on behalf of Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.","name":"copyright","label":"Copyright"}]}}