{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T15:42:19Z","timestamp":1790264539551,"version":"4.1.0"},"reference-count":21,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"name":"Australasian Society of Cardiac and Thoracic Surgeons"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartlungcirc.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart, Lung and Circulation"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1016\/j.hlc.2019.01.009","type":"journal-article","created":{"date-parts":[[2019,2,2]],"date-time":"2019-02-02T16:19:10Z","timestamp":1549124350000},"page":"295-300","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Early Gastrointestinal Complications From Ventricular Assist Devices is Increased by Non-Pulsatile Flow"],"prefix":"10.1016","volume":"29","author":[{"given":"Juliana","family":"van der Merwe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eldho","family":"Paul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Franklin L.","family":"Rosenfeldt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hlc.2019.01.009_bib0005","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1001\/jama.287.5.628","article-title":"Medical management of advanced heart failure","volume":"287","author":"Nohria","year":"2002","journal-title":"JAMA"},{"key":"10.1016\/j.hlc.2019.01.009_bib0010","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1007\/s12265-009-9092-y","article-title":"Physiological and pathological changes in patients with continuous-flow ventricular assist devices","volume":"2","author":"John","year":"2009","journal-title":"J Cardiovasc Transl Res"},{"key":"10.1016\/j.hlc.2019.01.009_bib0015","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.hlc.2013.07.016","article-title":"Effect of Haemodynamic Changes on Epithelium-related Intestinal Injury in Off-pump Coronary Surgery","volume":"23","author":"Andrasi","year":"2014","journal-title":"Heart Lung Circ"},{"key":"10.1016\/j.hlc.2019.01.009_bib0020","doi-asserted-by":"crossref","first-page":"55","DOI":"10.7326\/0003-4819-105-1-54","article-title":"Cessation of recurrent bleeding from gastrointestinal angiodysplasias after aortic valve replacement","volume":"105","author":"Cappell","year":"1986","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.hlc.2019.01.009_bib0025","doi-asserted-by":"crossref","first-page":"91","DOI":"10.4037\/NCI.0b013e31824124d0","article-title":"Anticoagulation and bleeding in patients with ventricular assist devices","volume":"23","author":"Kurien","year":"2012","journal-title":"AACN Adv Crit Care"},{"issue":"3","key":"10.1016\/j.hlc.2019.01.009_bib0030","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1161\/CIRCHEARTFAILURE.112.000206","article-title":"Pulsatility and the risk of nonsurgical bleeding in patients supported with the continuous-flow left ventricular assist device HeartMate II","volume":"6","author":"Wever-Pinzon","year":"2013","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.hlc.2019.01.009_bib0035","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.healun.2003.10.018","article-title":"Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device","volume":"24","author":"Letsou","year":"2005","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.hlc.2019.01.009_bib0040","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1056\/NEJMoa022831","article-title":"Acquired von Willebrand syndrome in aortic stenosis","volume":"349","author":"Vincentelli","year":"2003","journal-title":"N Engl J Med"},{"issue":"15","key":"10.1016\/j.hlc.2019.01.009_bib0045","doi-asserted-by":"crossref","first-page":"1821","DOI":"10.1001\/archinte.163.15.1821","article-title":"Increased prevalence of aortic stenosis in patients with arteriovenous malformations of the gastrointestinal tract in Heyde syndrome","volume":"163","author":"Batur","year":"2003","journal-title":"Arch Intern Med"},{"issue":"2","key":"10.1016\/j.hlc.2019.01.009_bib0050","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1161\/CIRCULATIONAHA.115.019692","article-title":"Elevated angiopoietin-2 level in patients with continuous-flow left ventricular assist devices leads to altered angiogenesis and is associated with higher nonsurgical bleeding","volume":"134","author":"Tabit","year":"2016","journal-title":"Circulation"},{"key":"10.1016\/j.hlc.2019.01.009_bib0055","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1093\/icvts\/ivs297","article-title":"What is the optimal anticoagulation in patients with a left ventricular assist device?","volume":"15","author":"Rossi","year":"2012","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"10.1016\/j.hlc.2019.01.009_bib0060","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1016\/j.athoracsur.2009.06.095","article-title":"Activation of endothelial and coagulation systems in left ventricular assist device recipients","volume":"88","author":"John","year":"2009","journal-title":"Ann Thorac Surg"},{"issue":"Suppl 1","key":"10.1016\/j.hlc.2019.01.009_bib0065","first-page":"1189","article-title":"Treatment of thrombus formation associated with the MicroMed DeBakey VAD using recombinant tissue plasminogen activator","volume":"106","author":"Rothenburger","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.hlc.2019.01.009_bib0070","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.healun.2013.07.020","article-title":"Gastrointestinal bleeding and subsequent risk of thromboembolic events during support with a left ventricular assist device","volume":"33","author":"Stulak","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.hlc.2019.01.009_bib0075","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1007\/s001340050328","article-title":"Comparison of commonly used clinical indicators of hypovolaemia with gastrointestinal tonometry","volume":"23","author":"Hamilton-Davies","year":"1997","journal-title":"Intensive Care Med"},{"key":"10.1016\/j.hlc.2019.01.009_bib0080","first-page":"1136","article-title":"A model of countercurrent shunting of oxygen in the intestinal villus","volume":"262","author":"Shepherd","year":"1992","journal-title":"Am J Physiol"},{"key":"10.1016\/j.hlc.2019.01.009_bib0085","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1016\/S1010-7940(03)00167-2","article-title":"A prospective randomized study to evaluate splanchnic hypoxia during beating-heart and conventional coronary revascularization","volume":"23","author":"Velissaris","year":"2003","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.hlc.2019.01.009_bib0090","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/S0003-4975(10)64193-8","article-title":"Depression of pulmonary metabolic function by cardiopulmonary bypass procedures increases levels of circulating norepinephrine","volume":"38","author":"Pitt","year":"1984","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.hlc.2019.01.009_bib0095","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.ejcts.2007.03.047","article-title":"Plasma levels and vascular effects of vasopressin in patients undergoing coronary artery bypass grafting","volume":"32","author":"Novella","year":"2007","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.hlc.2019.01.009_bib0100","first-page":"150","article-title":"Gastrointestinal consequences of left ventricular assist device placement","volume":"42","author":"El-Amir","year":"1996","journal-title":"ASAIO J"},{"issue":"7","key":"10.1016\/j.hlc.2019.01.009_bib0105","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1016\/j.healun.2016.05.019","article-title":"Evaluation of von Willebrand factor with a fully magnetically levitated centrifugal continuous-flow left ventricular assist device in advanced heart failure","volume":"35","author":"Netuka","year":"2016","journal-title":"J Heart Lung Transplant"}],"container-title":["Heart, Lung and Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1443950619300447?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1443950619300447?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,25]],"date-time":"2025-10-25T18:00:21Z","timestamp":1761415221000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1443950619300447"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["S1443950619300447"],"URL":"https:\/\/doi.org\/10.1016\/j.hlc.2019.01.009","relation":{},"ISSN":["1443-9506"],"issn-type":[{"value":"1443-9506","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Early Gastrointestinal Complications From Ventricular Assist Devices is Increased by Non-Pulsatile Flow","name":"articletitle","label":"Article Title"},{"value":"Heart, Lung and Circulation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hlc.2019.01.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Published by Elsevier B.V. on behalf of Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ).","name":"copyright","label":"Copyright"}]}}