{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T10:04:56Z","timestamp":1789034696978,"version":"build-2803163510"},"reference-count":16,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,9,29]],"date-time":"2021-09-29T00:00:00Z","timestamp":1632873600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["heartrhythmopen.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm O2"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1016\/j.hroo.2021.09.008","type":"journal-article","created":{"date-parts":[[2021,10,2]],"date-time":"2021-10-02T06:40:52Z","timestamp":1633156852000},"page":"543-559","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"special_numbering":"PA","title":["Continuous ECG monitoring versus mobile telemetry: A comparison of arrhythmia diagnostics in human- versus algorithmic-dependent systems"],"prefix":"10.1016","volume":"2","author":[{"given":"Mark E.","family":"Willcox","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven J.","family":"Compton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gust H.","family":"Bardy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hroo.2021.09.008_bib1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12872-016-0210-x","article-title":"Incidence and timing of potentially high-risk arrhythmias detected through long term continuous ambulatory electrocardiographic monitoring","volume":"16","author":"Solomon","year":"2016","journal-title":"BMC Cardiovasc Disord"},{"key":"10.1016\/j.hroo.2021.09.008_bib2","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1001\/archinte.1990.00390170103022","article-title":"The duration of Holter monitoring in patients with syncope. Is 24 hours enough?","volume":"150","author":"Bass","year":"1990","journal-title":"Arch Intern Med"},{"key":"10.1016\/j.hroo.2021.09.008_bib3","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1016\/j.amjcard.2004.12.015","article-title":"First experience with a Mobile Cardiac Outpatient Telemetry (MCOT) system for the diagnosis and management of cardiac arrhythmia","volume":"95","author":"Joshi","year":"2005","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.hroo.2021.09.008_bib4","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.ahj.2016.11.006","article-title":"Comparison of diagnostic value using a small, single channel, P-wave centric sternal ECG monitoring patch with a standard 3-lead Holter system over 24 hours","volume":"185","author":"Smith","year":"2017","journal-title":"Am Heart J"},{"key":"10.1016\/j.hroo.2021.09.008_bib5","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.ahj.2018.03.022","article-title":"Comparison of 2 ambulatory patch ECG monitors: the benefit of the P-wave and signal clarity","volume":"203","author":"Rho","year":"2018","journal-title":"Am Heart J"},{"key":"10.1016\/j.hroo.2021.09.008_bib6","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/j.hrthm.2020.02.015","article-title":"Deep learning for comprehensive ECG annotation","volume":"17","author":"Teplitzky","year":"2020","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2021.09.008_bib7","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/j.jacc.2015.05.018","article-title":"Excessive atrial ectopy and short atrial runs increase the risk of stroke beyond incident atrial fibrillation","volume":"66","author":"Larsen","year":"2015","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hroo.2021.09.008_bib8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.amjmed.2013.10.003","article-title":"Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring","volume":"127","author":"Barrett","year":"2014","journal-title":"Am J Med"},{"key":"10.1016\/j.hroo.2021.09.008_bib9","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1080\/02813432.2019.1684429","article-title":"Erroneous computer-based interpretations of atrial fibrillation and atrial flutter in a Swedish primary health care setting","volume":"37","author":"Lindow","year":"2019","journal-title":"Scand J Prim Health Care"},{"key":"10.1016\/j.hroo.2021.09.008_bib10","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.amjmed.2004.06.024","article-title":"Misdiagnosis of atrial fibrillation and its clinical consequences","volume":"117","author":"Bogun","year":"2004","journal-title":"Am J Med"},{"key":"10.1016\/j.hroo.2021.09.008_bib11","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1197\/jamia.M1279","article-title":"Computer decision support as a source of interpretation error: the case of electrocardiograms","volume":"10","author":"Tsai","year":"2003","journal-title":"J Am Med Inform Assoc"},{"key":"10.1016\/j.hroo.2021.09.008_bib12","unstructured":"Medical electrical equipment \u2013 Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems. IEC 60601-2-47 International Standard, Edition 2.0, 2012-02. https:\/\/webstore.iec.ch\/publication\/2666."},{"key":"10.1016\/j.hroo.2021.09.008_bib13","unstructured":"Association for the Advancement of Medical Instrumentation. American National Standard: ANSI\/AAMI EC57:2012. Testing and reporting performance results of cardiac rhythm and ST segment algorithms. https:\/\/webstore.ansi.org\/standards\/aami\/ansiaamiec572012ec57?_ga=2.212378327.2125740199.1634681486-720156544.1634681486."},{"key":"10.1016\/j.hroo.2021.09.008_bib14","unstructured":"IEC 60601-2-47 International Standard, Edition 2.0, 2012-02._Databases."},{"key":"10.1016\/j.hroo.2021.09.008_bib15","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1161\/STROKEAHA.112.679100","article-title":"Pilot randomized trial of outpatient cardiac monitoring after cryptogenic stroke","volume":"44","author":"Kamel","year":"2013","journal-title":"Stroke"},{"key":"10.1016\/j.hroo.2021.09.008_bib16","doi-asserted-by":"crossref","first-page":"2069","DOI":"10.1016\/j.jstrokecerebrovasdis.2015.05.031","article-title":"Low yield of mobile cardiac outpatient telemetry after cryptogenic stroke in patients with extensive cardiac imaging","volume":"24","author":"Kalani","year":"2015","journal-title":"J Stroke Cerebrovasc Dis"}],"container-title":["Heart Rhythm O2"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666501821001902?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666501821001902?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:26:12Z","timestamp":1762993572000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666501821001902"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":16,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["S2666501821001902"],"URL":"https:\/\/doi.org\/10.1016\/j.hroo.2021.09.008","relation":{},"ISSN":["2666-5018"],"issn-type":[{"value":"2666-5018","type":"print"}],"subject":[],"published":{"date-parts":[[2021,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Continuous ECG monitoring versus mobile telemetry: A comparison of arrhythmia diagnostics in human- versus algorithmic-dependent systems","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm O2","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hroo.2021.09.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Heart Rhythm Society. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}