{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T21:15:29Z","timestamp":1790630129152,"version":"4.1.0"},"reference-count":32,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,4,24]],"date-time":"2024-04-24T00:00:00Z","timestamp":1713916800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["heartrhythmopen.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm O2"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1016\/j.hroo.2024.04.011","type":"journal-article","created":{"date-parts":[[2024,4,26]],"date-time":"2024-04-26T15:57:44Z","timestamp":1714147064000},"page":"374-384","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":24,"title":["Posterior wall ablation for persistent atrial fibrillation: Very-high-power short-duration versus standard-power radiofrequency ablation"],"prefix":"10.1016","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1924-6548","authenticated-orcid":false,"given":"Paolo","family":"Compagnucci","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Volpato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Cipolletta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Quintino","family":"Parisi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yari","family":"Valeri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Campanelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonardo","family":"D\u2019Angelo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Ciliberti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulia","family":"Stronati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Carboni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Giovagnoni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federico","family":"Guerra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Natale","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michela","family":"Casella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Dello Russo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hroo.2024.04.011_bib1","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1093\/eurheartj\/ehaa612","volume":"42","author":"Hindricks","year":"2021","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hroo.2024.04.011_bib2","doi-asserted-by":"crossref","first-page":"1812","DOI":"10.1056\/NEJMoa1408288","article-title":"Approaches to catheter ablation for persistent atrial fibrillation","volume":"372","author":"Verma","year":"2015","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hroo.2024.04.011_bib3","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1093\/europace\/euab161","article-title":"Targeting non-pulmonary vein triggers in persistent atrial fibrillation: results from a prospective, multicentre, observational registry","volume":"23","author":"Della Rocca","year":"2021","journal-title":"Europace"},{"key":"10.1016\/j.hroo.2024.04.011_bib4","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.hrthm.2015.10.023","article-title":"Prevalence and distribution of focal triggers in persistent and long-standing persistent atrial fibrillation","volume":"13","author":"Santangeli","year":"2016","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2024.04.011_bib5","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.jacep.2019.04.009","article-title":"Pulmonary vein isolation with very high power, short duration, temperature-controlled lesions: the QDOT-FAST trial","volume":"5","author":"Reddy","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib6","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/j.jacep.2022.10.019","article-title":"Very high-power short-duration, temperature-controlled radiofrequency ablation in paroxysmal atrial fibrillation: the prospective multicenter Q-FFICIENCY trial","volume":"9","author":"Osorio","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib7","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1093\/europace\/euac243","article-title":"Very high-power short-duration ablation for pulmonary vein isolation utilizing a very-close protocol-the FAST AND FURIOUS PVI study","volume":"25","author":"Heeger","year":"2023","journal-title":"Europace"},{"key":"10.1016\/j.hroo.2024.04.011_bib8","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1111\/jce.15908","article-title":"Microelectrode voltage mapping for substrate assessment in catheter ablation of ventricular tachycardia: a dual-center experience","volume":"34","author":"Dello Russo","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib9","doi-asserted-by":"crossref","first-page":"e006576","DOI":"10.1161\/CIRCEP.118.006576","article-title":"Use of ablation index-guided ablation results in high rates of durable pulmonary vein isolation and freedom from arrhythmia in persistent atrial fibrillation patients: the PRAISE study results","volume":"11","author":"Hussein","year":"2018","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib10","doi-asserted-by":"crossref","first-page":"1802","DOI":"10.3390\/jcm11071802","article-title":"Ablation index predicts successful ablation of focal atrial tachycardia: results of a multicenter study","volume":"11","author":"Compagnucci","year":"2022","journal-title":"J Clin Med"},{"key":"10.1016\/j.hroo.2024.04.011_bib11","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1007\/s10840-020-00781-3","article-title":"Recent advances in three-dimensional electroanatomical mapping guidance for the ablation of complex atrial and ventricular arrhythmias","volume":"61","author":"Compagnucci","year":"2021","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib12","doi-asserted-by":"crossref","first-page":"1541","DOI":"10.1016\/j.jacep.2018.08.015","article-title":"Validating left atrial low voltage areas during atrial fibrillation and atrial flutter using multielectrode automated electroanatomic mapping","volume":"4","author":"Rodr\u00edguez-Ma\u00f1ero","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib13","doi-asserted-by":"crossref","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","article-title":"2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"14","author":"Calkins","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2024.04.011_bib14","unstructured":"Glashan CA, Beukers HKC, Tofig BJ, et\u00a0al. Mini-, micro-, and conventional electrodes: an in\u00a0vivo electrophysiology and ex\u00a0vivo histology head-to-head comparison."},{"key":"10.1016\/j.hroo.2024.04.011_bib15","doi-asserted-by":"crossref","DOI":"10.1007\/s10840-023-01705-7","article-title":"Technological advances in ventricular tachycardia catheter ablation: the relentless quest for novel solutions to old problems","author":"Compagnucci","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib16","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/j.hrthm.2021.12.006","article-title":"High-resolution parahisian mapping and ablation using microelectrode embedded ablation catheters","volume":"19","author":"Berte","year":"2022","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2024.04.011_bib17","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.jacep.2015.09.001","article-title":"Substrate mapping for ventricular tachycardia: assumptions and misconceptions","volume":"1","author":"Josephson","year":"2015","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib18","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","article-title":"Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial","volume":"64","author":"Natale","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib19","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.jacep.2017.11.018","article-title":"High-power and short-duration ablation for pulmonary vein isolation: biophysical characterization","volume":"4","author":"Leshem","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib20","doi-asserted-by":"crossref","first-page":"e009899","DOI":"10.1161\/CIRCEP.121.009899","article-title":"Comparison of in\u00a0vivo tissue temperature profile and lesion geometry for radiofrequency ablation with high power-short duration and moderate power-moderate duration: effects of thermal latency and contact force on lesion formation","volume":"14","author":"Nakagawa","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib21","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1007\/s10840-023-01612-x","article-title":"High-power short-duration catheter ablation of atrial fibrillation: is it really a new era? Comparison between new and old radiofrequency contact force\u2013sensing catheters","volume":"67","author":"Dello Russo","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib22","first-page":"100847","article-title":"Very high-power short-duration temperature-controlled ablation versus conventional power-controlled ablation for pulmonary vein isolation: the fast and furious\u2013AF study","volume":"35","author":"Tilz","year":"2021","journal-title":"Int J Cardiol Heart Vasc"},{"key":"10.1016\/j.hroo.2024.04.011_bib23","doi-asserted-by":"crossref","first-page":"1911","DOI":"10.1007\/s10840-023-01520-0","article-title":"One-year outcomes in patients undergoing very high-power short-duration ablation for atrial fibrillation","volume":"66","author":"Solimene","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib24","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.jacep.2023.09.004","article-title":"EsophAguS Deviation During RadiofrequencY Ablation of Atrial Fibrillation: the EASY AF trial","volume":"10","author":"Weiss","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib25","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1007\/s10840-021-00960-w","article-title":"Active esophageal cooling for the prevention of thermal injury during atrial fibrillation ablation: a randomized controlled pilot study","volume":"63","author":"Tschabrunn","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib26","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1111\/jce.14480","article-title":"Clinical outcomes of adjunctive posterior wall isolation in persistent atrial fibrillation: a meta-analysis","volume":"31","author":"Salih","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib27","doi-asserted-by":"crossref","first-page":"2567","DOI":"10.1111\/jce.15164","article-title":"The role of posterior wall isolation in catheter ablation of persistent atrial fibrillation","volume":"32","author":"Clarke","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib28","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1001\/jama.2022.23722","article-title":"Effect of catheter ablation using pulmonary vein isolation with vs without posterior left atrial wall isolation on atrial arrhythmia recurrence in patients with persistent atrial fibrillation: the CAPLA randomized clinical trial","volume":"329","author":"Kistler","year":"2023","journal-title":"JAMA"},{"key":"10.1016\/j.hroo.2024.04.011_bib29","doi-asserted-by":"crossref","DOI":"10.1056\/EVIDoa2200141","article-title":"Low-voltage myocardium-guided ablation trial of persistent atrial fibrillation","volume":"1","author":"Huo","year":"2022","journal-title":"NEJM Evid"},{"key":"10.1016\/j.hroo.2024.04.011_bib30","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.hrthm.2015.08.019","article-title":"Proven isolation of the pulmonary vein antrum with or without left atrial posterior wall isolation in patients with persistent atrial fibrillation","volume":"13","author":"Bai","year":"2016","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2024.04.011_bib31","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1111\/jce.13885","article-title":"Roof-dependent atrial flutter with an epicardial component: role of the septopulmonary bundle","volume":"30","author":"Garcia","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hroo.2024.04.011_bib32","doi-asserted-by":"crossref","first-page":"2107","DOI":"10.1111\/jce.15151","article-title":"Stepwise endo-\/epicardial catheter ablation for atrial fibrillation: the Mediterranea approach","volume":"32","author":"De Martino","year":"2021","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Heart Rhythm O2"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666501824001065?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666501824001065?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,6,20]],"date-time":"2024-06-20T08:18:38Z","timestamp":1718871518000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666501824001065"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6]]},"references-count":32,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["S2666501824001065"],"URL":"https:\/\/doi.org\/10.1016\/j.hroo.2024.04.011","relation":{},"ISSN":["2666-5018"],"issn-type":[{"value":"2666-5018","type":"print"}],"subject":[],"published":{"date-parts":[[2024,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Posterior wall ablation for persistent atrial fibrillation: Very-high-power short-duration versus standard-power radiofrequency ablation","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm O2","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hroo.2024.04.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Heart Rhythm Society. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}