{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T16:23:53Z","timestamp":1780503833530,"version":"3.54.1"},"reference-count":12,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T00:00:00Z","timestamp":1767657600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004331","name":"Johnson and Johnson","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004331","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmopen.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm O2"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1016\/j.hroo.2025.11.029","type":"journal-article","created":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T00:33:22Z","timestamp":1767918802000},"page":"443-453","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["First-in-human experience for cardiac arrhythmia mapping using a novel ultra-high\u2013density globe-shaped catheter from the multicenter COSMOS study"],"prefix":"10.1016","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6864-3999","authenticated-orcid":false,"given":"Ante","family":"Anic","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Massimo","family":"Grimaldi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom","family":"De Potter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlo","family":"de Asmundis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gian Battista","family":"Chierchia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federico","family":"Quadrini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"di Monaco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toni","family":"Bre\u0161kovi\u0107","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moussa","family":"Mansour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Nakagawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandre","family":"Almorad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hroo.2025.11.029_bib1","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.acvd.2017.04.005","article-title":"A comparison between multipolar mapping and conventional mapping of atrial tachycardias in the context of atrial fibrillation ablation","volume":"111","author":"Bun","year":"2018","journal-title":"Arch Cardiovasc Dis"},{"key":"10.1016\/j.hroo.2025.11.029_bib2","doi-asserted-by":"crossref","first-page":"9139","DOI":"10.1038\/s41598-022-12918-7","article-title":"The impact of ultra-high-density mapping on long-term outcome after catheter ablation of ventricular tachycardia","volume":"12","author":"Schleberger","year":"2022","journal-title":"Sci Rep"},{"key":"10.1016\/j.hroo.2025.11.029_bib3","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1111\/pace.14890","article-title":"Comparison of voltage maps using OCTARAY catheter and PENTARAY catheter","volume":"47","author":"Masuda","year":"2024","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2025.11.029_bib4","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1111\/jce.13867","article-title":"A novel OCTARAY multielectrode catheter for high-resolution atrial mapping: electrogram characterization and utility for mapping ablation gaps","volume":"30","author":"Sroubek","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hroo.2025.11.029_bib5","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1007\/s10840-022-01283-0","article-title":"Rhythmia zero-fluoroscopy workflow with high-power, short-duration ablation: retrospective analysis of procedural data","volume":"65","author":"Cuellar-Silva","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hroo.2025.11.029_bib6","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1007\/s10840-022-01176-2","article-title":"An early multicenter experience of the novel high-density star-shaped mapping catheter in complex arrhythmias","volume":"64","author":"Sarkozy","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hroo.2025.11.029_bib7","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1093\/europace\/euy191","article-title":"Acute safety, effectiveness, and real-world clinical usage of ultra-high density mapping for ablation of cardiac arrhythmias: results of the TRUE HD study","volume":"21","author":"Hindricks","year":"2019","journal-title":"Europace"},{"key":"10.1016\/j.hroo.2025.11.029_bib8","doi-asserted-by":"crossref","first-page":"1563","DOI":"10.1007\/s10840-023-01568-y","article-title":"Safety and feasibility of a novel multielectrode array catheter in mapping atrial and ventricular arrhythmias with high density: results from the multicenter OPTIMUM study","volume":"66","author":"Vijgen","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hroo.2025.11.029_bib9","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1016\/j.hrthm.2024.03.002","article-title":"Effect of reference electrode on intracardiac electrograms: close indifferent electrode vs Wilson central terminal","volume":"21","author":"Yamamoto","year":"2024","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2025.11.029_bib10","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2023.03.1018","article-title":"Reduction of far-field potentials using close unipolar electrograms in a new ultra-high resolution catheter mapping system: evaluation in a swine atrial linear lesion model (PO-03-105)","volume":"20","author":"Sugawara","year":"2023","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2025.11.029_bib11","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2021.06.777","article-title":"Improved accuracy of complex atrial mapping using close-unipolar electrograms in a novel ultra-high resolution catheter mapping system","volume":"18","author":"Nakagawa","year":"2021","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2025.11.029_bib12","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2022.03.933","article-title":"Reduction of far-field potentials using close unipolar electrograms in a novel ultra-high resolution catheter mapping system: evaluation in a swine atrial linear lesion model","volume":"19","author":"An","year":"2022","journal-title":"Heart Rhythm"}],"container-title":["Heart Rhythm O2"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666501826000073?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666501826000073?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T12:16:19Z","timestamp":1777637779000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666501826000073"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["S2666501826000073"],"URL":"https:\/\/doi.org\/10.1016\/j.hroo.2025.11.029","relation":{},"ISSN":["2666-5018"],"issn-type":[{"value":"2666-5018","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"First-in-human experience for cardiac arrhythmia mapping using a novel ultra-high\u2013density globe-shaped catheter from the multicenter COSMOS study","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm O2","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hroo.2025.11.029","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Heart Rhythm Society. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}