{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T08:25:31Z","timestamp":1787214331231,"version":"build-2736575974"},"reference-count":29,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T00:00:00Z","timestamp":1777507200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmopen.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm O2"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.hroo.2026.04.018","type":"journal-article","created":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T23:16:00Z","timestamp":1778109360000},"page":"1498-1505","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Lead fragment characteristics and detection by radiographic imaging after heart transplant"],"prefix":"10.1016","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6845-7133","authenticated-orcid":false,"given":"Christian","family":"Bichard","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriela","family":"Narowska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward R.","family":"Horton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiya","family":"Toyoda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Derek K.","family":"Afflu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roh","family":"Yanagida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carly A.","family":"Fabrizio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacqueline","family":"Burnell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Altneu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lyana","family":"Labrada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David B.","family":"Laslett","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edmond M.","family":"Cronin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua M.","family":"Cooper","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eman A.","family":"Hamad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2329-7690","authenticated-orcid":false,"given":"Isaac R.","family":"Whitman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hroo.2026.04.018_bib1","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.hroo.2022.03.004","article-title":"Temporal trends and long-term outcomes among recipients of cardiac resynchronization therapy with defibrillator in the United States, 2011\u20132015: Insights from the National Cardiovascular Data Registry","volume":"3","author":"Darden","year":"2022","journal-title":"Heart Rhythm O2"},{"key":"10.1016\/j.hroo.2026.04.018_bib2","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.120.019655","article-title":"National trends in heart donor usage rates: are we efficiently transplanting more hearts?","volume":"10","author":"Dharmavaram","year":"2021","journal-title":"J Am Heart Assoc"},{"key":"10.1016\/j.hroo.2026.04.018_bib3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jacep.2016.06.009","article-title":"Cardiac implantable electronic device infections: added complexity and suboptimal outcomes with previously abandoned leads","volume":"3","author":"Hussein","year":"2017","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2026.04.018_bib4","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1111\/pace.13715","article-title":"To abandon or not to abandon: late consequences of pacing and ICD lead abandonment","volume":"42","author":"Jache\u0107","year":"2019","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2026.04.018_bib5","doi-asserted-by":"crossref","first-page":"2349","DOI":"10.3390\/jcm13082349","article-title":"Lead break during extraction: predisposing factors and impact on procedure complexity and outcome: analysis of 3825 procedures","volume":"13","author":"Kutarski","year":"2024","journal-title":"J Clin Med"},{"key":"10.1016\/j.hroo.2026.04.018_bib6","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.hlc.2016.06.1217","article-title":"Lead extraction for treatment of cardiac device infection: A 20-year single centre experience","volume":"26","author":"Gomes","year":"2017","journal-title":"Heart Lung Circ"},{"key":"10.1016\/j.hroo.2026.04.018_bib7","first-page":"597","article-title":"Infectious complications in patients with cardiac implantable electronic devices: risk factors, prevention, and prognosis","volume":"127","author":"Polewczyk","year":"2017","journal-title":"Pol Arch Intern Med"},{"key":"10.1016\/j.hroo.2026.04.018_bib8","doi-asserted-by":"crossref","first-page":"3021","DOI":"10.1111\/ajt.14755","article-title":"Burden and consequences of retained cardiovascular implantable electronic device lead fragments after heart transplantation","volume":"18","author":"Alvarez","year":"2018","journal-title":"Am J Transplant"},{"key":"10.1016\/j.hroo.2026.04.018_bib9","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.cardfail.2017.12.012","article-title":"Consequences of retained defibrillator and pacemaker leads after heart transplantation-an underrecognized problem","volume":"24","author":"Holzhauser","year":"2018","journal-title":"J Card Fail"},{"key":"10.1016\/j.hroo.2026.04.018_bib10","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1111\/pace.12274","article-title":"Frequency and sequelae of retained implanted cardiac device material post heart transplantation","volume":"37","author":"Martin","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2026.04.018_bib11","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1093\/icvts\/ivs100","article-title":"Three-dimensional computed tomography imaging of an implantable cardioverter-defibrillator lead fragment in the left ventricle of a heart transplant followed by successful transarterial extraction with a snare catheter","volume":"15","author":"Luehr","year":"2012","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"10.1016\/j.hroo.2026.04.018_bib12","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.ahj.2017.04.011","article-title":"Retained cardiac implantable electronic device fragments are not associated with magnetic resonance imaging safety issues, morbidity, or mortality after orthotopic heart transplant","volume":"190","author":"Austin","year":"2017","journal-title":"Am Heart J"},{"key":"10.1016\/j.hroo.2026.04.018_bib13","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1097\/01.tp.0000188953.86035.2d","article-title":"Bloodstream infections among heart transplant recipients","volume":"81","author":"Rodr\u00edguez","year":"2006","journal-title":"Transplantation"},{"key":"10.1016\/j.hroo.2026.04.018_bib14","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1007\/s15010-020-01410-x","article-title":"Complications of retained pacemaker hardware in heart transplant recipients: case series and review of the literature","volume":"48","author":"Fardman","year":"2020","journal-title":"Infection"},{"key":"10.1016\/j.hroo.2026.04.018_bib15","doi-asserted-by":"crossref","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2026.04.018_bib16","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1016\/j.hrthm.2009.05.020","article-title":"Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA)","volume":"6","author":"Wilkoff","year":"2009","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2026.04.018_bib17","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1093\/europace\/euy050","article-title":"2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS\/HRS\/LAHRS","volume":"20","author":"Bongiorni","year":"2018","journal-title":"Europace"},{"key":"10.1016\/j.hroo.2026.04.018_bib18","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1111\/j.1540-8159.2011.03273.x","article-title":"Large, single-center experience in transvenous coronary sinus lead extraction: procedural outcomes and predictors for mechanical dilatation","volume":"35","author":"di Cori","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hroo.2026.04.018_bib19","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.hrthm.2017.11.008","article-title":"Unrecognized venous injuries after cardiac implantable electronic device transvenous lead extraction","volume":"15","author":"Tarakji","year":"2018","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2026.04.018_bib20","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1111\/jce.14393","article-title":"Transvenous lead extraction after heart transplantation: how to avoid abandoned lead fragments","volume":"31","author":"Hahnel","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hroo.2026.04.018_bib21","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1016\/j.hrthm.2013.03.046","article-title":"No benefit of a dual coil over a single coil ICD lead: evidence from the sudden cardiac death in Heart Failure Trial","volume":"10","author":"Aoukar","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2026.04.018_bib22","doi-asserted-by":"crossref","DOI":"10.1002\/clc.70083","article-title":"Comparison of Single-Coil versus Dual-Coil implantable cardioverter defibrillator devices: A systematic review and meta-analysis of efficacy and extraction-related outcomes","volume":"48","author":"Tahir","year":"2025","journal-title":"Clin Cardiol"},{"key":"10.1016\/j.hroo.2026.04.018_bib23","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.116.004768","article-title":"Incidence and predictors of perioperative complications with transvenous lead extractions: real-world experience with national cardiovascular data registry","volume":"11","author":"Sood","year":"2018","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hroo.2026.04.018_bib24","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1016\/j.hrthm.2021.10.019","article-title":"Predictors of perforation during lead extraction: results of the Canadian Lead ExtrAction Risk (CLEAR) study","volume":"19","author":"Bashir","year":"2022","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hroo.2026.04.018_bib25","first-page":"e895","article-title":"2022 AHA\/ACC\/HFSA guideline for the management of heart failure: a report of the American College of Cardiology\/American Heart Association joint committee on clinical practice guidelines","volume":"145","author":"Heidenreich","year":"2022","journal-title":"Circulation"},{"key":"10.1016\/j.hroo.2026.04.018_bib26","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.mib.2013.06.013","article-title":"Bacterial biofilm development as a multicellular adaptation: antibiotic resistance and new therapeutic strategies","volume":"16","author":"de la Fuente-N\u00fa\u00f1ez","year":"2013","journal-title":"Curr Opin Microbiol"},{"key":"10.1016\/j.hroo.2026.04.018_bib27","doi-asserted-by":"crossref","first-page":"178","DOI":"10.3389\/fcimb.2014.00178","article-title":"Staphylococcus aureus biofilms: recent developments in biofilm dispersal","volume":"4","author":"Lister","year":"2014","journal-title":"Front Cell Infect Microbiol"},{"key":"10.1016\/j.hroo.2026.04.018_bib28","article-title":"Bacterial biofilm formation on biomaterials and approaches to its treatment and prevention","volume":"24","author":"Li","year":"2023","journal-title":"Int J Mol Sci"},{"key":"10.1016\/j.hroo.2026.04.018_bib29","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1001\/jamacardio.2020.7572","article-title":"Magnetic resonance imaging in patients with cardiac implantable electronic devices with abandoned leads","volume":"6","author":"Schaller","year":"2021","journal-title":"JAMA Cardiol"}],"container-title":["Heart Rhythm O2"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S266650182600200X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S266650182600200X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T08:10:41Z","timestamp":1787213441000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S266650182600200X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":29,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["S266650182600200X"],"URL":"https:\/\/doi.org\/10.1016\/j.hroo.2026.04.018","relation":{},"ISSN":["2666-5018"],"issn-type":[{"value":"2666-5018","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Lead fragment characteristics and detection by radiographic imaging after heart transplant","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm O2","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hroo.2026.04.018","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Heart Rhythm Society. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}