{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T10:15:06Z","timestamp":1760955306920},"reference-count":24,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2011,12,1]],"date-time":"2011-12-01T00:00:00Z","timestamp":1322697600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2011,12]]},"DOI":"10.1016\/j.hrthm.2011.07.031","type":"journal-article","created":{"date-parts":[[2011,8,2]],"date-time":"2011-08-02T05:29:24Z","timestamp":1312262964000},"page":"1875-1880","source":"Crossref","is-referenced-by-count":13,"title":["Luminal esophageal temperature rise and esophageal lesion formation following remote-controlled magnetic pulmonary vein isolation"],"prefix":"10.1016","volume":"8","author":[{"given":"Melanie","family":"Konstantinidou","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erik","family":"Wissner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julian K.R.","family":"Chun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Buelent","family":"Koektuerk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Metzner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roland R.","family":"Tilz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Rillig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Fuernkranz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Wohlmuth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Feifan","family":"Ouyang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karl-Heinz","family":"Kuck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2011.07.031_bib1","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1046\/j.1540-8167.2004.04083.x","article-title":"Left atrial-esophageal fistula following radiofrequency catheter ablation of atrial fibrillation","volume":"15","author":"Scanavacca","year":"2004","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib2","doi-asserted-by":"crossref","first-page":"2724","DOI":"10.1161\/01.CIR.0000131866.44650.46","article-title":"Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation","volume":"109","author":"Pappone","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2011.07.031_bib3","doi-asserted-by":"crossref","first-page":"1798","DOI":"10.1016\/j.jacc.2009.02.022","article-title":"Prevalence and causes of fatal outcome in catheter ablation of atrial fibrillation","volume":"53","author":"Cappato","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib4","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1161\/CIRCEP.109.859116","article-title":"Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation","volume":"3","author":"Cappato","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib5","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1111\/j.1540-8167.2005.00333.x","article-title":"Real-time monitoring of luminal esophageal temperature during left atrial radiofrequency catheter ablation for atrial fibrillation: observations about esophageal heating during ablation at the pulmonary vein ostia and posterior left atrium","volume":"17","author":"Perzanowski","year":"2006","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib6","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1161\/CIRCEP.107.789552","article-title":"Esophageal injury and temperature monitoring during atrial fibrillation ablation","volume":"1","author":"Singh","year":"2008","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib7","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1161\/CIRCEP.108.805366","article-title":"Limitations of esophageal temperature-monitoring to prevent esophageal injury during atrial fibrillation ablation","volume":"1","author":"Nakagawa","year":"2008","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib8","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1007\/BF03091740","article-title":"An in vivo comparison of radiofrequency cardiac lesions formed by standard and magnetically steered 4 mm tip catheters","volume":"18","author":"Thornton","year":"2010","journal-title":"Neth Heart J"},{"key":"10.1016\/j.hrthm.2011.07.031_bib9","doi-asserted-by":"crossref","first-page":"1399","DOI":"10.1111\/j.1540-8159.2008.01202.x","article-title":"Impact of remote magnetic catheter navigation on ablation fluoroscopy and procedure time","volume":"31","author":"Kim","year":"2008","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib10","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1093\/europace\/euq344","article-title":"Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study","volume":"13","author":"Arya","year":"2011","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2011.07.031_bib11","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.hrthm.2010.09.074","article-title":"Irrigated-tip magnetic catheter ablation of AF: a long-term prospective study in 130 patients","volume":"8","author":"Pappone","year":"2011","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2011.07.031_bib12","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1161\/CIRCEP.109.922930","article-title":"Fatal end of a safety algorithm for pulmonary vein isolation with use of high-intensity focused ultrasound","volume":"3","author":"Neven","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib13","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.hrthm.2011.01.022","article-title":"Esophageal temperature change and esophageal thermal lesions after pulmonary vein isolation using the novel endoscopic ablation system","volume":"8","author":"Metzner","year":"2011","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2011.07.031_bib14","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1111\/j.1540-8167.2010.01742.x","article-title":"Unexpected high incidence of esophageal injury following pulmonary vein isolation using robotic navigation","volume":"21","author":"Tilz","year":"2010","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib15","doi-asserted-by":"crossref","first-page":"1952","DOI":"10.1016\/j.jacc.2003.07.023","article-title":"Magnetic guidance system for cardiac electrophysiology: a prospective trial of safety and efficacy in humans","volume":"42","author":"Faddis","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib16","doi-asserted-by":"crossref","first-page":"2980","DOI":"10.1161\/01.CIR.0000038704.84304.6F","article-title":"Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation","volume":"106","author":"Faddis","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2011.07.031_bib17","doi-asserted-by":"crossref","first-page":"1472","DOI":"10.1161\/01.CIR.0000125126.83579.1B","article-title":"Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation","volume":"109","author":"Ernst","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2011.07.031_bib18","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1093\/eurheartj\/ehl447","article-title":"Remote-controlled catheter ablation of accessory pathways: results from the magnetic laboratory","volume":"28","author":"Chun","year":"2007","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2011.07.031_bib19","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1016\/j.jacc.2005.11.058","article-title":"Robotic magnetic navigation for atrial fibrillation ablation","volume":"47","author":"Pappone","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib20","doi-asserted-by":"crossref","first-page":"2090","DOI":"10.1161\/01.CIR.0000144459.37455.EE","article-title":"Complete isolation of left atrium surrounding the pulmonary veins: new insights from the double-Lasso technique in paroxysmal atrial fibrillation","volume":"110","author":"Ouyang","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2011.07.031_bib21","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1016\/j.jacc.2007.05.023","article-title":"Remote magnetic navigation: human experience in pulmonary vein ablation","volume":"50","author":"Di Biase","year":"2007","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib22","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1161\/CIRCEP.110.942672","article-title":"Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation","volume":"3","author":"Chun","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2011.07.031_bib23","doi-asserted-by":"crossref","first-page":"2581","DOI":"10.1378\/chest.128.4.2581","article-title":"Anatomic relationship of the esophagus and left atrium: implication for catheter ablation of atrial fibrillation","volume":"128","author":"Tsao","year":"2005","journal-title":"Chest"},{"key":"10.1016\/j.hrthm.2011.07.031_bib24","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1161\/CIRCULATIONAHA.104.509612","article-title":"Assessment of temperature, proximity, and course of the esophagus during radiofrequency ablation within the left atrium","volume":"112","author":"Cummings","year":"2005","journal-title":"Circulation"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527111008514?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527111008514?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,4,9]],"date-time":"2024-04-09T13:07:54Z","timestamp":1712668074000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527111008514"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,12]]},"references-count":24,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2011,12]]}},"alternative-id":["S1547527111008514"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2011.07.031","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2011,12]]}}}