{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T05:22:40Z","timestamp":1789708960067,"version":"4.0.1"},"reference-count":23,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T00:00:00Z","timestamp":1398902400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T00:00:00Z","timestamp":1398902400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2014,5]]},"DOI":"10.1016\/j.hrthm.2014.02.009","type":"journal-article","created":{"date-parts":[[2014,2,12]],"date-time":"2014-02-12T08:45:37Z","timestamp":1392194737000},"page":"828-835","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":46,"title":["Impact of prolonged implantable cardioverter-defibrillator arrhythmia detection times on outcomes: A meta-analysis"],"prefix":"10.1016","volume":"11","author":[{"given":"Paul A.","family":"Scott","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Silberbauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theresa A.","family":"McDonagh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francis D.","family":"Murgatroyd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2014.02.009_bib1","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1056\/NEJMoa0706719","article-title":"Quality of life with defibrillator therapy or amiodarone in heart failure","volume":"359","author":"Mark","year":"2008","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2014.02.009_bib2","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1056\/NEJMoa071098","article-title":"Prognostic importance of defibrillator shocks in patients with heart failure","volume":"359","author":"Poole","year":"2008","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2014.02.009_bib3","first-page":"859","article-title":"Implantable cardioverter-defibrillator shocks: epidemiology, outcomes, and therapeutic approaches","volume":"173","author":"Borne","year":"2013","journal-title":"JAMA"},{"key":"10.1016\/j.hrthm.2014.02.009_bib4","doi-asserted-by":"crossref","first-page":"2275","DOI":"10.1056\/NEJMoa1211107","article-title":"Reduction in inappropriate therapy and mortality through ICD programming","volume":"367","author":"Moss","year":"2012","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2014.02.009_bib5","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1161\/CIRCULATIONAHA.112.000542","article-title":"Optimal programming of implantable cardiac-defibrillators","volume":"128","author":"Madhavan","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2014.02.009_bib6","doi-asserted-by":"crossref","first-page":"d5928","DOI":"10.1136\/bmj.d5928","article-title":"The Cochrane Collaboration\u2019s tool for assessing risk of bias in randomised trials","volume":"343","author":"Higgins","year":"2011","journal-title":"BMJ"},{"key":"10.1016\/j.hrthm.2014.02.009_bib7","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/0197-2456(86)90046-2","article-title":"Meta-analysis in clinical trials","volume":"7","author":"DerSimonian","year":"1986","journal-title":"Control Clin Trials"},{"key":"10.1016\/j.hrthm.2014.02.009_bib8","doi-asserted-by":"crossref","first-page":"2758","DOI":"10.1093\/eurheartj\/ehp247","volume":"30","author":"Gasparini","year":"2009","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2014.02.009_bib9","unstructured":"Higgins JPT, Green S, editors. Cochrane Handbook for Systematic Reviews of Interventions, version 5.1.0 [Updated March 2011]. The Cochrane Collaboration, 2011. Available from http:\/\/www.Cochrane-handbook.Org."},{"key":"10.1016\/j.hrthm.2014.02.009_bib10","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","article-title":"Measuring inconsistency in meta-analyses","volume":"327","author":"Higgins","year":"2003","journal-title":"BMJ"},{"key":"10.1016\/j.hrthm.2014.02.009_bib11","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1016\/j.jacc.2008.05.011","article-title":"Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the prepare (primary prevention parameters evaluation) study","volume":"52","author":"Wilkoff","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2014.02.009_bib12","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1093\/europace\/eus028","article-title":"Long-term follow-up on high-rate cut-off programming for implantable cardioverter defibrillators in primary prevention patients with left ventricular systolic dysfunction","volume":"14","author":"Clementy","year":"2012","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2014.02.009_bib13","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/s10840-012-9735-9","article-title":"Single-chamber ICD, single-zone therapy in primary and secondary prevention patients: the simpler the better?","volume":"35","author":"Gonzalez-Enriquez","year":"2012","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2014.02.009_bib14","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.jacc.2006.03.037","article-title":"A comparison of empiric to physician-tailored programming of implantable cardioverter-defibrillators: results from the prospective randomized multicenter empiric trial","volume":"48","author":"Wilkoff","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2014.02.009_bib15","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1093\/europace\/eut302","article-title":"Safety and efficacy of strategic implantable cardioverter-defibrillator programming to reduce the shock delivery burden in a primary prevention patient population","volume":"16","author":"Buber","year":"2014","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2014.02.009_bib16","doi-asserted-by":"crossref","first-page":"1903","DOI":"10.1001\/jama.2013.4598","article-title":"Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the Advance III randomized clinical trial","volume":"309","author":"Gasparini","year":"2013","journal-title":"JAMA"},{"key":"10.1016\/j.hrthm.2014.02.009_bib17","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1111\/jce.12273","article-title":"Programming implantable cardioverter-defibrillators in patients with primary prevention indication to prolong time to first shock: results from the PROVIDE study","volume":"25","author":"Saeed","year":"2014","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2014.02.009_bib18","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1161\/hc0502.103330","article-title":"Investigators tA. Quality of life in the Antiarrhythmics Versus Implantable Defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks","volume":"105","author":"Schron","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2014.02.009_bib19","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1111\/j.1540-8159.2011.03037.x","article-title":"Programming ICDs in the modern era beyond out-of-the box settings","volume":"34","author":"Mansour","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2014.02.009_bib20","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1016\/j.jacc.2007.09.073","article-title":"Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact","volume":"51","author":"Daubert","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2014.02.009_bib21","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1016\/j.jacc.2010.06.059","article-title":"Inappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality","volume":"57","author":"van Rees","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2014.02.009_bib22","doi-asserted-by":"crossref","first-page":"1674","DOI":"10.1016\/j.jacc.2013.04.083","article-title":"Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked: the Altitude Survival by Rhythm study","volume":"62","author":"Powell","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2014.02.009_bib23","doi-asserted-by":"crossref","first-page":"2591","DOI":"10.1161\/01.CIR.0000145610.64014.E4","volume":"110","author":"Wathen","year":"2004","journal-title":"Circulation"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527114001295?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527114001295?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T06:46:36Z","timestamp":1761547596000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527114001295"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5]]},"references-count":23,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2014,5]]}},"alternative-id":["S1547527114001295"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2014.02.009","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2014,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Impact of prolonged implantable cardioverter-defibrillator arrhythmia detection times on outcomes: A meta-analysis","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2014.02.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}