{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T18:46:59Z","timestamp":1772131619726,"version":"3.50.1"},"reference-count":41,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2015,6,1]],"date-time":"2015-06-01T00:00:00Z","timestamp":1433116800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","heartrhythmjournal.com","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2015,6]]},"DOI":"10.1016\/j.hrthm.2015.03.005","type":"journal-article","created":{"date-parts":[[2015,5,18]],"date-time":"2015-05-18T09:22:23Z","timestamp":1431940943000},"page":"1233-1240","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":40,"title":["Cable externalization and electrical failure of the Riata family of implantable cardioverter-defibrillator leads: A systematic review and meta-analysis"],"prefix":"10.1016","volume":"12","author":[{"given":"Emily P.","family":"Zeitler","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sean D.","family":"Pokorney","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ke","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert K.","family":"Lewis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruth Ann","family":"Greenfield","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James P.","family":"Daubert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David B.","family":"Matchar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan P.","family":"Piccini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2015.03.005_bib1","year":"2011","journal-title":"FDA Classifies Voluntary Physician Advisory Letter on Riata and Riata ST Silicone Defibrillation Leads as Class I Recall (Urgent Medical Device Advisory)"},{"key":"10.1016\/j.hrthm.2015.03.005_bib2","unstructured":"US Food and Drug Administration. FDA Safety Communication: Premature Insulation Failure in Recalled Riata Implantable Cardioverter Defibrillator (ICD) Leads Manufactured by St. Jude Medical, Inc. Available at: http:\/\/www.fda.gov\/MedicalDevices\/Safety\/AlertsandNotices\/ucm314930.htm. Novemeber 20, 2012."},{"key":"10.1016\/j.hrthm.2015.03.005_bib3","doi-asserted-by":"crossref","first-page":"W65","DOI":"10.7326\/0003-4819-151-4-200908180-00136","article-title":"The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration","volume":"151","author":"Liberati","year":"2009","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.hrthm.2015.03.005_bib4","doi-asserted-by":"crossref","first-page":"2008","DOI":"10.1001\/jama.283.15.2008","article-title":"Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group","volume":"283","author":"Stroup","year":"2000","journal-title":"JAMA"},{"key":"10.1016\/j.hrthm.2015.03.005_bib5","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/0197-2456(86)90046-2","article-title":"Meta-analysis in clinical trials","volume":"7","author":"DerSimonian","year":"1986","journal-title":"Control Clin Trials"},{"key":"10.1016\/j.hrthm.2015.03.005_bib6","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.hrthm.2012.10.045","article-title":"Independent multicenter study of Riata and Riata ST implantable cardioverter-defibrillator leads","volume":"10","author":"Abdelhadi","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib7","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1016\/j.hrthm.2013.06.015","article-title":"Mechanisms, predictors and trends of electrical failure of Riata leads","volume":"10","author":"Cheung","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib8","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1111\/j.1540-8167.2011.02055.x","article-title":"Insulation defects of thin high-voltage ICD leads: an underestimated problem?","volume":"22","author":"Erkapic","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib9","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1016\/j.ijcard.2012.10.015","article-title":"Comparison of Sprint Fidelis and Riata defibrillator lead failure rates","volume":"168","author":"Fazal","year":"2012","journal-title":"Int J Cardiology"},{"key":"10.1016\/j.hrthm.2015.03.005_bib10","doi-asserted-by":"crossref","first-page":"1778","DOI":"10.1016\/j.hrthm.2013.08.030","article-title":"Prevalence of externalized conductors in Riata and Riata ST silicone leads: results from the prospective, multicenter Riata Lead Evaluation Study","volume":"10","author":"Hayes","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib11","doi-asserted-by":"crossref","first-page":"1498","DOI":"10.1111\/pace.12010","article-title":"Fluoroscopic and electrical assessment of a series of defibrillation leads: prevalence of externalized conductors","volume":"35","author":"Kodoth","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib12","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1093\/europace\/eut015","article-title":"Progressive decrease in amplitude of intracardiac ventricular electrogram and higher left ventricular ejection fraction are associated with conductors\u05f3 externalization in Riata leads","volume":"15","author":"Kubala","year":"2013","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2015.03.005_bib13","doi-asserted-by":"crossref","first-page":"2141","DOI":"10.1016\/j.hrthm.2014.07.003","article-title":"Prospective nationwide fluoroscopic and electrical longitudinal follow-up of recalled Riata defibrillator leads in Denmark","volume":"11","author":"Larsen","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib14","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.amjcard.2013.08.046","article-title":"Longitudinal follow-up of implantable cardioverter defibrillator leads","volume":"113","author":"Liu","year":"2014","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib15","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/s10840-013-9822-6","article-title":"Prospective evaluation of cinefluoroscopy and chest radiography for Riata lead defects: implications for future lead screening","volume":"38","author":"Lorvidhaya","year":"2013","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib16","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/s10840-012-9760-8","article-title":"Increasing lead burden correlates with externalized cables during systematic fluoroscopic screening of Riata leads","volume":"37","author":"Moorman","year":"2013","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib17","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/j.hrthm.2012.03.049","article-title":"High prevalence of insulation failure with externalized cables in St. Jude Medical Riata family ICD leads: fluoroscopic grading scale and correlation to extracted leads","volume":"9","author":"Parvathaneni","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib18","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.hrthm.2012.10.017","article-title":"Failure of implantable cardioverter-defibrillator leads: a matter of lead size?","volume":"10","author":"Rordorf","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib19","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.ijcard.2011.12.076","article-title":"Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata(R) and Riata(R) ST implantable cardioverter-defibrillator leads","volume":"167","author":"Schmutz","year":"2013","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib20","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1111\/j.1540-8167.2012.02378.x","article-title":"Prevalence and predictors of cable extrusion and loss of electrical integrity with the Riata defibrillator lead","volume":"23","author":"Shen","year":"2012","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib21","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1093\/europace\/eus339","article-title":"Detection of high incidence of Riata lead breaches by systematic postero-anterior and lateral chest X-ray in a large cohort","volume":"15","author":"Steinberg","year":"2013","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2015.03.005_bib22","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1161\/CIRCEP.112.975755","article-title":"Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee","volume":"5","author":"Theuns","year":"2012","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib23","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1007\/s12471-012-0341-3","article-title":"Long-term performance of the St Jude Riata 1580-1582 ICD lead family","volume":"21","author":"Valk","year":"2013","journal-title":"Neth Heart J"},{"key":"10.1016\/j.hrthm.2015.03.005_bib24","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1111\/j.1540-8159.2011.03338.x","article-title":"Update on small-diameter implantable cardioverter-defibrillator leads performance","volume":"35","author":"van Rees","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib25","doi-asserted-by":"crossref","first-page":"1616","DOI":"10.1016\/j.amjcard.2013.07.044","article-title":"Longitudinal follow-up of externalized Riata leads","volume":"112","author":"Liu","year":"2013","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib26","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/j.hrthm.2009.02.020","article-title":"Increased rate of subacute lead complications with small-caliber implantable cardioverter-defibrillator leads","volume":"6","author":"Ellis","year":"2009","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib27","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1016\/j.hrthm.2013.01.018","article-title":"Failure rate of the Riata lead under advisory: a report from the CHRS Device Committee","volume":"10","author":"Parkash","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib28","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1016\/j.hrthm.2012.08.006","article-title":"Long-term electrical survival analysis of Riata and Riata ST silicone leads: National Veterans Affairs experience","volume":"9","author":"Sung","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib29","doi-asserted-by":"crossref","first-page":"1538","DOI":"10.1111\/pace.12473","article-title":"Fluoroscopic and electrical assessment of implantable cardioverter defibrillator leads: a prospective observational study","volume":"37","author":"McKeag","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib30","doi-asserted-by":"crossref","first-page":"1787","DOI":"10.1093\/europace\/euu079","article-title":"Mechanical and electrical dysfunction of Riata implantable cardioverter-defibrillator leads","volume":"16","author":"Demirel","year":"2014","journal-title":"Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology"},{"key":"10.1016\/j.hrthm.2015.03.005_bib31","year":"2011","journal-title":"Medical device advisory: important product information update"},{"key":"10.1016\/j.hrthm.2015.03.005_bib32","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1056\/NEJMp1114865","article-title":"Postmarketing surveillance of medical devices\u2014filling in the gaps","volume":"366","author":"Resnic","year":"2012","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2015.03.005_bib33","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1161\/CIRCULATIONAHA.111.053744","article-title":"Clinical predictors of Fidelis lead failure: report from the Canadian Heart Rhythm Society Device Committee","volume":"125","author":"Birnie","year":"2012","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2015.03.005_bib34","unstructured":"Sprint Fidelis Performance Report. Available at: http:\/\/www.medtronic.com\/product-advisories\/physician\/sprint-fidelis\/6949-LEAD-PERFORMANCE. Accessed April 10, 2015."},{"key":"10.1016\/j.hrthm.2015.03.005_bib35","doi-asserted-by":"crossref","first-page":"443","DOI":"10.7326\/0003-4819-123-6-199509150-00009","article-title":"Expanding indications for permanent pacemakers","volume":"123","author":"Glikson","year":"1995","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.hrthm.2015.03.005_bib36","unstructured":"St. Jude Medical Inc. (2014). Implantable Electronic Systems Division Product Performance Report, 2014 2nd edition. http:\/\/professional-intl.sjm.com\/resources\/product-performance\/product-performance-reports\/archive."},{"key":"10.1016\/j.hrthm.2015.03.005_bib37","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1016\/j.hrthm.2014.04.003","article-title":"Association between serum uric acid and atrial fibrillation: a systematic review and meta-analysis","volume":"11","author":"Tamariz","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib38","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/j.jacc.2012.11.023","article-title":"Early repolarization pattern and risk for arrhythmia death: a meta-analysis","volume":"61","author":"Wu","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib39","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.1111\/jce.12134","article-title":"Lead thrombi associated with externalized cables on Riata ICD leads: a case series","volume":"24","author":"Goyal","year":"2013","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.03.005_bib40","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1016\/j.hrthm.2012.03.048","article-title":"Deaths caused by the failure of Riata and Riata ST implantable cardioverter-defibrillator leads","volume":"9","author":"Hauser","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.03.005_bib41","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1111\/jce.12563","article-title":"Optimal management of Riata leads with no known electrical abnormalities or externalization: a decision analysis","volume":"26","author":"Pokorney","year":"2015","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S154752711500260X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S154752711500260X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T16:13:54Z","timestamp":1657728834000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S154752711500260X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6]]},"references-count":41,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2015,6]]}},"alternative-id":["S154752711500260X"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2015.03.005","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2015,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Cable externalization and electrical failure of the Riata family of implantable cardioverter-defibrillator leads: A systematic review and meta-analysis","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2015.03.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}