{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T06:57:41Z","timestamp":1785394661780,"version":"3.55.0"},"reference-count":21,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2015,10,1]],"date-time":"2015-10-01T00:00:00Z","timestamp":1443657600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","heartrhythmjournal.com","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2015,10]]},"DOI":"10.1016\/j.hrthm.2015.05.011","type":"journal-article","created":{"date-parts":[[2015,6,5]],"date-time":"2015-06-05T15:46:30Z","timestamp":1433519190000},"page":"2162-2169","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":43,"title":["Effect of radiofrequency energy delivery in proximity to metallic medical device components"],"prefix":"10.1016","volume":"12","author":[{"given":"Duy T.","family":"Nguyen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Waseem","family":"Barham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lijun","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Dinegar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wendy S.","family":"Tzou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William H.","family":"Sauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2015.05.011_bib1","doi-asserted-by":"crossref","first-page":"1309","DOI":"10.1016\/j.hrthm.2005.09.010","article-title":"Safety and efficacy of radiofrequency energy catheter ablation of atrial fibrillation in patients with pacemakers and implantable cardiac defibrillators","volume":"2","author":"Lakkireddy","year":"2005","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2015.05.011_bib2","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1161\/CIRCHEARTFAILURE.114.001487","article-title":"Epicardial catheter ablation through subxiphoid surgical approach in a patient with implanted left ventricular assist device and cannula-related ventricular tachycardia","volume":"7","author":"Whang","year":"2014","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.hrthm.2015.05.011_bib3","doi-asserted-by":"crossref","first-page":"e002212","DOI":"10.1161\/JAHA.112.002212","article-title":"Ablation for atrial fibrillation in combination with left atrial appendage closure: first results of a feasibility study","volume":"1","author":"Swaans","year":"2012","journal-title":"J Am Heart Assoc"},{"key":"10.1016\/j.hrthm.2015.05.011_bib4","doi-asserted-by":"crossref","first-page":"e163","DOI":"10.1111\/j.1540-8159.2010.02927.x","article-title":"Impedance changes on defibrillation coils after atrial fibrillation ablation: lead damage or electromechanical interference?","volume":"35","author":"Vanga","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib5","doi-asserted-by":"crossref","unstructured":"Nguyen DT, Moss JD, Zheng L, Huang J, Barham W., Sauer W.H. Effects of radiofrequency energy delivered through partially insulated metallic catheter tips on myocardial tissue heating and ablation lesion characteristics. Heart Rhythm 201;12:623\u2013630.","DOI":"10.1016\/j.hrthm.2014.11.022"},{"key":"10.1016\/j.hrthm.2015.05.011_bib6","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1111\/jce.12509","article-title":"Carbon nanotube facilitation of myocardial ablation with radiofrequency energy","volume":"25","author":"Nguyen","year":"2014","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib7","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s10840-013-9824-4","article-title":"Effect of catheter movement and contact during application of radiofrequency energy on ablation lesion characteristics","volume":"38","author":"Olson","year":"2013","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib8","series-title":"LabVIEW [computer program]. Version 7.0","year":"2003"},{"key":"10.1016\/j.hrthm.2015.05.011_bib9","series-title":"Version 23.0","article-title":"Statistics [computer program]","year":"2015"},{"key":"10.1016\/j.hrthm.2015.05.011_bib10","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1093\/europace\/euu039","article-title":"Catheter ablation of atrial fibrillation and left atrial flutter in a patient with a left atrial appendage occlusion device","volume":"16","author":"Steckman","year":"2014","journal-title":"Europace"},{"issue":"Suppl","key":"10.1016\/j.hrthm.2015.05.011_bib11","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1054\/jelc.2001.28854","article-title":"Effect of radiofrequency current on previously implanted pacemaker and defibrillator ventricular lead systems","volume":"34","author":"Burke","year":"2001","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib12","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.2214\/ajr.180.6.1801557","article-title":"Do surgical clips interfere with radiofrequency thermal ablation?","volume":"180","author":"Boll","year":"2003","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib13","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1080\/13645700600640931","article-title":"MRI-induced heating of selected thin wire metallic implants\u2014laboratory and computational studies\u2014findings and new questions raised","volume":"15","author":"Bassen","year":"2006","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib14","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1002\/bem.20224","article-title":"Interaction of radio frequency electromagnetic fields and passive metallic implants\u2014a brief review","volume":"27","author":"Virtanen","year":"2006","journal-title":"Bioelectromagnetics"},{"key":"10.1016\/j.hrthm.2015.05.011_bib15","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1002\/jmri.1088","article-title":"Investigation of the factors responsible for burns during MRI","volume":"13","author":"Dempsey","year":"2001","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.hrthm.2015.05.011_bib16","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1007\/s00270-007-9174-7","article-title":"Influence of surgical staples on radiofrequency ablation using multitined expandable electrodes","volume":"30","author":"Sakuhara","year":"2007","journal-title":"Cardiovasc Intervent Radiol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib17","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.1161\/CIRCULATIONAHA.105.551291","article-title":"Anatomic relations between the esophagus and left atrium and relevance for ablation of atrial fibrillation","volume":"112","author":"S\u00e1nchez-Quintana","year":"2005","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2015.05.011_bib18","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1111\/j.1540-8167.2010.01916.x","article-title":"Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation","volume":"22","author":"Deneke","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib19","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1111\/jce.12180","article-title":"Multisensor esophageal temperature probe used during radiofrequency ablation for atrial fibrillation is associated with increased intraluminal temperature detection and increased risk of esophageal injury compared with single-sensor probe","volume":"24","author":"Carroll","year":"2013","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib20","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1111\/jce.12198","article-title":"Luminal esophageal temperature monitoring for the prevention of esophageal injury during left atrial ablation: LET it be?","volume":"24","author":"Tzou","year":"2013","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2015.05.011_bib21","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1111\/j.1540-8167.2010.01936.x","article-title":"The esophageal temperature probe: helpful monitoring device or inadvertent amplifier of risk?","volume":"22","author":"Musat","year":"2011","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527115005688?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527115005688?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T16:16:27Z","timestamp":1657728987000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527115005688"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,10]]},"references-count":21,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2015,10]]}},"alternative-id":["S1547527115005688"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2015.05.011","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2015,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of radiofrequency energy delivery in proximity to metallic medical device components","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2015.05.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}