{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T03:30:25Z","timestamp":1778815825763,"version":"3.51.4"},"reference-count":20,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2016,11,1]],"date-time":"2016-11-01T00:00:00Z","timestamp":1477958400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","award":["NCT00740870"],"award-info":[{"award-number":["NCT00740870"]}],"id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","heartrhythmjournal.com","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2016,11]]},"DOI":"10.1016\/j.hrthm.2016.07.023","type":"journal-article","created":{"date-parts":[[2016,7,22]],"date-time":"2016-07-22T04:20:44Z","timestamp":1469161244000},"page":"2135-2141","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":15,"title":["A prospective 5-year study of the frequency of arrhythmias during serial exercise testing and clinical follow-up after Melody valve implant"],"prefix":"10.1016","volume":"13","author":[{"given":"Bryant","family":"Priromprintr","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael J.","family":"Silka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Rhodes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anjan S.","family":"Batra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2016.07.023_bib1","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1016\/S0140-6736(00)02844-0","article-title":"Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction","volume":"356","author":"Bonhoeffer","year":"2000","journal-title":"Lancet"},{"key":"10.1016\/j.hrthm.2016.07.023_bib2","doi-asserted-by":"crossref","first-page":"1722","DOI":"10.1016\/j.jacc.2009.06.034","article-title":"Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit early results from the U.S. clinical trial","volume":"54","author":"Zahn","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2016.07.023_bib3","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1161\/CIRCINTERVENTIONS.111.965616","article-title":"Stent fracture, valve dysfunction, and right ventricular outflow tract reintervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US Melody Valve Trial.","volume":"4","author":"McElhinney","year":"2011","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2016.07.023_bib4","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1161\/CIRCULATIONAHA.109.921692","article-title":"Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US Melody Valve Trial","volume":"122","author":"McElhinney","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2016.07.023_bib5","doi-asserted-by":"crossref","first-page":"1960","DOI":"10.1161\/CIRCULATIONAHA.114.013588","article-title":"Clinical and hemodynamic outcomes up to 7 years after transcatheter pulmonary valve replacement in the US Melody Valve Investigational Device Exemption Trial","volume":"131","author":"Cheatham","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2016.07.023_bib6","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1161\/CIRCULATIONAHA.109.928481","article-title":"Arrhythmia burden in adults with surgically repaired tetralogy of Fallot: a multi-institutional study","volume":"122","author":"Khairy","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2016.07.023_bib7","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/S0140-6736(00)02714-8","article-title":"Risk factors for arrhythmia and sudden cardiac death late after repair of tetralogy of Fallot: a multicentre study","volume":"356","author":"Gatzoulis","year":"2000","journal-title":"Lancet"},{"key":"10.1016\/j.hrthm.2016.07.023_bib8","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1016\/j.jacc.2006.05.051","article-title":"Heart rate response during exercise predicts survival in adults with congenital heart disease","volume":"48","author":"Diller","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2016.07.023_bib9","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1161\/CIRCULATIONAHA.113.001485","article-title":"Clinical outcomes of surgical pulmonary valve replacement after repair of tetralogy of Fallot and potential prognostic value of preoperative cardiopulmonary exercise testing","volume":"129","author":"Babu-Narayan","year":"2014","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2016.07.023_bib10","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/j.amjcard.2014.05.019","article-title":"Prevalence of arrhythmias during exercise stress testing in patients with congenital heart disease and severe right ventricular conduit dysfunction","volume":"114","author":"Priromprintr","year":"2014","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.hrthm.2016.07.023_bib11","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.jacc.2008.02.081","article-title":"Pediatric Heart Network Investigators. A cross-sectional study of exercise performance during the first 2 decades of life after the Fontan operation","volume":"52","author":"Paridon","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2016.07.023_bib12","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.ahj.2011.10.017","article-title":"Cardiopulmonary exercise function among patients undergoing transcatheter pulmonary valve implantation in the US Melody Valve Investigational Trial","volume":"163","author":"Batra","year":"2012","journal-title":"Am Heart J"},{"key":"10.1016\/j.hrthm.2016.07.023_bib13","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1016\/j.jcin.2014.08.002","article-title":"One-year follow-up of the Melody transcatheter pulmonary valve multicenter post-approval study","volume":"7","author":"Armstrong","year":"2014","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2016.07.023_bib14","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1002\/ccd.24518","article-title":"Melody transcatheter pulmonary valve implantation. Results from the registry of the Italian Society of Pediatric Cardiology","volume":"81","author":"Butera","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2016.07.023_bib15","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.1093\/eurheartj\/ehq520","article-title":"Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients","volume":"32","author":"Eicken","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2016.07.023_bib16","doi-asserted-by":"crossref","first-page":"1964","DOI":"10.1161\/CIRCULATIONAHA.107.735779","article-title":"Percutaneous pulmonary valve implantation: impact of evolving technology and learning curve on clinical outcome","volume":"117","author":"Lurz","year":"2008","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2016.07.023_bib17","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1161\/CIRCULATIONAHA.107.726372","article-title":"Implantable cardioverter-defibrillators in tetralogy of Fallot","volume":"117","author":"Khairy","year":"2008","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2016.07.023_bib18","doi-asserted-by":"crossref","first-page":"1735","DOI":"10.1016\/j.hrthm.2014.07.021","article-title":"Sudden death in adult congenital heart disease: risk stratification in 2014","volume":"11","author":"Walsh","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2016.07.023_bib19","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1161\/01.CIR.92.2.231","article-title":"Mechanoelectrical interaction in tetralogy of Fallot. QRS prolongation relates to right ventricular size and predicts malignant ventricular arrhythmias and sudden death","volume":"92","author":"Gatzoulis","year":"1995","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2016.07.023_bib20","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1161\/CIRCULATIONAHA.108.775221","article-title":"Pulmonary valve replacement in tetralogy of Fallot: impact on survival and ventricular tachycardia","volume":"119","author":"Harrild","year":"2009","journal-title":"Circulation"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527116305537?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527116305537?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T17:33:42Z","timestamp":1657733622000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527116305537"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11]]},"references-count":20,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2016,11]]}},"alternative-id":["S1547527116305537"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2016.07.023","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2016,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A prospective 5-year study of the frequency of arrhythmias during serial exercise testing and clinical follow-up after Melody valve implant","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2016.07.023","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}