{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T04:01:49Z","timestamp":1780372909594,"version":"3.54.1"},"reference-count":25,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2017,7,1]],"date-time":"2017-07-01T00:00:00Z","timestamp":1498867200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,4,4]],"date-time":"2017-04-04T00:00:00Z","timestamp":1491264000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.jp","heartrhythmjournal.com","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2017,7]]},"DOI":"10.1016\/j.hrthm.2017.03.037","type":"journal-article","created":{"date-parts":[[2017,4,1]],"date-time":"2017-04-01T02:03:25Z","timestamp":1491012205000},"page":"1016-1023","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":22,"title":["Development and validation of a dual sensing scheme to improve accuracy of bradycardia and pause detection in an insertable cardiac monitor"],"prefix":"10.1016","volume":"14","author":[{"given":"Rod S.","family":"Passman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John D.","family":"Rogers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shantanu","family":"Sarkar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jerry","family":"Reiland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erin","family":"Reisfeld","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jodi","family":"Koehler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suneet","family":"Mittal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2017.03.037_bib1","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1093\/europace\/eup097","article-title":"Indications for the use of diagnostic implantable and external ECG loop recorders","volume":"11","author":"Brignole","year":"2009","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2017.03.037_bib2","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/S0735-1097(02)02928-5","article-title":"Syncope: is a diagnosis a diagnosis?","volume":"41","author":"Benditt","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib3","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1016\/S0735-1097(02)02929-7","article-title":"Selective use of diagnostic tests in patients with syncope of unknown cause","volume":"41","author":"Garcia-Civera","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib4","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1046\/j.1460-9592.2003.00061.x","article-title":"Cardiac arrhythmias and risk stratification after myocardial infarction: results of the CARISMA pilot study","volume":"26","author":"Huikuri","year":"2003","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib5","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1111\/j.1540-8159.2004.00502.x","article-title":"Insertable loop recorder use for detection of intermittent arrhythmias","volume":"27","author":"Krahn","year":"2004","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib6","doi-asserted-by":"crossref","first-page":"2212","DOI":"10.1016\/S0140-6736(04)17594-6","article-title":"Cardiac arrhythmias in focal epilepsy: a prospective long-term study","volume":"364","author":"Rugg-Gunn","year":"2004","journal-title":"Lancet"},{"key":"10.1016\/j.hrthm.2017.03.037_bib7","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1161\/CIRCEP.109.877852","article-title":"Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: results of the XPECT trial","volume":"3","author":"Hindricks","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib8","doi-asserted-by":"crossref","first-page":"2478","DOI":"10.1056\/NEJMoa1313600","article-title":"Cryptogenic stroke and underlying atrial fibrillation","volume":"370","author":"Sanna","year":"2014","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2017.03.037_bib9","doi-asserted-by":"crossref","first-page":"S177","DOI":"10.1161\/CIRCULATIONAHA.108.838474","article-title":"Twenty four-hour Holter monitor follow-up does not provide accurate heart rhythm status after surgical atrial fibrillation ablation therapy: up to 12 months experience with a novel permanently implantable heart rhythm monitor device","volume":"120","author":"Hanke","year":"2009","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2017.03.037_bib10","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1001\/jamainternmed.2013.1561","article-title":"Discerning the incidence of symptomatic and asymptomatic episodes of atrial fibrillation before and after catheter ablation (DISCERN AF): a prospective, multicenter study","volume":"173","author":"Verma","year":"2013","journal-title":"JAMA Intern Med"},{"key":"10.1016\/j.hrthm.2017.03.037_bib11","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/S0002-9149(03)00889-0","article-title":"Comparison of automatic and patient-activated arrhythmia recordings by implantable loop recorders in the evaluation of syncope","volume":"92","author":"Ermis","year":"2003","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib12","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1016\/j.ahj.2004.01.024","article-title":"Detection of asymptomatic arrhythmias in unexplained syncope","volume":"148","author":"Krahn","year":"2004","journal-title":"Am Heart J"},{"key":"10.1016\/j.hrthm.2017.03.037_bib13","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1023\/B:JICE.0000019268.95018.91","article-title":"Arrhythmia detection by patient and autoactivation in implantable loop recorders","volume":"10","author":"Ng","year":"2004","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib14","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1053\/eupc.2002.0301","article-title":"Sensing issues related to the clinical use of implantable loop recorders","volume":"5","author":"Chrysostomakis","year":"2003","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2017.03.037_bib15","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ijcard.2006.04.044","article-title":"Risk of cellular phone interference with an implantable loop recorder","volume":"116","author":"Trigano","year":"2007","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib16","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1111\/j.1540-8159.2008.00994.x","article-title":"Feasibility of magnetic resonance imaging in patients with an implantable loop recorder","volume":"31","author":"Wong","year":"2008","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib17","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1111\/j.1540-8167.2008.01156.x","article-title":"Improved arrhythmia detection in implantable loop recorders","volume":"19","author":"Brignole","year":"2008","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.03.037_bib18","doi-asserted-by":"crossref","first-page":"S206","DOI":"10.1016\/j.hrthm.2006.02.619","article-title":"Insertable loop recorder R wave sensing performance is improved with dynamic threshold adjustment","volume":"3","author":"Cao","year":"2006","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.03.037_bib19","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1093\/europace\/euq511","article-title":"Performance of an implantable automatic atrial fibrillation detection device: impact of software adjustments and relevance of manual episode analysis","volume":"13","author":"Eitel","year":"2011","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2017.03.037_bib20","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1093\/europace\/eut036","article-title":"Tachycardia detection performance of implantable loop recorders: results from a large \u201creal-life\u201d patient cohort and patients with induced ventricular arrhythmias","volume":"15","author":"Volosin","year":"2013","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2017.03.037_bib21","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1016\/j.hrthm.2014.06.006","article-title":"P-wave evidence as a method for improving algorithm to detect atrial fibrillation in insertable cardiac monitors","volume":"11","author":"P\u00fcrerfellner","year":"2014","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.03.037_bib22","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1016\/j.hrthm.2015.02.030","article-title":"Miniaturized Reveal LINQ insertable cardiac monitoring system: first-in-human experience","volume":"12","author":"P\u00fcrerfellner","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.03.037_bib23","doi-asserted-by":"crossref","first-page":"1425","DOI":"10.1016\/j.hrthm.2016.03.005","article-title":"Performance of a new AF detection algorithm in a miniaturized insertable cardiac monitor: results from the Reveal LINQ Usability Study","volume":"13","author":"Sanders","year":"2016","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.03.037_bib24","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.2307\/2531734","article-title":"Models for longitudinal data: a generalized estimating equation approach","volume":"44","author":"Zeger","year":"1988","journal-title":"Biometrics"},{"key":"10.1016\/j.hrthm.2017.03.037_bib25","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1097\/EDE.0000000000000018","article-title":"Net reclassification indices for evaluating risk-prediction instruments: a critical review","volume":"25","author":"Kerr","year":"2014","journal-title":"Epidemiology"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527117304149?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527117304149?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,2]],"date-time":"2018-09-02T22:27:06Z","timestamp":1535927226000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527117304149"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7]]},"references-count":25,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2017,7]]}},"alternative-id":["S1547527117304149"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2017.03.037","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2017,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Development and validation of a dual sensing scheme to improve accuracy of bradycardia and pause detection in an insertable cardiac monitor","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2017.03.037","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 The Authors. Published by Elsevier Inc. on behalf of Heart Rhythm Society.","name":"copyright","label":"Copyright"}]}}