{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T08:52:51Z","timestamp":1789203171130,"version":"build-2803163510"},"reference-count":26,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2017,9,1]],"date-time":"2017-09-01T00:00:00Z","timestamp":1504224000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100006279","name":"St. Jude Medical","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006279","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004331","name":"Johnson and Johnson","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004331","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007497","name":"Biosense Webster","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008497","name":"Boston Scientific Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000038","name":"U.S. Food and Drug Administration","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000038","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100002491","name":"Bristol-Myers Squibb","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100002491","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100005564","name":"Gilead Sciences","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100005564","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","heartrhythmjournal.com","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2017,9]]},"DOI":"10.1016\/j.hrthm.2017.04.024","type":"journal-article","created":{"date-parts":[[2017,4,15]],"date-time":"2017-04-15T02:17:21Z","timestamp":1492222641000},"page":"1328-1333","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":92,"title":["Risk of atrioesophageal fistula formation with contact force\u2013sensing catheters"],"prefix":"10.1016","volume":"14","author":[{"given":"Eric","family":"Black-Maier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sean D.","family":"Pokorney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam S.","family":"Barnett","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emily P.","family":"Zeitler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albert Y.","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin P.","family":"Jackson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tristram D.","family":"Bahnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James P.","family":"Daubert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan P.","family":"Piccini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2017.04.024_bib1","doi-asserted-by":"crossref","first-page":"1798","DOI":"10.1016\/j.jacc.2009.02.022","article-title":"Prevalence and causes of fatal outcome in catheter ablation of atrial fibrillation","volume":"53","author":"Cappato","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib2","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1007\/s10840-008-9307-1","article-title":"A nationwide survey on the prevalence of atrioesophageal fistula after left atrial radiofrequency catheter ablation","volume":"24","author":"Ghia","year":"2009","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib3","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1016\/j.jacc.2014.12.053","article-title":"Global survey of esophageal and gastric injury in atrial fibrillation ablation: incidence, time to presentation, and outcomes","volume":"65","author":"Barbhaiya","year":"2015","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib4","doi-asserted-by":"crossref","first-page":"2368","DOI":"10.1161\/CIRCULATIONAHA.110.946806","article-title":"Long-term results of\u00a0catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up","volume":"122","author":"Ouyang","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2017.04.024_bib5","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","article-title":"Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial","volume":"64","author":"Natale","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib6","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1161\/CIRCULATIONAHA.114.014092","volume":"132","author":"Reddy","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2017.04.024_bib7","doi-asserted-by":"crossref","first-page":"1990","DOI":"10.1016\/j.hrthm.2015.06.026","article-title":"Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: a systematic review and meta-analysis","volume":"12","author":"Afzal","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.04.024_bib8","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1016\/j.hrthm.2012.07.016","article-title":"The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study","volume":"9","author":"Reddy","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.04.024_bib9","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1161\/CIRCEP.113.000374","article-title":"Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study","volume":"6","author":"Neuzil","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib10","doi-asserted-by":"crossref","first-page":"e002476","DOI":"10.1161\/JAHA.115.002476","article-title":"Impact of contact force technology on atrial fibrillation ablation: a meta-analysis","volume":"4","author":"Shurrab","year":"2015","journal-title":"J Am Heart Assoc"},{"key":"10.1016\/j.hrthm.2017.04.024_bib11","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1067\/mtc.2001.118041","article-title":"Esophageal injury during radiofrequency ablation for atrial fibrillation","volume":"122","author":"Gillinov","year":"2001","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.hrthm.2017.04.024_bib12","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1161\/CIRCEP.113.001094","volume":"7","author":"Ikeda","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib13","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1111\/j.1540-8167.2009.01693.x","article-title":"Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex\u00a0vivo model using a force-sensing catheter","volume":"21","author":"Thiagalingam","year":"2010","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib14","doi-asserted-by":"crossref","unstructured":"Bhaskaran A, Chik W, Pouliopoulos J, Nalliah C, Qian P, Barry T, Nadri F, Samanta R, Tran Y, Thomas S, Kovoor P, Thiagalingam A. Five seconds of 50-60 W radio frequency atrial ablations were transmural and safe: an in\u00a0vitro mechanistic assessment and force-controlled in\u00a0vivo validation [published online ahead of print May 20, 2016]. Europace.pii: euw077.","DOI":"10.1093\/europace\/euw077"},{"key":"10.1016\/j.hrthm.2017.04.024_bib15","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1111\/jce.12386","article-title":"Outcomes of atrioesophageal fistula following catheter ablation of atrial fibrillation treated with surgical repair versus esophageal stenting","volume":"25","author":"Mohanty","year":"2014","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib16","doi-asserted-by":"crossref","first-page":"1591","DOI":"10.1016\/j.hrthm.2013.08.012","article-title":"Clinical outcomes after repair of left atrial esophageal fistulas occurring after atrial fibrillation ablation procedures","volume":"10","author":"Singh","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.04.024_bib17","doi-asserted-by":"crossref","first-page":"e000257","DOI":"10.1136\/openhrt-2015-000257","article-title":"Atrioesophageal fistula following ablation procedures for atrial fibrillation: systematic review of case reports","volume":"2","author":"Chavez","year":"2015","journal-title":"Open Heart"},{"key":"10.1016\/j.hrthm.2017.04.024_bib18","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1161\/CIRCEP.108.789552","article-title":"Esophageal injury and temperature monitoring during atrial fibrillation ablation","volume":"1","author":"Singh","year":"2008","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib19","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1161\/CIRCEP.108.815266","article-title":"Esophageal capsule endoscopy after radiofrequency catheter ablation for atrial fibrillation: documented higher risk of luminal esophageal damage with general anesthesia as compared with conscious sedation","volume":"2","author":"Di Biase","year":"2009","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib20","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1111\/j.1540-8167.2008.01130.x","article-title":"Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: comparison between 8 mm tip and open irrigation catheters","volume":"19","author":"Cummings","year":"2008","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2017.04.024_bib21","doi-asserted-by":"crossref","first-page":"2195","DOI":"10.1016\/j.hrthm.2016.07.021","article-title":"Difference in thermodynamics between two types of esophageal temperature probes: insights from an experimental study","volume":"13","author":"Gianni","year":"2016","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.04.024_bib22","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.1016\/j.hrthm.2015.04.005","article-title":"Higher incidence of esophageal lesions after ablation of atrial fibrillation related to the use of esophageal temperature probes","volume":"12","author":"Muller","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.04.024_bib23","doi-asserted-by":"crossref","first-page":"2162","DOI":"10.1016\/j.hrthm.2015.05.011","article-title":"Effect of radiofrequency energy delivery in proximity to metallic medical device components","volume":"12","author":"Nguyen","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2017.04.024_bib24","first-page":"58785","article-title":"Unique device identification system; final rule","volume":"78","author":"Food and Drug Administration, HHS","year":"2013","journal-title":"Fed Regist"},{"key":"10.1016\/j.hrthm.2017.04.024_bib25","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1001\/jamainternmed.2015.1513","article-title":"Safety and procedural success of left atrial appendage exclusion with the Lariat device: a systematic review of published reports and analytic review of the FDA MAUDE database","volume":"175","author":"Chatterjee","year":"2015","journal-title":"JAMA Intern Med"},{"key":"10.1016\/j.hrthm.2017.04.024_bib26","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.hrthm.2016.10.018","article-title":"Atrioesophageal fistula formation with cryoballoon ablation is most commonly related to the left inferior pulmonary vein","volume":"14","author":"John","year":"2017","journal-title":"Heart Rhythm"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527117304526?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527117304526?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,6,23]],"date-time":"2024-06-23T15:55:25Z","timestamp":1719158125000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527117304526"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9]]},"references-count":26,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2017,9]]}},"alternative-id":["S1547527117304526"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2017.04.024","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2017,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Risk of atrioesophageal fistula formation with contact force\u2013sensing catheters","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2017.04.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}