{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T18:10:15Z","timestamp":1786990215648,"version":"build-2736575974"},"reference-count":24,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T00:00:00Z","timestamp":1559347200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"Sun Chieh Yeh Heart Foundation"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","heartrhythmjournal.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2019,6]]},"DOI":"10.1016\/j.hrthm.2018.12.007","type":"journal-article","created":{"date-parts":[[2018,12,11]],"date-time":"2018-12-11T12:41:34Z","timestamp":1544532094000},"page":"896-902","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":41,"title":["Safety and feasibility of a midseptal implantation technique of a leadless pacemaker"],"prefix":"10.1016","volume":"16","author":[{"given":"Jo-Jo","family":"Hai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Fang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chor-Cheung","family":"Tam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun-Ka","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ka-Chun","family":"Un","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chung-Wah","family":"Siu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chu-Pak","family":"Lau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hung-Fat","family":"Tse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2018.12.007_bib1","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1016\/j.jacc.2012.12.014","volume":"61","author":"Epstein","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2018.12.007_bib2","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1093\/europace\/eut206","volume":"15","author":"Brignole","year":"2013","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2018.12.007_bib3","doi-asserted-by":"crossref","first-page":"604","DOI":"10.7326\/0003-4819-133-8-200010170-00011","article-title":"Diagnosis and management of infections involving implantable electrophysiologic cardiac devices","volume":"133","author":"Chua","year":"2000","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.hrthm.2018.12.007_bib4","doi-asserted-by":"crossref","first-page":"1622","DOI":"10.1016\/j.hrthm.2011.04.014","article-title":"Risk factors for lead complications in cardiac pacing: a population-based cohort study of 28,860 Danish patients","volume":"8","author":"Kirkfeldt","year":"2011","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2018.12.007_bib5","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1093\/eurheartj\/ehq497","article-title":"Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients","volume":"32","author":"Johansen","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2018.12.007_bib6","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1016\/j.hrthm.2011.12.014","article-title":"Incidence and predictors of short- and long-term complications in pacemaker therapy: the FOLLOWPACE study","volume":"9","author":"Udo","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2018.12.007_bib7","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1093\/eurheartj\/eht511","article-title":"Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark","volume":"35","author":"Kirkfeldt","year":"2014","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2018.12.007_bib8","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1016\/j.jacc.2005.02.037","article-title":"Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads","volume":"45","author":"Lin","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2018.12.007_bib9","doi-asserted-by":"crossref","first-page":"2510","DOI":"10.1093\/eurheartj\/ehv214","article-title":"Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study","volume":"36","author":"Ritter","year":"2015","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2018.12.007_bib10","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1056\/NEJMoa1511643","article-title":"A leadless intracardiac transcatheter pacing system","volume":"374","author":"Reynolds","year":"2016","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2018.12.007_bib11","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/j.hrthm.2017.01.035","article-title":"Long-term performance of a transcatheter pacing system: 12-month results from the Micra Transcatheter Pacing Study","volume":"14","author":"Duray","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2018.12.007_bib12","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1016\/j.hrthm.2017.05.017","article-title":"A leadless pacemaker in the real-world setting: the Micra Transcatheter Pacing System Post-Approval Registry","volume":"14","author":"Roberts","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2018.12.007_bib13","doi-asserted-by":"crossref","first-page":"825","DOI":"10.7326\/0003-4819-158-11-201306040-00007","article-title":"Kidney Disease: Improving Global Outcomes Chronic Kidney Disease Guideline Development Work Group Members. Evaluation and management of chronic kidney disease: synopsis of the kidney disease: improving global outcomes 2012 clinical practice guideline","volume":"158","author":"Stevens","year":"2013","journal-title":"Ann Intern Med"},{"issue":"Suppl 1","key":"10.1016\/j.hrthm.2018.12.007_bib14","doi-asserted-by":"crossref","first-page":"i2","DOI":"10.1136\/hrt.2005.077875","article-title":"Anatomy, echocardiography, and normal right ventricular dimensions","volume":"92","author":"Ho","year":"2006","journal-title":"Heart"},{"key":"10.1016\/j.hrthm.2018.12.007_bib15","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1093\/europace\/eur404","article-title":"Comparison of tools and techniques for implanting pacemaker leads on the ventricular mid-septum","volume":"14","author":"Burri","year":"2012","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2018.12.007_bib16","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1161\/CIRCEP.113.000232","article-title":"The insufficiency of left anterior oblique and the usefulness of right anterior oblique projection for correct localization of a computed tomography-verified right ventricular lead into the midseptum","volume":"6","author":"Osmancik","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2018.12.007_bib17","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1111\/pace.12301","article-title":"Validation of conventional fluoroscopic and ECG criteria for right ventricular pacemaker lead position using cardiac computed tomography","volume":"37","author":"Pang","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2018.12.007_bib18","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.1111\/j.1540-8159.2011.03129.x","article-title":"Alternate site right ventricular pacing: defining template scoring","volume":"34","author":"Mond","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2018.12.007_bib19","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1007\/s10554-016-0840-1","article-title":"A randomized comparison of fluoroscopic techniques for implanting pacemaker lead on the right ventricular outflow tract septum","volume":"32","author":"Chen","year":"2016","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.hrthm.2018.12.007_bib20","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1111\/jce.13256","article-title":"Right ventricular pacemaker lead position is associated with differences in long-term outcomes and complications","volume":"28","author":"Witt","year":"2017","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2018.12.007_bib21","doi-asserted-by":"crossref","first-page":"2932","DOI":"10.1161\/01.CIR.0000072769.17295.B1","article-title":"MOde Selection Trial Investigators. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction","volume":"107","author":"Sweeney","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2018.12.007_bib22","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1016\/S0735-1097(96)00586-4","article-title":"Long-term effect of right ventricular pacing on myocardial perfusion and function","volume":"29","author":"Tse","year":"1997","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2018.12.007_bib23","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1016\/S0735-1097(02)02169-1","article-title":"Functional abnormalities in patients with permanent right ventricular pacing: the effect of sites of electrical stimulation","volume":"40","author":"Tse","year":"2002","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2018.12.007_bib24","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1093\/europace\/euy116","article-title":"Feasibility and long-term effectiveness of a non-apical Micra pacemaker implantation in a referral centre for lead extraction","volume":"21","author":"Bongiorni","year":"2019","journal-title":"Europace"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527118312621?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527118312621?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T05:08:21Z","timestamp":1559106501000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527118312621"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6]]},"references-count":24,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,6]]}},"alternative-id":["S1547527118312621"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2018.12.007","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2019,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Safety and feasibility of a midseptal implantation technique of a leadless pacemaker","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2018.12.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Heart Rhythm Society. All rights reserved.","name":"copyright","label":"Copyright"}]}}