{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T15:43:22Z","timestamp":1784648602540,"version":"3.55.0"},"reference-count":50,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T00:00:00Z","timestamp":1696464000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002996","name":"Hartstichting","doi-asserted-by":"publisher","award":["2021T016"],"award-info":[{"award-number":["2021T016"]}],"id":[{"id":"10.13039\/501100002996","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2024,2]]},"DOI":"10.1016\/j.hrthm.2023.10.003","type":"journal-article","created":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T20:50:21Z","timestamp":1696625421000},"page":"197-205","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Left ventricular lead placement in cardiac resynchronization therapy: Current data and potential explanations for the lack of benefit"],"prefix":"10.1016","volume":"21","author":[{"given":"Uy\u00ean Ch\u00e2u","family":"Nguy\u00ean","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frits W.","family":"Prinzen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Vernooy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2023.10.003_bib1","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1056\/NEJMoa0906431","article-title":"Cardiac-resynchronization therapy for the prevention of heart-failure events","volume":"361","author":"Moss","year":"2009","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2023.10.003_bib2","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1093\/europace\/euu221","article-title":"Left ventricular lead placement in the latest activated region guided by coronary venous electroanatomic mapping","volume":"17","author":"Rad","year":"2015","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2023.10.003_bib3","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1007\/s12471-015-0777-3","article-title":"Identifying delayed left ventricular lateral wall activation in patients with non-specific intraventricular conduction delay using coronary venous electroanatomical mapping","volume":"24","author":"van Stipdonk","year":"2016","journal-title":"Neth Heart J"},{"key":"10.1016\/j.hrthm.2023.10.003_bib4","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1016\/j.jacep.2018.07.006","article-title":"Left ventricular lead location and long-term outcomes in cardiac resynchronization therapy patients","volume":"4","author":"Kutyifa","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib5","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1111\/j.1540-8167.2009.01444.x","article-title":"Influence of left ventricular lead location on outcomes in the COMPANION study","volume":"20","author":"Saxon","year":"2009","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib6","first-page":"413","article-title":"Left ventricular lead position and outcomes in the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT)","volume":"30","author":"Wilton","year":"2014","journal-title":"Can J Cardiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib7","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.117.008508","article-title":"Long-term outcomes of cardiac resynchronization therapy using apical versus nonapical left ventricular pacing","volume":"7","author":"Leyva","year":"2018","journal-title":"J Am Heart Assoc"},{"key":"10.1016\/j.hrthm.2023.10.003_bib8","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1016\/j.hrthm.2007.05.023","article-title":"Variability of coronary venous anatomy in patients undergoing cardiac resynchronization therapy: a high-speed rotational venography study","volume":"4","author":"Blendea","year":"2007","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2023.10.003_bib9","doi-asserted-by":"crossref","first-page":"1832","DOI":"10.1016\/j.jacc.2006.07.042","article-title":"Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography","volume":"48","author":"Van de Veire","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib10","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1093\/ehjci\/jes270","article-title":"Cardiac magnetic resonance-derived anatomy, scar, and dyssynchrony fused with fluoroscopy to guide LV lead placement in cardiac resynchronization therapy: a comparison with acute haemodynamic measures and echocardiographic reverse remodelling","volume":"14","author":"Shetty","year":"2013","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.hrthm.2023.10.003_bib11","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1007\/s12471-018-1132-2","article-title":"Visualisation of coronary venous anatomy by computed tomography angiography prior to cardiac resynchronisation therapy implantation","volume":"26","author":"Nguy\u00ean","year":"2018","journal-title":"Neth Heart J"},{"key":"10.1016\/j.hrthm.2023.10.003_bib12","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1186\/1532-429X-13-29","article-title":"Cardiac resynchronization therapy guided by late gadolinium-enhancement cardiovascular magnetic resonance","volume":"13","author":"Leyva","year":"2011","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1016\/j.hrthm.2023.10.003_bib13","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.jchf.2013.11.010","article-title":"Prognostic benefit of optimum left ventricular lead position in cardiac resynchronization therapy: follow-up of the TARGET Study Cohort (Targeted Left Ventricular Lead Placement to guide Cardiac Resynchronization Therapy)","volume":"2","author":"Kydd","year":"2014","journal-title":"JACC Heart Fail"},{"key":"10.1016\/j.hrthm.2023.10.003_bib14","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1016\/j.echo.2014.01.025","article-title":"The association of left ventricular lead position related to regional scar by speckle-tracking echocardiography with clinical outcomes in patients receiving cardiac resynchronization therapy","volume":"27","author":"Sade","year":"2014","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.hrthm.2023.10.003_bib15","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1016\/j.hrthm.2006.07.034","article-title":"Left ventricular lead electrical delay predicts response to cardiac resynchronization therapy","volume":"3","author":"Singh","year":"2006","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2023.10.003_bib16","doi-asserted-by":"crossref","first-page":"2516","DOI":"10.1093\/eurheartj\/ehr329","article-title":"The relationship between ventricular electrical delay and left ventricular remodelling with cardiac resynchronization therapy","volume":"32","author":"Gold","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2023.10.003_bib17","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1161\/CIRCEP.113.000850","article-title":"Determination of the longest intrapatient left ventricular electrical delay may predict acute hemodynamic improvement in patients after cardiac resynchronization therapy","volume":"7","author":"Zanon","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib18","doi-asserted-by":"crossref","first-page":"5935","DOI":"10.3390\/jcm10245935","article-title":"Left ventricular lead placement guided by reduction in QRS area","volume":"10","author":"Ghossein","year":"2021","journal-title":"J Clin Med"},{"key":"10.1016\/j.hrthm.2023.10.003_bib19","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1111\/jce.14910","article-title":"Reduction in the QRS area after cardiac resynchronization therapy is associated with survival and echocardiographic response","volume":"32","author":"Ghossein","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib20","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.117.005912","article-title":"Can we use the intrinsic left ventricular delay (QLV) to optimize the pacing configuration for cardiac resynchronization therapy with a quadripolar left ventricular lead?","volume":"11","author":"van Everdingen","year":"2018","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib21","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1016\/j.jacep.2020.04.034","article-title":"Targeted left ventricular lead implantation strategy for non-left bundle branch block patients: the ENHANCE CRT Study","volume":"6","author":"Singh","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib22","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1111\/jce.13120","article-title":"Three-dimensional electroanatomic mapping system-enhanced cardiac resynchronization therapy device implantation: results from a multicenter registry","volume":"28","author":"Del Greco","year":"2017","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib23","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.hrthm.2016.09.015","article-title":"A novel approach for left ventricular lead placement in cardiac resynchronization therapy: intraprocedural integration of coronary venous electroanatomic mapping with delayed enhancement cardiac magnetic resonance imaging","volume":"14","author":"Nguy\u00ean","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2023.10.003_bib24","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.hrthm.2022.11.015","article-title":"Electrocardiogram Belt guidance for left ventricular lead placement and biventricular pacing optimization","volume":"20","author":"Rickard","year":"2023","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2023.10.003_bib25","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.1093\/europace\/euad041","article-title":"Non-invasive three-dimensional electrical activation mapping to predict cardiac resynchronization therapy response: site of latest left ventricular activation relative to pacing site","volume":"25","author":"Parreira","year":"2023","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2023.10.003_bib26","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1093\/europace\/euy292","article-title":"Integration of cardiac magnetic resonance imaging, electrocardiographic imaging, and coronary venous computed tomography angiography for guidance of left ventricular lead positioning","volume":"21","author":"Nguy\u00ean","year":"2019","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2023.10.003_bib27","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1016\/j.jacc.2011.12.030","article-title":"Targeted left ventricular lead placement to guide cardiac resynchronization therapy: the TARGET study: a randomized, controlled trial","volume":"59","author":"Khan","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib28","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1161\/CIRCHEARTFAILURE.112.000078","article-title":"Echocardiography-guided left ventricular lead placement for cardiac resynchronization therapy: results of the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region trial","volume":"6","author":"Saba","year":"2013","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.hrthm.2023.10.003_bib29","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1093\/europace\/euab253","article-title":"Radial strain imaging-guided lead placement for improving response to cardiac resynchronization therapy in patients with ischaemic cardiomyopathy: the Raise CRT trial","volume":"24","author":"Glikson","year":"2022","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2023.10.003_bib30","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1111\/j.1540-8167.2011.02052.x","article-title":"Positioning of left ventricular pacing lead guided by intracardiac echocardiography with vector velocity imaging during cardiac resynchronization therapy procedure","volume":"22","author":"Bai","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib31","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1016\/j.jacep.2017.01.018","article-title":"Real-time X-MRI-guided left ventricular lead implantation for targeted delivery of cardiac resynchronization therapy","volume":"3","author":"Behar","year":"2017","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib32","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1007\/s10554-019-01574-0","article-title":"Multimodality imaging for real-time image-guided left ventricular lead placement during cardiac resynchronization therapy implantations","volume":"35","author":"Salden","year":"2019","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.hrthm.2023.10.003_bib33","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2021-054115","article-title":"Advanced image-supported lead placement in cardiac resynchronisation therapy: protocol for the multicentre, randomised controlled ADVISE trial and early economic evaluation","volume":"11","author":"Wouters","year":"2021","journal-title":"BMJ Open"},{"key":"10.1016\/j.hrthm.2023.10.003_bib34","doi-asserted-by":"crossref","first-page":"1364","DOI":"10.1016\/j.hrthm.2017.04.041","article-title":"Comprehensive use of cardiac computed tomography to guide left ventricular lead placement in cardiac resynchronization therapy","volume":"14","author":"Behar","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2023.10.003_bib35","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1111\/jce.14896","article-title":"Feasibility of intraprocedural integration of cardiac CT to guide left ventricular lead implantation for CRT upgrades","volume":"32","author":"Gould","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib36","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1002\/ejhf.605","article-title":"Cardiac resynchronization therapy guided by multimodality cardiac imaging","volume":"18","author":"Bertini","year":"2016","journal-title":"Eur J Heart Fail"},{"key":"10.1016\/j.hrthm.2023.10.003_bib37","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1016\/j.jacep.2020.05.011","article-title":"Cardiac resynchronization therapy guided by echocardiography, MRI, and CT imaging: a randomized controlled study","volume":"6","author":"Borgquist","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib38","doi-asserted-by":"crossref","first-page":"1365","DOI":"10.1002\/ejhf.530","article-title":"Multimodality imaging-guided left ventricular lead placement in cardiac resynchronization therapy: a randomized controlled trial","volume":"18","author":"Sommer","year":"2016","journal-title":"Eur J Heart Fail"},{"key":"10.1016\/j.hrthm.2023.10.003_bib39","doi-asserted-by":"crossref","first-page":"1369","DOI":"10.1093\/europace\/euz184","article-title":"Electrically vs. imaging-guided left ventricular lead placement in cardiac resynchronization therapy: a randomized controlled trial","volume":"21","author":"Stephansen","year":"2019","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2023.10.003_bib40","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.ijcard.2018.06.009","article-title":"Cardiac resynchronization therapy guided by cardiac magnetic resonance imaging: a prospective, single-centre randomized study (CMR-CRT)","volume":"270","author":"Ko\u010dkov\u00e1","year":"2018","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib41","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1016\/j.hrthm.2015.03.006","article-title":"In\u00a0vivo electromechanical assessment of heart failure patients with prolonged QRS duration","volume":"12","author":"Kroon","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2023.10.003_bib42","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1016\/j.jacep.2017.03.014","article-title":"Regional left ventricular electrical activation and peak contraction are closely related in candidates for cardiac resynchronization therapy","volume":"3","author":"Mafi-Rad","year":"2017","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2023.10.003_bib43","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1093\/europace\/euz346","article-title":"The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients","volume":"22","author":"Maffessanti","year":"2020","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2023.10.003_bib44","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1002\/ejhf.178","article-title":"Different regions of latest electrical activation during left bundle-branch block and right ventricular pacing in cardiac resynchronization therapy patients determined by coronary venous electro-anatomic mapping","volume":"16","author":"Mafi Rad","year":"2014","journal-title":"Eur J Heart Fail"},{"key":"10.1016\/j.hrthm.2023.10.003_bib45","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1007\/s12265-013-9457-0","article-title":"Further deterioration of LV ejection fraction and mechanical synchrony during RV apical pacing in patients with heart failure and LBBB","volume":"6","author":"Ludwig","year":"2013","journal-title":"J Cardiovasc Transl Res"},{"key":"10.1016\/j.hrthm.2023.10.003_bib46","first-page":"912","article-title":"Left univentricular pacing for cardiac resynchronization therapy","volume":"19","author":"Burri","year":"2017","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2023.10.003_bib47","doi-asserted-by":"crossref","unstructured":"Wilkoff BL, Filippatos G, Leclercq C, et\u00a0al. Adaptive versus conventional cardiac resynchronisation therapy in patients with heart failure (AdaptResponse): a global, prospective, randomised controlled trial [published online ahead of print September 30, 2023]. Lancet. doi:10.1016\/S0140-6736(23)00912-1.","DOI":"10.1016\/S0140-6736(23)00912-1"},{"key":"10.1016\/j.hrthm.2023.10.003_bib48","doi-asserted-by":"crossref","first-page":"1577","DOI":"10.1016\/j.hrthm.2021.05.006","article-title":"Gain in real-world cardiac resynchronization therapy efficacy with SyncAV dynamic optimization: heart failure hospitalizations and costs","volume":"18","author":"Varma","year":"2021","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2023.10.003_bib49","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1016\/j.hrthm.2015.03.006","article-title":"In vivo electromechanical assessment of heart failure patients with prolonged QRS duration","volume":"12","author":"Kroon","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2023.10.003_bib51","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0180637","article-title":"Evaluation of the use of unipolar voltage amplitudes for detection of myocardial scar assessed by cardiac magnetic resonance imaging in heart failure patients","volume":"12","author":"Nguy\u00ean","year":"2017","journal-title":"PLoS One"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527123027790?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527123027790?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T07:00:00Z","timestamp":1761548400000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527123027790"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":50,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["S1547527123027790"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2023.10.003","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Left ventricular lead placement in cardiac resynchronization therapy: Current data and potential explanations for the lack of benefit","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2023.10.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 Heart Rhythm Society.","name":"copyright","label":"Copyright"}]}}