{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T17:01:50Z","timestamp":1788195710860,"version":"build-2803163510"},"reference-count":30,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,4,2]],"date-time":"2024-04-02T00:00:00Z","timestamp":1712016000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","heartrhythmjournal.com","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2024,9]]},"DOI":"10.1016\/j.hrthm.2024.03.1816","type":"journal-article","created":{"date-parts":[[2024,4,2]],"date-time":"2024-04-02T16:30:46Z","timestamp":1712075446000},"page":"1695-1702","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Association of chronic kidney disease and end-stage renal disease with procedural complications and inpatient outcomes of leadless pacemaker implantations across the United States"],"prefix":"10.1016","volume":"21","author":[{"given":"Muhammad Zia","family":"Khan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6256-6825","authenticated-orcid":false,"given":"Amanda","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad Usman","family":"Khan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasar","family":"Sattar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Waleed","family":"Alruwaili","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karthik","family":"Gonuguntla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hafiz Muhammad","family":"Sohaib Hayat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melody","family":"Mendez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sameh","family":"Nassar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zain Ul","family":"Abideen Asad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siddharth","family":"Agarwal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sameer","family":"Raina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sudarshan","family":"Balla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bao","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dali","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas","family":"Darden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9804-898X","authenticated-orcid":false,"given":"Muhammad Bilal","family":"Munir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2024.03.1816_bib1","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1093\/europace\/euv202","volume":"17","author":"Boriani","year":"2015","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib2","doi-asserted-by":"crossref","first-page":"e05","DOI":"10.15420\/ecr.2021.52","article-title":"Arrhythmias in chronic kidney disease","volume":"17","author":"Akhtar","year":"2022","journal-title":"Eur Cardiol Rev"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib3","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1111\/sdi.12581","article-title":"Venous hemodialysis catheters and cardiac implantable electronic devices: avoiding a high-risk combination","volume":"30","author":"Saad","year":"2017","journal-title":"Semin Dial"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib4","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.pcad.2021.06.003","article-title":"Leadless pacemakers: a review of current data and future directions","volume":"66","author":"Middour","year":"2021","journal-title":"Prog Cardiovasc Dis"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib5","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.3390\/jcm10081745","article-title":"Cardiac implantable electronic devices in hemodialysis and chronic kidney disease patients\u2014an experience-based narrative review","volume":"10","author":"Nowak","year":"2021","journal-title":"J Clin Med"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib6","doi-asserted-by":"crossref","first-page":"161","DOI":"10.2174\/1573403X15666190118123754","article-title":"Implantable cardioverter-defibrillators in patients with ESRD: complications, management, and literature review","volume":"15","author":"Mehdi","year":"2019","journal-title":"Curr Cardiol Rev"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib7","doi-asserted-by":"crossref","first-page":"180","DOI":"10.14740\/jocmr4075","article-title":"Chronic kidney disease in patients undergoing cardiac device placement: results of a retrospective study","volume":"12","author":"Hossain","year":"2020","journal-title":"J Clin Med Res"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib8","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1111\/sdi.12073","article-title":"The impact of transvenous cardiac devices on vascular access patency in hemodialysis patients","volume":"26","author":"Tan","year":"2013","journal-title":"Semin Dial"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib9","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.117.005706","article-title":"Transvenous lead extraction in chronic kidney disease and dialysis patients with infected cardiac devices","volume":"11","author":"Barakat","year":"2018","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib10","article-title":"Impact of chronic kidney disease on short-term cardiac implantable electronic device related infection: a nationwide population-based cohort study","volume":"95","author":"Lin","year":"2016","journal-title":"Medicine (Baltimore)"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib11","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1111\/j.1540-8167.2011.02066.x","article-title":"End-stage renal disease predicts complications in pacemaker and ICD implants","volume":"22","author":"Tompkins","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib12","doi-asserted-by":"crossref","DOI":"10.1016\/j.cpcardiol.2020.100639","article-title":"Implantable cardioverter defibrillators and chronic kidney disease","volume":"46","author":"Kiage","year":"2021","journal-title":"Curr Probl Cardiol"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib13","doi-asserted-by":"crossref","first-page":"2115","DOI":"10.1093\/ndt\/gfw302","article-title":"Permanent cardiac pacing in patients with end-stage renal disease undergoing dialysis","volume":"31","author":"Wang","year":"2016","journal-title":"Nephrol Dial Transplant"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2014\/284172","article-title":"Mortality in patients on renal replacement therapy and permanent cardiac pacemakers","volume":"2014","author":"Vanerio","year":"2014","journal-title":"Int J Nephrol"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib15","doi-asserted-by":"crossref","first-page":"1565","DOI":"10.1016\/j.hrthm.2009.08.006","article-title":"Clinical characteristics and in-hospital outcome of patients with end-stage renal disease on dialysis referred for implantable cardioverter-defibrillator implantation","volume":"6","author":"Aggarwal","year":"2009","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib16","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1053\/j.ajkd.2007.02.272","article-title":"Increased complication rates of cardiac rhythm management devices in ESRD patients","volume":"49","author":"Dasgupta","year":"2007","journal-title":"Am J Kidney Dis"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib17","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1016\/j.hroo.2021.08.002","volume":"2","author":"Munir","year":"2021","journal-title":"Heart Rhythm O2"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib18","doi-asserted-by":"crossref","first-page":"2050","DOI":"10.1016\/j.jcin.2017.07.044","article-title":"Association of chronic kidney disease with in-hospital outcomes of transcatheter aortic valve replacement","volume":"10","author":"Gupta","year":"2017","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib19","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.117.005477","article-title":"Comparative outcomes of patients with advanced renal dysfunction undergoing transcatheter aortic valve replacement in the United States from 2011 to 2014","volume":"10","author":"Mohananey","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib22","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.jacep.2018.12.008","article-title":"Leadless pacemaker implantation in hemodialysis patients","volume":"5","author":"El-Chami","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib23","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad269","article-title":"Comparison of in-hospital outcomes and complications of leadless pacemaker and traditional transvenous pacemaker implantation","volume":"25","author":"Alhuarrat","year":"2023","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib24","doi-asserted-by":"crossref","first-page":"2165","DOI":"10.1007\/s10840-023-01550-8","article-title":"Comparative assessment of safety with leadless pacemakers compared to transvenous pacemakers: a systemic review and meta-analysis","volume":"66","author":"Shtembari","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib25","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1016\/j.hrthm.2022.03.1226","article-title":"Clinical outcomes and predictors of complications in patients undergoing leadless pacemaker implantation","volume":"19","author":"Haddadin","year":"2022","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib26","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1001\/jamacardio.2021.2621","article-title":"Contemporaneous comparison of outcomes among patients implanted with a leadless vs transvenous single-chamber ventricular pacemaker","volume":"6","author":"Piccini","year":"2021","journal-title":"JAMA Cardiol"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib27","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1016\/j.hrthm.2022.04.008","article-title":"Early trends in leadless pacemaker implantation: evaluating nationwide in-hospital outcomes","volume":"19","author":"Vincent","year":"2022","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib28","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1016\/j.hrthm.2023.05.031","article-title":"Five-year safety and efficacy of leadless pacemakers in a Dutch cohort","volume":"20","author":"Breeman","year":"2023","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib29","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.hrthm.2023.09.017","article-title":"Outcomes of patients implanted with an atrioventricular synchronous leadless ventricular pacemaker in the Medicare population","volume":"21","author":"Crossley","year":"2024","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib30","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1093\/europace\/euad016","article-title":"Two-year outcomes of leadless vs. transvenous single-chamber ventricular pacemaker in high-risk subgroups","volume":"25","author":"Boveda","year":"2023","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib31","article-title":"Abstract 14011: Micra AV leadless vs. dual-chamber transvenous pacing outcomes among patients with end-stage renal disease in the Medicare population","volume":"148","author":"Longacre","year":"2023","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2024.03.1816_bib32","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1111\/pace.12883","article-title":"The effect of chronic kidney disease on mortality with cardiac resynchronization therapy","volume":"39","author":"Daly","year":"2016","journal-title":"Pacing Clin Electrophysiol"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527124023117?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527124023117?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T08:13:45Z","timestamp":1724746425000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527124023117"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9]]},"references-count":30,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024,9]]}},"alternative-id":["S1547527124023117"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2024.03.1816","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Association of chronic kidney disease and end-stage renal disease with procedural complications and inpatient outcomes of leadless pacemaker implantations across the United States","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2024.03.1816","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Heart Rhythm Society.","name":"copyright","label":"Copyright"}]}}