{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:20:20Z","timestamp":1790727620194,"version":"4.1.0"},"reference-count":34,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","heartrhythmjournal.com","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2024,10]]},"DOI":"10.1016\/j.hrthm.2024.04.054","type":"journal-article","created":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T15:38:33Z","timestamp":1715960313000},"page":"1953-1961","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":27,"title":["Transvenous extraction of conduction system pacing leads: An international  ulticenter (TECSPAM) study"],"prefix":"10.1016","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2230-100X","authenticated-orcid":false,"given":"Pugazhendhi","family":"Vijayaraman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohan S.","family":"Trivedi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jayanthi N.","family":"Koneru","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parikshit S.","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"De Pooter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert D.","family":"Schaller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00d3scar","family":"Cano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachary I.","family":"Whinnett","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federico","family":"Migliore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shunmuga Sundaram","family":"Ponnusamy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jamario R.","family":"Skeete","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Zanon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frederic V.","family":"Heuverswyn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey","family":"Kolominsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raimondo","family":"Pittorru","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mishal","family":"Mumtaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth A.","family":"Ellenbogen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bengt","family":"Herweg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2024.04.054_bib1","doi-asserted-by":"crossref","first-page":"1589","DOI":"10.1007\/s10840-022-01417-4","article-title":"Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads","volume":"66","author":"Perino","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib2","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1016\/j.hrthm.2017.12.022","article-title":"Permanent His-bundle pacing: long-term lead performance and clinical outcomes","volume":"15","author":"Vijayaraman","year":"2018","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib3","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.1016\/j.jacc.2018.02.048","article-title":"Clinical outcomes of His bundle pacing compared to right ventricular pacing","volume":"71","author":"Abdelrahman","year":"2018","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib4","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.hrthm.2021.08.033","article-title":"Clinical outcomes of left bundle branch area pacing compared to right ventricular pacing: results from the Geisinger-Rush Conduction System Pacing Registry","volume":"19","author":"Sharma","year":"2022","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib5","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.120.018478","article-title":"Development of new-onset or progressive atrial fibrillation in patients with permanent His bundle pacing versus right ventricular pacing: results from the RUSH HBP Registry","volume":"9","author":"Ravi","year":"2020","journal-title":"J Am Heart Assoc"},{"key":"10.1016\/j.hrthm.2024.04.054_bib6","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.121.010710","article-title":"New-onset atrial fibrillation in left bundle branch area pacing compared with right ventricular pacing","volume":"15","author":"Ravi","year":"2022","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib7","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.hrthm.2017.10.014","article-title":"Permanent His-bundle pacing as an alternative to biventricular pacing for cardiac resynchronization therapy: a multicenter experience","volume":"15","author":"Sharma","year":"2018","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib8","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.hrthm.2022.04.023","article-title":"Clinical outcomes of conduction system pacing compared to biventricular pacing in patients requiring cardiac resynchronization therapy","volume":"19","author":"Vijayaraman","year":"2022","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib9","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.jacc.2023.05.006","article-title":"Comparison of left bundle branch area pacing and biventricular pacing in candidates for resynchronization therapy","volume":"82","author":"Vijayaraman","year":"2023","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib10","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1016\/j.hrthm.2019.05.009","article-title":"On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: a secondary analysis of the His-SYNC pilot trial","volume":"16","author":"Upadhyay","year":"2019","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib11","doi-asserted-by":"crossref","first-page":"2628","DOI":"10.1016\/j.jacep.2023.08.003","article-title":"His-Purkinje conduction system pacing optimized trial of cardiac resynchronization therapy vs biventricular pacing: HOT-CRT clinical trial","volume":"9","author":"Vijayaraman","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib12","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.jacc.2022.07.019","article-title":"Randomized trial of left bundle branch vs biventricular pacing for cardiac resynchronization therapy","volume":"80","author":"Wang","year":"2022","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib13","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1016\/j.jacep.2021.04.003","article-title":"A randomized trial of His pacing versus biventricular pacing in symptomatic HF patients with left bundle branch block (His-Alternative)","volume":"7","author":"Vinther","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib14","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1111\/jce.15558","article-title":"Initial experience of left bundle branch area pacing using stylet-driven pacing leads: a multicenter study","volume":"33","author":"De Pooter","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib15","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.hroo.2023.11.017","article-title":"Utility of a guiding catheter for conduction system pacing: an early multicenter experience","volume":"5","author":"De Pooter","year":"2023","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib16","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1016\/j.hrthm.2024.01.049","article-title":"Lead performance of stylet-driven leads in left bundle branch area pacing: results from a large single-center cohort and insights from in\u00a0vitro bench testing","volume":"21","author":"\u00d6zpak","year":"2024","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib17","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1016\/j.hroo.2023.11.014","article-title":"Acute performance of stylet driven leads for left bundle branch area pacing: a comparison with lumenless leads","volume":"4","author":"Cano","year":"2023","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib18","doi-asserted-by":"crossref","first-page":"e17","DOI":"10.1016\/j.hrthm.2023.03.1538","article-title":"2023 HRS\/APHRS\/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure","volume":"20","author":"Chung","year":"2023","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib19","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1016\/j.hrthm.2019.06.005","article-title":"Extraction of the permanent His bundle pacing lead: safety outcomes and feasibility of reimplantation","volume":"16","author":"Vijayaraman","year":"2019","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib20","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1016\/j.jacep.2020.04.005","article-title":"Extraction of left bundle branch pacing lead","volume":"6","author":"Vijayaraman","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib21","doi-asserted-by":"crossref","first-page":"2346","DOI":"10.1111\/jce.15155","article-title":"Late dislodgement of left bundle branch pacing lead and successful extraction","volume":"32","author":"Ponnusamy","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib22","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1007\/s10840-023-01590-0","article-title":"Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience","volume":"67","author":"Migliore","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib23","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.hrthm.2023.12.023","article-title":"Late distal conductor fracture of the lumenless pacing lead after left bundle branch area pacing","volume":"21","author":"Rangaswamy","year":"2024","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib24","doi-asserted-by":"crossref","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib25","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1016\/j.hrthm.2023.02.025","article-title":"Mechanics of lumenless pacing lead strength during extraction procedures based on laboratory bench testing","volume":"20","author":"Vatterott","year":"2023","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib26","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1111\/pace.12508","article-title":"Lumenless pacing leads: performance and extraction in pediatrics and congenital heart disease","volume":"38","author":"Garnreiter","year":"2015","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib27","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.hrcr.2022.10.007","article-title":"Lead-to-lead interaction leading to left bundle branch area pacing lead failure","volume":"9","author":"Mahajan","year":"2022","journal-title":"HeartRhythm Case Rep"},{"key":"10.1016\/j.hrthm.2024.04.054_bib28","doi-asserted-by":"crossref","first-page":"1412","DOI":"10.1016\/j.hrthm.2024.03.037","article-title":"A novel method to disengage trapped helix during left bundle branch pacing","volume":"21","author":"Seow","year":"2024","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib29","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.hrthm.2023.12.015","article-title":"Transvenous lead extraction safety and efficacy in infected and noninfected patients using mechanical-only tools: prospective registry from a high-volume center","volume":"21","author":"G\u0142adysz-Wa\u0144ha","year":"2024","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib30","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1093\/europace\/euaa350","article-title":"His bundle pacing capture threshold stability during long-term follow-up and correlation with lead slack","volume":"23","author":"Beer","year":"2021","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2024.04.054_bib31","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.hrthm.2020.12.031","article-title":"Intermediate-term performance and safety of His-bundle pacing leads: a single-center experience","volume":"18","author":"Teigeler","year":"2021","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2024.04.054_bib32","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1111\/jce.15843","article-title":"Clinical use conditions of lead deployment and simulated lead fracture rate in left bundle branch area pacing","volume":"34","author":"Zou","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.04.054_bib33","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.hrcr.2022.10.004","article-title":"Early sudden distal conductor fracture of a stylet-driven lead implanted for left bundle branch area pacing","volume":"9","author":"Thaler","year":"2022","journal-title":"HeartRhythm Case Rep"},{"key":"10.1016\/j.hrthm.2024.04.054_bib34","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.1111\/jce.15030","article-title":"Repositioning and extraction of stylet-driven pacing leads with extendable helix used for left bundle branch area pacing","volume":"32","author":"le Polain de Waroux","year":"2021","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527124023816?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527124023816?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,1,19]],"date-time":"2025-01-19T23:08:34Z","timestamp":1737328114000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527124023816"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":34,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["S1547527124023816"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2024.04.054","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Transvenous extraction of conduction system pacing leads: An international multicenter (TECSPAM) study","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2024.04.054","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Heart Rhythm Society. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}