{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,24]],"date-time":"2025-02-24T05:19:27Z","timestamp":1740374367485,"version":"3.37.3"},"reference-count":16,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100001316","name":"Abbott Laboratories","doi-asserted-by":"publisher","award":["NCT01555619"],"award-info":[{"award-number":["NCT01555619"]}],"id":[{"id":"10.13039\/100001316","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","heartrhythmjournal.com","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2025,2]]},"DOI":"10.1016\/j.hrthm.2024.07.006","type":"journal-article","created":{"date-parts":[[2024,7,5]],"date-time":"2024-07-05T02:02:42Z","timestamp":1720144962000},"page":"349-356","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Performance of the quadripolar CRT-D system: Five-year results from the Quadripolar Pacing Post-Approval Study"],"prefix":"10.1016","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6424-2071","authenticated-orcid":false,"given":"Raffaele","family":"Corbisiero","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Cao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Muller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kwangdeok","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Martin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2024.07.006_bib1","doi-asserted-by":"crossref","first-page":"1845","DOI":"10.1056\/NEJMoa013168","article-title":"Cardiac resynchronization in chronic heart failure","volume":"346","author":"Abraham","year":"2002","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2024.07.006_bib2","doi-asserted-by":"crossref","first-page":"2685","DOI":"10.1001\/jama.289.20.2685","article-title":"Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD trial","volume":"289","author":"Young","year":"2003","journal-title":"JAMA"},{"key":"10.1016\/j.hrthm.2024.07.006_bib3","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1161\/CIRCULATIONAHA.106.629261","article-title":"Effects of cardiac resynchronization therapy with or without a defibrillator on survival and hospitalizations in patients with New York Heart Association class IV heart failure","volume":"115","author":"Lindenfeld","year":"2007","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2024.07.006_bib4","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/j.ahj.2008.11.006","article-title":"Effects of cardiac resynchronization therapy on long-term quality of life: an analysis from the CArdiac Resynchronisation\u2013Heart Failure (CARE-HF) study","volume":"157","author":"Cleland","year":"2009","journal-title":"Am Heart J"},{"key":"10.1016\/j.hrthm.2024.07.006_bib5","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1111\/jce.12625","article-title":"Cardiac resynchronization therapy delivered via a multipolar left ventricular lead is associated with reduced mortality and elimination of phrenic nerve stimulation: long-term follow-up from a multicenter registry","volume":"26","author":"Behar","year":"2015","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.07.006_bib6","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1111\/jce.12065","article-title":"Postoperative performance of the Quartet left ventricular heart lead","volume":"24","author":"Tomassoni","year":"2013","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.07.006_bib7","article-title":"Assessing the cost burden of United States FDA-mandated post-approval studies for medical devices","volume":"2016","author":"Wimmer","year":"2016","journal-title":"J Health Care Finance"},{"key":"10.1016\/j.hrthm.2024.07.006_bib8","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.ahj.2010.11.011","article-title":"Clinical and echocardiographic predictors of nonresponse to cardiac resynchronization therapy","volume":"161","author":"Shanks","year":"2011","journal-title":"Am Heart J"},{"key":"10.1016\/j.hrthm.2024.07.006_bib9","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1093\/europace\/eus237","article-title":"Occurrence of phrenic nerve stimulation in cardiac resynchronization therapy patients: the role of left ventricular lead type and placement site","volume":"15","author":"Biffi","year":"2013","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2024.07.006_bib10","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1093\/europace\/euu290","article-title":"Hospitalization rates and associated cost analysis of cardiac resynchronization therapy with an implantable defibrillator and quadripolar vs. bipolar left ventricular leads: a comparative effectiveness study","volume":"17","author":"Forleo","year":"2015","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2024.07.006_bib11","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1111\/pace.12923","article-title":"Less with more: hospitalization cost and event rates with Quadripolar versus bipolar CRT-D system","volume":"39","author":"Corbisiero","year":"2016","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.07.006_bib12","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.jchf.2021.10.012","article-title":"Complications and mortality following CRT-D versus ICD implants in older Medicare beneficiaries with heart failure","volume":"10","author":"Zeitler","year":"2022","journal-title":"JACC Heart Fail"},{"key":"10.1016\/j.hrthm.2024.07.006_bib13","doi-asserted-by":"crossref","first-page":"2438","DOI":"10.1002\/ehf2.13357","article-title":"Five-year survival and use of hospital services following ICD and CRT implantation: comparing real-world data with RCTs","volume":"8","author":"Bottle","year":"2021","journal-title":"ESC Heart Fail"},{"key":"10.1016\/j.hrthm.2024.07.006_bib14","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1016\/j.jacep.2017.02.021","article-title":"Sex-specific response to cardiac resynchronization therapy: effect of left ventricular size and QRS duration in left bundle branch block","volume":"3","author":"Varma","year":"2017","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2024.07.006_bib15","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.cardfail.2012.09.003","article-title":"Comorbidity significantly affects clinical outcome after cardiac resynchronization therapy regardless of ventricular remodeling","volume":"18","author":"Verbrugge","year":"2012","journal-title":"J Card Fail"},{"key":"10.1016\/j.hrthm.2024.07.006_bib16","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.jacep.2016.02.007","article-title":"Reduced mortality associated with quadripolar compared to bipolar left ventricular leads in cardiac resynchronization therapy","volume":"2","author":"Turakhia","year":"2016","journal-title":"JACC Clin Electrophysiol"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527124028777?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527124028777?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,2,23]],"date-time":"2025-02-23T10:12:48Z","timestamp":1740305568000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527124028777"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":16,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["S1547527124028777"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2024.07.006","relation":{},"ISSN":["1547-5271"],"issn-type":[{"type":"print","value":"1547-5271"}],"subject":[],"published":{"date-parts":[[2025,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Performance of the quadripolar CRT-D system: Five-year results from the Quadripolar Pacing Post-Approval Study","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2024.07.006","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Heart Rhythm Society. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}