{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T23:38:17Z","timestamp":1793230697959,"version":"4.5.0"},"reference-count":27,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2025,7]]},"DOI":"10.1016\/j.hrthm.2025.01.022","type":"journal-article","created":{"date-parts":[[2025,1,24]],"date-time":"2025-01-24T19:15:27Z","timestamp":1737746127000},"page":"e51-e59","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":31,"title":["Clinical importance of tissue proximity indication during pulsed field ablation for atrial fibrillation: Insights from initial experience"],"prefix":"10.1016","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-3916-4033","authenticated-orcid":false,"given":"Yuji","family":"Saito","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichi","family":"Nagashima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryuta","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuji","family":"Wakamatsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoto","family":"Otsuka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shu","family":"Hirata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moyuru","family":"Hirata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masanaru","family":"Sawada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sayaka","family":"Kurokawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2960-4241","authenticated-orcid":false,"given":"Yasuo","family":"Okumura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2025.01.022_bib1","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1093\/eurheartj\/ehaa612","volume":"42","author":"Hindricks","year":"2021","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2025.01.022_bib2","doi-asserted-by":"crossref","DOI":"10.1161\/CIR.0000000000000665","volume":"140","author":"January","year":"2019","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2025.01.022_bib3","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1016\/j.jacep.2018.04.005","article-title":"Ablation of atrial fibrillation with pulsed electric fields: an ultra-rapid, tissue-selective modality for cardiac ablation","volume":"4","author":"Reddy","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib4","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/j.jacc.2019.04.021","article-title":"Pulsed field ablation for pulmonary vein isolation in atrial fibrillation","volume":"74","author":"Reddy","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib5","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.120.008718","article-title":"Lattice-tip focal ablation catheter that toggles between radiofrequency and pulsed field energy to treat atrial fibrillation: a first-in-human trial","volume":"13","author":"Reddy","year":"2020","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib6","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.122.011780","article-title":"Paroxysmal atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter integrated with a 3-dimensional mapping system: 1-year outcomes of the multicenter inspIRE study","volume":"16","author":"Duytschaever","year":"2023","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib7","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1161\/CIRCULATIONAHA.123.064959","article-title":"Safety and effectiveness of pulsed field ablation to treat atrial fibrillation: one-year outcomes from the MANIFEST-PF registry","volume":"148","author":"Turagam","year":"2023","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2025.01.022_bib8","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1016\/j.jacep.2023.01.009","article-title":"PV isolation using a spherical array PFA catheter: application repetition and lesion durability (PULSE-EU study)","volume":"9","author":"Turagam","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib9","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1161\/CIRCULATIONAHA.123.063988","article-title":"Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial","volume":"147","author":"Verma","year":"2023","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2025.01.022_bib10","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","article-title":"Pulsed field or conventional thermal ablation for paroxysmal atrial fibrillation","volume":"389","author":"Reddy","year":"2023","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2025.01.022_bib11","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.123.012667","article-title":"Predictors of success for pulmonary vein isolation with Pulsed-field Ablation using a variable-loop catheter with 3D mapping integration: complete 12-month outcomes from inspIRE","volume":"17","author":"De Potter","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib12","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1007\/s10840-023-01608-7","article-title":"Pulmonary vein isolation durability and lesion regression in patients with recurrent arrhythmia after pulsed-field ablation","volume":"67","author":"Kueffer","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib13","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1007\/s10840-017-0252-8","article-title":"High-voltage zones within the pulmonary vein antra: Major determinants of acute pulmonary vein reconnections after atrial fibrillation ablation","volume":"49","author":"Nagashima","year":"2017","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib14","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s10840-018-0501-5","article-title":"The modified ablation index: a novel determinant of acute pulmonary vein reconnections after pulmonary vein isolation","volume":"55","author":"Wakamatsu","year":"2019","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib15","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1002\/joa3.13009","article-title":"Where is the gap after a 90 W\/4 s very-high-power short-duration ablation of atrial fibrillation? Association with the left atrial-pulmonary vein voltage and wall thickness","volume":"40","author":"Hirata","year":"2024","journal-title":"J Arrhythm"},{"key":"10.1016\/j.hrthm.2025.01.022_bib16","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1093\/europace\/euab216","article-title":"Personalized paroxysmal atrial fibrillation ablation by tailoring ablation index to the left atrial wall thickness: the \u201cAblate by-LAW\u201d single-centre study-a pilot study","volume":"24","author":"Teres","year":"2022","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2025.01.022_bib17","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad118","article-title":"Personalized pulmonary vein antrum isolation guided by left atrial wall thickness for persistent atrial fibrillation","volume":"25","author":"Falasconi","year":"2023","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2025.01.022_bib18","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1111\/jce.15813","article-title":"Effect of contact force on pulsed field ablation lesions in porcine cardiac tissue","volume":"34","author":"Mattison","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib19","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.122.011110","article-title":"Effects of electrode-tissue proximity on cardiac lesion formation using pulsed field ablation","volume":"15","author":"Howard","year":"2022","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib20","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.123.012026","article-title":"Effects of contact force on lesion size during pulsed field catheter ablation: histochemical characterization of ventricular lesion boundaries","volume":"17","author":"Nakagawa","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib21","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.121.010661","article-title":"Time course of irreversible electroporation lesion development through short- and long-term follow-up in pulsed-field ablation-treated hearts","volume":"15","author":"Grimaldi","year":"2022","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib22","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.1111\/jce.15522","article-title":"In vivo porcine characterization of atrial lesion safety and efficacy utilizing a circular pulsed-field ablation catheter including assessment of collateral damage to adjacent tissue in supratherapeutic ablation applications","volume":"33","author":"Hsu","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib23","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.120.009229","article-title":"Circular multielectrode pulsed field ablation catheter lasso pulsed field ablation: lesion characteristics, durability, and effect on neighboring structures","volume":"14","author":"Yavin","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib24","doi-asserted-by":"crossref","first-page":"1817","DOI":"10.1111\/jce.16366","article-title":"VARIPULSE: a step-by-step guide to pulmonary vein isolation","volume":"35","author":"Nair","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.022_bib25","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1016\/j.hrthm.2024.09.061","article-title":"In vivo assessment of catheter-tissue contact using tissue proximity indication and its impact on cardiac lesion formation in pulsed field ablation","volume":"22","author":"Okumura","year":"2025","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2025.01.022_bib26","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.hroo.2024.04.012","article-title":"Pulsed-field ablation versus thermal ablation for atrial fibrillation: a meta-analysis","volume":"5","author":"de Campos","year":"2024","journal-title":"Heart Rhythm O2"},{"key":"10.1016\/j.hrthm.2025.01.022_bib27","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad335","article-title":"Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review","volume":"25","author":"Serban","year":"2023","journal-title":"Europace"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527125000918?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527125000918?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T08:23:31Z","timestamp":1774254211000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527125000918"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":27,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["S1547527125000918"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2025.01.022","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2025,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Clinical importance of tissue proximity indication during pulsed field ablation for atrial fibrillation: Insights from initial experience","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2025.01.022","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Heart Rhythm Society. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}