{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T08:46:10Z","timestamp":1767343570760,"version":"3.48.0"},"reference-count":20,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2026,1]]},"DOI":"10.1016\/j.hrthm.2025.01.036","type":"journal-article","created":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T13:28:59Z","timestamp":1738330139000},"page":"194-202","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["A leadless pericardial pacemaker"],"prefix":"10.1016","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6415-3685","authenticated-orcid":false,"given":"Yaniv","family":"Bar-Cohen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael J.","family":"Silka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Allison C.","family":"Hill","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Shwayder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jay D.","family":"Pruetz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lynlee","family":"Stevey-Rindenow","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raymond","family":"Peck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel","family":"Kohan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerald E.","family":"Loeb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2025.01.036_bib1","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1016\/j.hrthm.2011.12.014","article-title":"Incidence and predictors of short- and long- term complications in pacemaker therapy: the FOLLOWPACE study","volume":"9","author":"Udo","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2025.01.036_bib2","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.hrthm.2006.10.009","article-title":"Clinical experience with pacemaker pulse generators and transvenous leads: an 8-year prospective multicenter study","volume":"4","author":"Hauser","year":"2007","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2025.01.036_bib3","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1056\/NEJMoa1511643","article-title":"A leadless intracardiac transcatheter pacing system","volume":"374","author":"Reynolds","year":"2016","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2025.01.036_bib4","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s10439-012-0631-3","article-title":"Design and testing of a percutaneously implantable fetal pacemaker","volume":"41","author":"Loeb","year":"2013","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.hrthm.2025.01.036_bib5","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1016\/j.hrthm.2015.03.022","article-title":"Preclinical testing and optimization of a novel fetal micropacemaker","volume":"12","author":"Bar-Cohen","year":"2015","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2025.01.036_bib6","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.118.006307","article-title":"Minimally invasive implantation of a micropacemaker into the pericardial space","volume":"11","author":"Bar-Cohen","year":"2018","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.036_bib7","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1109\/TNSRE.2017.2679077","article-title":"Neurostimulation strategy for stress urinary incontinence","volume":"25","author":"Huang","year":"2017","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"10.1016\/j.hrthm.2025.01.036_bib8","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.hroo.2023.05.004","article-title":"Design and rationale of the MODULAR ATP global clinical trial: a novel intercommunicative leadless pacing system and the subcutaneous implantable cardioverter-defibrillator","volume":"4","author":"Lloyd","year":"2023","journal-title":"Heart Rhythm O2"},{"key":"10.1016\/j.hrthm.2025.01.036_bib9","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1111\/j.1540-8159.1996.tb03407.x","article-title":"The steroid-eluting electrode: a 10-year experience","volume":"19","author":"Mond","year":"1996","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.036_bib10","doi-asserted-by":"crossref","first-page":"1467","DOI":"10.1046\/j.1460-9592.2003.t01-1-00212.x","article-title":"Chronic performance of steroid-eluting epicardial leads in a growing pediatric population: a 10-year comparison","volume":"26","author":"Horenstein","year":"2003","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.036_bib11","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1161\/CIRCULATIONAHA.112.115428","article-title":"Permanent cardiac pacing in children: choosing the optimal pacing site: a multicenter study","volume":"127","author":"Janou\u0161ek","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2025.01.036_bib12","doi-asserted-by":"crossref","first-page":"2360","DOI":"10.1056\/NEJMoa2300080","article-title":"A dual-chamber leadless pacemaker","volume":"388","author":"Knops","year":"2023","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2025.01.036_bib13","doi-asserted-by":"crossref","first-page":"2210","DOI":"10.1016\/j.athoracsur.2013.07.057","article-title":"Minimally invasive resynchronization pacemaker: a pediatric animal model","volume":"96","author":"Jordan","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.hrthm.2025.01.036_bib14","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1161\/CIRCEP.114.002076","article-title":"Acute and chronic performance evaluation of a novel epicardial pacing lead placed by percutaneous subxiphoid approach in a canine model","volume":"8","author":"John","year":"2015","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.036_bib15","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1111\/jce.13263","article-title":"Single-incision percutaneous pericardial ICD lead placement in a piglet model","volume":"28","author":"Clark","year":"2017","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.036_bib16","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1016\/j.hrthm.2015.12.015","article-title":"Minimally invasive percutaneous pericardial ICD placement in an infant piglet model: head-to-head comparison with an open surgical thoracotomy approach","volume":"13","author":"Clark","year":"2016","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2025.01.036_bib17","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1111\/pace.13843","article-title":"Percutaneous epicardial placement of a prototype miniature pacemaker under direct visualization: an infant porcine chronic survival study","volume":"43","author":"Kumthekar","year":"2020","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.036_bib18","doi-asserted-by":"crossref","first-page":"1452","DOI":"10.1111\/jce.15926","article-title":"Percutaneous epicardial pacing in infants using direct visualization: a feasibility animal study","volume":"34","author":"Kumthekar","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2025.01.036_bib19","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1016\/j.hrthm.2017.11.030","article-title":"Feasibility of extravascular pacing with a novel substernal electrode configuration: the Substernal Pacing Acute Clinical Evaluation study","volume":"15","author":"Sholevar","year":"2018","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2025.01.036_bib20","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1016\/j.jacep.2024.02.004","article-title":"Percutaneous transpericardial permanent pacing in a woman with fontan circulation","volume":"10","author":"Lloyd","year":"2024","journal-title":"JACC Clin Electrophysiol"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527125001067?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527125001067?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T08:41:53Z","timestamp":1767343313000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527125001067"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["S1547527125001067"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2025.01.036","relation":{},"ISSN":["1547-5271"],"issn-type":[{"type":"print","value":"1547-5271"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A leadless pericardial pacemaker","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2025.01.036","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Heart Rhythm Society. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}