{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T09:10:33Z","timestamp":1790327433850,"version":"4.1.0"},"reference-count":33,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T00:00:00Z","timestamp":1778716800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster Inc","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004331","name":"Johnson and Johnson","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004331","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.hrthm.2026.05.016","type":"journal-article","created":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T02:48:24Z","timestamp":1778813304000},"page":"2123-2131","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Principles guiding PFA cardiac catheter and sheath management from preclinical assessment of microbubble formation and air intrusion models"],"prefix":"10.1016","volume":"23","author":[{"given":"Xiao-dong","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6355-8843","authenticated-orcid":false,"given":"Fengwei","family":"Zou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tara","family":"Gomez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Byun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacopo","family":"Marazzato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Schiavone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanghamitra","family":"Mohanty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincenzo Mirco","family":"La Fazia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jishu","family":"Motta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristian Zamora","family":"Rosales","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shubhi","family":"Pandey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lowell","family":"Safren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuval","family":"Shafir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vito","family":"Grupposo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Domingo","family":"Ynoa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aung","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dhanunjaya","family":"Lakkireddy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Natale","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nils","family":"Guttenplan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6508-4047","authenticated-orcid":false,"given":"Luigi","family":"Di Biase","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2026.05.016_bib1","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.hrthm.2025.04.008","article-title":"Incidence of silent cerebral events detected by MRI in patients with atrial fibrillation undergoing pulsed field ablation vs thermal ablation: a systematic review and network meta-analysis","volume":"23","author":"Hu","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.05.016_bib2","doi-asserted-by":"crossref","DOI":"10.1002\/hsr2.70439","article-title":"Pulsed field ablation: a systematic review","volume":"8","author":"Htay","year":"2025","journal-title":"Health Sci Rep"},{"key":"10.1016\/j.hrthm.2026.05.016_bib3","first-page":"996","article-title":"Silent cerebral events after atrial fibrillation ablation \u2013 overview and current data","volume":"6","author":"Deneke","year":"2014","journal-title":"J Atr Fibrillation"},{"key":"10.1016\/j.hrthm.2026.05.016_bib4","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.115.003226","article-title":"Effect of left atrial ablation process and strategy on microemboli formation during irrigated radiofrequency catheter ablation in an in vivo model","volume":"9","author":"Takami","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib5","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.hrthm.2018.07.038","article-title":"Techniques for reducing air bubble intrusion into the left atrium during radiofrequency catheter and cryoballoon ablation procedures: an ex vivo study with a high-resolution camera","volume":"16","author":"Takami","year":"2019","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.05.016_bib6","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1046\/j.1540-8167.2004.03401.x","article-title":"High-flow perfusion of sheaths for prevention of thromboembolic complications during complex catheter ablation in the left atrium","volume":"15","author":"Cauchemez","year":"2004","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib7","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/S0972-6292(16)30795-1","article-title":"Exchanging catheters over a single transseptal sheath during left atrial ablation is associated with a higher risk for silent cerebral events","volume":"14","author":"Deneke","year":"2014","journal-title":"Indian Pacing Electrophysiol J"},{"key":"10.1016\/j.hrthm.2026.05.016_bib8","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad151","article-title":"Silent cerebral lesions following catheter ablation for atrial fibrillation: a state-of-the-art review","volume":"25","author":"Calvert","year":"2023","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.05.016_bib9","doi-asserted-by":"crossref","first-page":"2071","DOI":"10.1111\/jce.14091","article-title":"In vitro analysis of the origin and characteristics of gaseous microemboli during catheter electroporation ablation","volume":"30","author":"Van Es","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib10","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1016\/j.hrthm.2021.02.015","article-title":"Absence of (sub-)acute cerebral events or lesions after electroporation ablation in the left-sided canine heart","volume":"18","author":"Neven","year":"2021","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.05.016_bib11","doi-asserted-by":"crossref","first-page":"1813","DOI":"10.1016\/j.hrthm.2022.06.018","article-title":"Cerebral safety after pulsed field ablation for paroxysmal atrial fibrillation","volume":"19","author":"Reinsch","year":"2022","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.05.016_bib12","article-title":"Size distribution of air bubbles entering the brain during cardiac surgery","volume":"10","author":"Chung","year":"2015","journal-title":"PLoS One"},{"key":"10.1016\/j.hrthm.2026.05.016_bib13","doi-asserted-by":"crossref","first-page":"2521","DOI":"10.1016\/j.hrthm.2024.05.050","article-title":"Potential microemboli formation risk and its management during the heated saline\u2013enhanced radiofrequency needle-tip catheter ablation","volume":"21","author":"Suzuki","year":"2024","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.05.016_bib14","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1093\/europace\/euaa243","article-title":"In vivo analysis of the origin and characteristics of gaseous microemboli during catheter-mediated irreversible electroporation","volume":"23","author":"Groen","year":"2021","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.05.016_bib15","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1161\/CIRCEP.111.973453","article-title":"Microembolism and catheter ablation I: a comparison of irrigated radiofrequency and multielectrode-phased radiofrequency catheter ablation of pulmonary vein ostia","volume":"6","author":"Haines","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib16","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1093\/europace\/eur314","article-title":"Clinical characteristics of massive air embolism complicating left atrial ablation of atrial fibrillation: lessons from five cases","volume":"14","author":"Kuwahara","year":"2012","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.05.016_bib17","doi-asserted-by":"crossref","first-page":"e276","DOI":"10.1016\/j.hrthm.2025.09.040","article-title":"Incidence and clinical implications of microbubble formation during pulsed field ablation","volume":"23","author":"Yano","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.05.016_bib18","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1111\/jce.14800","article-title":"Incidence and characteristics of silent cerebral embolisms after radiofrequency-based atrial fibrillation ablation: a propensity score-matched analysis between different mapping catheters and indices for guiding ablation","volume":"32","author":"Nakamura","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib19","doi-asserted-by":"crossref","first-page":"3231","DOI":"10.1111\/jce.70129","article-title":"An ex vivo evaluation of air intrusion into pulsed field ablation sheaths during ablation and mapping catheter insertion","volume":"36","author":"Gier","year":"2025","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib20","doi-asserted-by":"crossref","first-page":"2944","DOI":"10.1111\/jce.14208","article-title":"Prevention of serious air embolism during cryoballoon ablation; risk assessment of air intrusion into the sheath by catheter selection and change in intrathoracic pressure: an ex vivo study","volume":"30","author":"Tsukahara","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib21","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1016\/j.hrthm.2026.01.035","article-title":"Timing and characteristics of carotid microembolic signals during pentaspline pulsed field ablation","volume":"23","author":"Takami","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.05.016_bib22","doi-asserted-by":"crossref","first-page":"2918","DOI":"10.1378\/chest.128.4.2918","article-title":"Microbubbles: pathophysiology and clinical implications","volume":"128","author":"Barak","year":"2005","journal-title":"Chest"},{"key":"10.1016\/j.hrthm.2026.05.016_bib23","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1016\/j.jacep.2020.07.012","article-title":"Clinically manifesting air embolisms in cryoballoon ablation: can novel water buckets reduce the risk?","volume":"6","author":"Miyazaki","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib24","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1186\/1749-8090-8-198","article-title":"Impact of bubble size in a rat model of cerebral air microembolization","volume":"8","author":"Juenemann","year":"2013","journal-title":"J Cardiothorac Surg"},{"key":"10.1016\/j.hrthm.2026.05.016_bib25","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.hrthm.2025.06.046","article-title":"Real-time detection of microembolic signals using carotid echocardiography: a comparative study of 3 pulsed-field systems","volume":"23","author":"Shiomi","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.05.016_bib26","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.125.013719","article-title":"Different incidence and size of silent strokes after pulsed field ablation with circular shaped ablation catheters","volume":"18","author":"Miyazaki","year":"2025","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib27","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.122.011780","article-title":"Paroxysmal atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter integrated with a 3-dimensional mapping system: 1-year outcomes of the multicenter inspIRE study","volume":"16","author":"Duytschaever","year":"2023","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib28","doi-asserted-by":"crossref","first-page":"3288","DOI":"10.1111\/jce.70140","article-title":"Comparison of cerebral micro-embolization detected by transcranial Doppler examination between radiofrequency ablation and pulsed field ablation for atrial fibrillation","volume":"36","author":"Schreiber","year":"2025","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib29","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1111\/jce.70218","article-title":"Difference in cerebral microembolization with multielectrode pentaspline or variable-loop circular PFA systems","volume":"37","author":"Pagnoni","year":"2026","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib30","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.123.012667","article-title":"Predictors of success for pulmonary vein isolation with pulsed-field ablation using a variable-loop catheter with 3D mapping integration: complete 12-month outcomes from inspIRE","volume":"17","author":"De Potter","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.05.016_bib31","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1161\/CIRCULATIONAHA.124.070333","article-title":"Pulsed field ablation to treat paroxysmal atrial fibrillation: safety and effectiveness in the AdmIRE pivotal trial","volume":"150","author":"Reddy","year":"2024","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.05.016_bib32","article-title":"Evaluating safety profile and learning curve with a pulsed field ablation variable loop circular catheter in procedures for AF: observations from a prospective, multicenter, postmarket clinical trial","author":"Bessiere","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.05.016_bib33","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacep.2026.01.025","article-title":"Impact of lesion delivery and irrigation rates on neurovascular events with PFA for atrial fibrillation","author":"Mansour","year":"2026","journal-title":"JACC Clin Electrophysiol"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126023714?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126023714?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T08:39:10Z","timestamp":1790325550000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527126023714"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":33,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["S1547527126023714"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.05.016","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Principles guiding PFA cardiac catheter and sheath management from preclinical assessment of microbubble formation and air intrusion models","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.05.016","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Heart Rhythm Society.","name":"copyright","label":"Copyright"}]}}