{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T04:02:30Z","timestamp":1791345750056,"version":"4.3.1"},"reference-count":24,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1016\/j.hrthm.2026.07.032","type":"journal-article","created":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T12:27:09Z","timestamp":1785500829000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Real-world adverse events of pulsed field ablation for atrial fibrillation: A comprehensive analysis of the Food and Drug Administration Manufacturer and User Facility Device Experience database"],"prefix":"10.1016","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-1025-1068","authenticated-orcid":false,"given":"Bara M.","family":"Hammadeh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Layan","family":"Aldib","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhiram","family":"Challa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deitrich","family":"Gerlt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Al Mubaid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Utkarsh","family":"Kohli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2026.07.032_bib1","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1093\/eurheartj\/ehaa612","article-title":"2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"42","author":"Hindricks","year":"2021","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2026.07.032_bib2","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1001\/jama.2019.0693","article-title":"Effect of catheter ablation vs antiarrhythmic drug therapy on mortality, stroke, bleeding, and cardiac arrest among patients with atrial fibrillation","volume":"321","author":"Packer","year":"2019","journal-title":"JAMA"},{"key":"10.1016\/j.hrthm.2026.07.032_bib3","doi-asserted-by":"crossref","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","article-title":"HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"14","author":"Calkins","year":"2017","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.07.032_bib4","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1016\/j.jacep.2018.04.005","article-title":"Ablation of atrial fibrillation with pulsed electric fields","volume":"4","author":"Reddy","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.07.032_bib5","doi-asserted-by":"crossref","first-page":"2020","DOI":"10.1038\/s41591-024-03114-3","article-title":"Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study","volume":"30","author":"Ekanem","year":"2024","journal-title":"Nat Med"},{"key":"10.1016\/j.hrthm.2026.07.032_bib6","series-title":"Manufacturer and User Facility Device Experience","year":"2024"},{"key":"10.1016\/j.hrthm.2026.07.032_bib7","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1161\/CIRCULATIONAHA.123.064959","article-title":"Safety and effectiveness of pulsed field ablation to treat atrial fibrillation: one-year outcomes from the MANIFEST-PF registry","volume":"148","author":"Turagam","year":"2023","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.07.032_bib8","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1002\/pds.677","article-title":"Use of proportional reporting ratios (PRRs) for signal generation from spontaneous adverse drug reaction reports","volume":"10","author":"Evans","year":"2001","journal-title":"Pharmacoepidemiol Drug Saf"},{"key":"10.1016\/j.hrthm.2026.07.032_bib9","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1002\/pds.1001","article-title":"The reporting odds ratio and its advantages over the proportional reporting ratio","volume":"13","author":"Rothman","year":"2004","journal-title":"Pharmacoepidemiol Drug Saf"},{"key":"10.1016\/j.hrthm.2026.07.032_bib10","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","article-title":"Pulsed field or conventional thermal ablation for paroxysmal atrial fibrillation","volume":"389","author":"Reddy","year":"2023","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2026.07.032_bib11","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1161\/CIRCULATIONAHA.123.063988","article-title":"Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial","volume":"147","author":"Verma","year":"2023","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.07.032_bib12","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1093\/europace\/euac050","article-title":"Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF)","volume":"24","author":"Ekanem","year":"2022","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.07.032_bib13","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/j.jacc.2025.10.051","article-title":"Multicenter study on the safety of pulsed field ablation in over 40,000 patients","volume":"87","author":"Turagam","year":"2026","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2026.07.032_bib14","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1161\/CIRCULATIONAHA.124.070333","article-title":"Pulsed field ablation to treat paroxysmal atrial fibrillation: safety and effectiveness in the AdmIRE pivotal trial","volume":"150","author":"Reddy","year":"2024","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.07.032_bib16","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1111\/pace.70035","article-title":"Microbubble formation and hemolysis in pulsed field ablation for treating arrhythmia: risks, mechanisms, and prevention","volume":"49","author":"Ranjbartehrani","year":"2026","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.07.032_bib17","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1093\/europace\/euab090","article-title":"Pulsed field ablation selectively spares the oesophagus during pulmonary vein isolation for atrial fibrillation","volume":"23","author":"Cochet","year":"2021","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.07.032_bib18","doi-asserted-by":"crossref","first-page":"1808","DOI":"10.1161\/CIRCULATIONAHA.122.061497","article-title":"Coronary arterial spasm during pulsed field ablation to treat atrial fibrillation","volume":"146","author":"Reddy","year":"2022","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.07.032_bib19","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.120.008718","article-title":"Lattice-tip focal ablation catheter that toggles between radio frequency and pulsed field energy to treat atrial fibrillation","volume":"13","author":"Reddy","year":"2020","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.07.032_bib20","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1161\/CIRCEP.109.859116","article-title":"Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation","volume":"3","author":"Cappato","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.07.032_bib21","doi-asserted-by":"crossref","first-page":"2104","DOI":"10.1161\/CIRCULATIONAHA.113.003862","article-title":"In-hospital complications associated with catheter ablation of atrial fibrillation in the United States between 2000 and 2010","volume":"128","author":"Deshmukh","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.07.032_bib22","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1056\/NEJMp1712001","article-title":"Medical devices in the real world","volume":"378","author":"Resnic","year":"2018","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2026.07.032_bib23","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad185","article-title":"European real-world outcomes with Pulsed field ablatiOn in patients with symptomatic atrial fibrillation: lessons from the multi-centre EU-PORIA registry","volume":"25","author":"Schmidt","year":"2023","journal-title":"Europace"},{"issue":"suppl 3","key":"10.1016\/j.hrthm.2026.07.032_bib24","article-title":"Asymptomatic brain injury: a common finding after pulsed field ablation of uncertain significance\u2014a systematic review and meta-analysis","volume":"152","author":"Rodriguez-Riascos","year":"2025","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.07.032_bib25","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1016\/j.hrthm.2009.02.024","article-title":"Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure","volume":"6","author":"Hauser","year":"2009","journal-title":"Heart Rhythm"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126026135?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126026135?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T09:28:50Z","timestamp":1787390930000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527126026135"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":24,"alternative-id":["S1547527126026135"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.07.032","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Real-world adverse events of pulsed field ablation for atrial fibrillation: A comprehensive analysis of the Food and Drug Administration Manufacturer and User Facility Device Experience database","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.07.032","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Heart Rhythm Society. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}