{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T22:01:40Z","timestamp":1790892100256,"version":"4.1.0"},"reference-count":91,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100008170","name":"Minneapolis Heart Institute","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008170","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.hrthm.2026.08.010","type":"journal-article","created":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T16:01:20Z","timestamp":1786723280000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Tricuspid regurgitation and leadless pacemakers: A state-of-the-art review"],"prefix":"10.1016","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-2499-5570","authenticated-orcid":false,"given":"Kerollos","family":"Abdelsayed","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay","family":"Sengupta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo\u00e3o L.","family":"Cavalcante","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maurice","family":"Enriquez-Sarano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vinayak","family":"Bapat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Downey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dawn","family":"Witt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Bahbah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tesfatsiyon","family":"Ergando","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Tsunamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amr","family":"Idris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathew","family":"Olson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstantinos","family":"Voudris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edwin","family":"Zishiri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Zakaib","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JoEllyn C.","family":"Moore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott","family":"Sharkey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nadira","family":"Hamid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2026.08.010_bib1","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.amjcard.2023.09.064","article-title":"Incidence and prognostic implications of cardiac-implantable device-associated tricuspid regurgitation: a meta-analysis and meta-regression analysis","volume":"209","author":"Safiriyu","year":"2023","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib2","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1016\/j.jcin.2025.02.010","article-title":"Lead-related tricuspid regurgitation: novel insights through the lens of computed tomography","volume":"18","author":"Margonato","year":"2025","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2026.08.010_bib3","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.117.005043","article-title":"Mechanism and implications of the tricuspid regurgitation","volume":"10","author":"Mangieri","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2026.08.010_bib4","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.118.007124","article-title":"Impact of leadless pacemaker therapy on cardiac and atrioventricular valve function through 12 months of follow-up","volume":"12","author":"Beurskens","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib5","doi-asserted-by":"crossref","first-page":"2603","DOI":"10.1016\/j.hrthm.2024.06.030","article-title":"Low prevalence of new-onset severe tricuspid regurgitation following leadless pacemaker implantation in a large series of consecutive patients","volume":"21","author":"La Fazia","year":"2024","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.08.010_bib6","doi-asserted-by":"crossref","first-page":"2131","DOI":"10.1016\/j.jacc.2024.08.077","article-title":"Ten years of leadless cardiac pacing","volume":"84","author":"Breeman","year":"2024","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib7","doi-asserted-by":"crossref","first-page":"2023","DOI":"10.1016\/j.hrthm.2020.05.022","article-title":"Safety of leadless pacemaker implantation in the very elderly","volume":"17","author":"Pagan","year":"2020","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.08.010_bib8","doi-asserted-by":"crossref","first-page":"2360","DOI":"10.1056\/NEJMoa2300080","article-title":"A dual-chamber leadless pacemaker","volume":"388","author":"Knops","year":"2023","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2026.08.010_bib9","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.jacep.2019.10.017","article-title":"Atrioventricular synchronous pacing using a leadless ventricular pacemaker: results from the MARVEL 2 study","volume":"6","author":"Steinwender","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib10","doi-asserted-by":"crossref","first-page":"1978","DOI":"10.1016\/j.hrthm.2026.04.014","article-title":"LEAP2: a first-in-human evaluation of a chronically implanted novel leadless pacemaker for conduction system pacing","volume":"23","author":"Reddy","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.08.010_bib11","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCIMAGING.116.005332","article-title":"State-of-the-art review of echocardiographic imaging in the evaluation and treatment of functional tricuspid regurgitation","volume":"9","author":"Hahn","year":"2016","journal-title":"Circ Cardiovasc Imaging"},{"key":"10.1016\/j.hrthm.2026.08.010_bib12","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1097\/CRD.0b013e3182880751","article-title":"Contemporary management of tricuspid regurgitation: an updated clinical review","volume":"21","author":"Taylor","year":"2013","journal-title":"Cardiol Rev"},{"issue":"suppl 9","key":"10.1016\/j.hrthm.2026.08.010_bib13","doi-asserted-by":"crossref","first-page":"1723","DOI":"10.1016\/S0735-1097(22)02714-0","article-title":"Contemporary prevalence of valvular heart disease & diagnostic variability across centers","volume":"79","author":"Brennan","year":"2022","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib14","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.ijcard.2013.04.043","article-title":"Functional tricuspid regurgitation: an underestimated issue","volume":"168","author":"Di Mauro","year":"2013","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib15","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1093\/eurheartj\/ehae088","article-title":"Atrial secondary tricuspid regurgitation: pathophysiology, definition, diagnosis, and treatment","volume":"45","author":"Muraru","year":"2024","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2026.08.010_bib16","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1093\/ehjci\/jeac009","article-title":"Tricuspid regurgitation: recent advances in understanding pathophysiology, severity grading and outcome","volume":"23","author":"Hahn","year":"2022","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.hrthm.2026.08.010_bib17","doi-asserted-by":"crossref","first-page":"2331","DOI":"10.1016\/j.jacc.2017.02.055","article-title":"Tricuspid valve dysfunction following pacemaker or cardioverter-defibrillator implantation","volume":"69","author":"Chang","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib18","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/j.ijcard.2022.10.160","article-title":"Prevalence and prognostic impact of tricuspid regurgitation in patients with cardiac implantable electronic devices: from the national echocardiography database of Australia","volume":"370","author":"Offen","year":"2023","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib19","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1111\/pace.12701","article-title":"Tricuspid regurgitation following implantation of endocardial leads: incidence and predictors","volume":"38","author":"Lee","year":"2015","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib20","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.jcmg.2013.11.007","article-title":"3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation","volume":"7","author":"Mediratta","year":"2014","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1016\/j.hrthm.2026.08.010_bib21","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1093\/ejechocard\/jeq018","article-title":"Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrode","volume":"11","author":"Vaturi","year":"2010","journal-title":"Eur J Echocardiogr"},{"key":"10.1016\/j.hrthm.2026.08.010_bib22","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1111\/pace.13543","article-title":"Incidence and predictors of moderate to severe tricuspid regurgitation after dual-chamber pacemaker implantation","volume":"42","author":"Cho","year":"2019","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib23","doi-asserted-by":"crossref","first-page":"5543","DOI":"10.3390\/jcm13185543","article-title":"Tricuspid regurgitation associated with implantable cardiac devices: a double-edged sword","volume":"13","author":"Iliescu","year":"2024","journal-title":"J Clin Med"},{"key":"10.1016\/j.hrthm.2026.08.010_bib24","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/j.hrthm.2025.07.031","article-title":"Relationship between cardiac implantable electronic devices and tricuspid regurgitation in the general population","volume":"23","author":"Bowman","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.08.010_bib25","doi-asserted-by":"crossref","first-page":"2058","DOI":"10.1016\/j.jcin.2023.04.018","article-title":"The impact and outcomes of right ventricular lead extraction in CIED-related tricuspid regurgitation","volume":"16","author":"Sorajja","year":"2023","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2026.08.010_bib26","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1111\/jce.16227","article-title":"Outcomes of tricuspid regurgitation after lead extraction","volume":"35","author":"Shanafelt","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib28","doi-asserted-by":"crossref","first-page":"1979","DOI":"10.1093\/eurheartj\/ehaf119","article-title":"Leadless pacing: a comprehensive review","volume":"46","author":"Saleem-Talib","year":"2025","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2026.08.010_bib29","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1056\/NEJMoa1511643","article-title":"A leadless intracardiac transcatheter pacing system","volume":"374","author":"Reynolds","year":"2016","journal-title":"N Engl J Med"},{"key":"10.1016\/j.hrthm.2026.08.010_bib30","doi-asserted-by":"crossref","first-page":"1800","DOI":"10.1016\/j.hrthm.2018.08.005","article-title":"Updated performance of the Micra transcatheter pacemaker in the real-world setting: a comparison to the investigational study and a transvenous historical control","volume":"15","author":"El-Chami","year":"2018","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.08.010_bib31","doi-asserted-by":"crossref","first-page":"2002","DOI":"10.1111\/jce.14083","article-title":"Leadless pacing with Micra TPS: a comparison between right ventricular outflow tract, mid-septal, and apical implant sites","volume":"30","author":"Garweg","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib32","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.1111\/pace.14587","article-title":"The jugular approach for leadless pacing: a novel and safe alternative","volume":"45","author":"Saleem-Talib","year":"2022","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib33","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1111\/jce.13092","article-title":"How to implant a leadless pacemaker with a tine-based fixation","volume":"27","author":"El-Chami","year":"2016","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib34","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.122.025339","article-title":"Leadless or conventional transvenous ventricular permanent pacemakers: a nationwide matched control study","volume":"11","author":"Bodin","year":"2022","journal-title":"J Am Heart Assoc"},{"key":"10.1016\/j.hrthm.2026.08.010_bib35","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1093\/europace\/eux101","article-title":"Right ventricular and tricuspid valve function in patients chronically implanted with leadless pacemakers","volume":"20","author":"Salaun","year":"2018","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.08.010_bib36","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.120.009530","article-title":"Close proximity of leadless pacemaker to tricuspid annulus predicts worse tricuspid regurgitation following septal implantation","volume":"14","author":"Hai","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"suppl 1","key":"10.1016\/j.hrthm.2026.08.010_bib37","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/S0735-1097(21)01606-5","article-title":"Outcomes of leadless pacing on tricuspid valve and right ventricular function","volume":"77","author":"Dabas","year":"2021","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib38","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2021.06.971","article-title":"B-PO05-051 association of leadless pacemaker implantation with tricuspid regurgitation","volume":"18","author":"Mahmood","year":"2021","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.08.010_bib39","doi-asserted-by":"crossref","first-page":"1617","DOI":"10.1111\/jce.15565","article-title":"Evolution of tricuspid valve regurgitation after implantation of a leadless pacemaker: a single center experience, systematic review, and meta-analysis","volume":"33","author":"Haeberlin","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib40","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1253\/circj.CJ-21-0889","article-title":"Clinical outcomes of non-atrial fibrillation bradyarrhythmias treated with a ventricular demand leadless pacemaker compared with an atrioventricular synchronous transvenous pacemaker - a propensity score-matched analysis","volume":"86","author":"Sasaki","year":"2022","journal-title":"Circ J"},{"key":"10.1016\/j.hrthm.2026.08.010_bib41","doi-asserted-by":"crossref","first-page":"2233","DOI":"10.1111\/jce.16046","article-title":"Association of leadless pacing with ventricular and valvular function","volume":"34","author":"Arps","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib42","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1111\/pace.14870","article-title":"Evolution of ventricular and valve function in patients with right ventricular pacing - a randomized controlled trial comparing leadless and conventional pacing","volume":"46","author":"Garweg","year":"2023","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib43","doi-asserted-by":"crossref","first-page":"5491","DOI":"10.19102\/icrm.2023.14062","article-title":"Two-year outcomes of ventricular-demand leadless pacemaker therapy for heart block after transcatheter aortic valve replacement","volume":"14","author":"Togashi","year":"2023","journal-title":"J Innov Card Rhythm Manag"},{"key":"10.1016\/j.hrthm.2026.08.010_bib44","doi-asserted-by":"crossref","first-page":"S634","DOI":"10.1016\/j.hrthm.2025.03.1555","article-title":"PO-06-007 incidence of worsening tricuspid regurgitation following implantation of leadless versus dual-chamber pacemakers","volume":"22","author":"Aldaas","year":"2025","journal-title":"Heart Rhythm"},{"issue":"suppl 13","key":"10.1016\/j.hrthm.2026.08.010_bib45","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/S0735-1097(24)02076-X","article-title":"Prevalence of tricuspid regurgitation in leadless versus transvenous pacemakers","volume":"83","author":"Xia","year":"2024","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib46","doi-asserted-by":"crossref","first-page":"e951","DOI":"10.1016\/j.hrthm.2025.12.045","article-title":"Tricuspid valve regurgitation with single- and dual-chamber helix-fixation leadless pacemakers","volume":"23","author":"Hadadi","year":"2026","journal-title":"Heart Rhythm"},{"issue":"suppl 2","key":"10.1016\/j.hrthm.2026.08.010_bib47","article-title":"Impact of leadless pacemaker therapy on tricuspid regurgitation","volume":"44","author":"Mendoza","year":"2023","journal-title":"Eur Heart J"},{"key":"10.1016\/j.hrthm.2026.08.010_bib48","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2026.03.267","article-title":"PO-FPII-306 incidence and predictors of tricuspid regurgitation worsening with leadless pacemakers; analysis from the leadless-TR registry","volume":"23","author":"Abdelsayed","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.08.010_bib49","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacc.2026.02.093","article-title":"26-A-13859-ACC effect of leadless pacemaker implantation on tricuspid regurgitation","volume":"87","author":"Eisenberg","year":"2026","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib50","doi-asserted-by":"crossref","first-page":"1643","DOI":"10.1111\/pace.14862","article-title":"Revisiting predictors of worse atrioventricular valve and left ventricular systolic function following pacemaker therapy","volume":"46","author":"Sasaki","year":"2023","journal-title":"Pacing Clin Electrophysiol"},{"issue":"suppl 3","key":"10.1016\/j.hrthm.2026.08.010_bib51","first-page":"A4371842","article-title":"Impact of leadless versus transvenous pacemakers on tricuspid valve function: a propensity-matched multicenter time-to-event study (the LEADLESS-TR)","volume":"152","author":"Abdelsayed","year":"2025","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.08.010_bib52","doi-asserted-by":"crossref","first-page":"359","DOI":"10.31083\/j.rcm2510359","article-title":"Comparison of postoperative outcomes between leadless and conventional transvenous pacemakers implantation: an up-to-date meta-analysis","volume":"25","author":"Dai","year":"2024","journal-title":"Rev Cardiovasc Med"},{"key":"10.1016\/j.hrthm.2026.08.010_bib53","doi-asserted-by":"crossref","first-page":"1362","DOI":"10.1111\/jce.16672","article-title":"Comparative analysis of leadless versus transvenous pacemakers in non-heart failure patients: a multicenter US retrospective study","volume":"36","author":"Fouad","year":"2025","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib54","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1016\/j.jcin.2024.05.030","article-title":"Comparison of patient outcomes between leadless vs transvenous pacemakers following transcatheter aortic valve replacement","volume":"17","author":"Ueyama","year":"2024","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2026.08.010_bib55","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1093\/europace\/euz357","article-title":"Factors influencing the use of leadless or transvenous pacemakers: results of the European Heart Rhythm Association Prospective Survey","volume":"22","author":"Boveda","year":"2020","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.08.010_bib56","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.jacep.2021.11.002","article-title":"Primary results on safety and efficacy from the LEADLESS II-phase 2 worldwide clinical trial","volume":"8","author":"Reddy","year":"2022","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib57","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.hrcr.2024.10.020","article-title":"A case of severe tricuspid regurgitation with rupture of tricuspid valve chordae tendineae caused by leadless pacemaker implantation","volume":"11","author":"Omura","year":"2025","journal-title":"HeartRhythm Case Rep"},{"key":"10.1016\/j.hrthm.2026.08.010_bib58","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1253\/circj.CJ-21-0860","article-title":"Severe tricuspid regurgitation with chordae tendinae rupture after leadless pacemaker implantation","volume":"86","author":"Kobara","year":"2022","journal-title":"Circ J"},{"key":"10.1016\/j.hrthm.2026.08.010_bib59","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1111\/pace.14400","article-title":"Leadless pacemaker implantation: an unexpected complication","volume":"45","author":"Berdaoui","year":"2022","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib60","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.1007\/s10840-025-02099-4","article-title":"Procedural tricuspid valve damage associated with leadless pacemakers","volume":"68","author":"Bahbah","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib61","article-title":"Tricuspid leaflet flail after Micra\u2122 leadless pacemaker implantation: a case report","volume":"6","author":"Pingitore","year":"2022","journal-title":"Eur Heart J Case Rep"},{"key":"10.1016\/j.hrthm.2026.08.010_bib62","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1093\/europace\/euaa097","article-title":"Leadless pacemaker implantation quality: importance of the operator\u2019s experience","volume":"22","author":"Haeberlin","year":"2020","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.08.010_bib63","doi-asserted-by":"crossref","first-page":"797","DOI":"10.5603\/CJ.a2019.0053","article-title":"Echocardiographic assessment of tricuspid regurgitation and pericardial effusion after cardiac device implantation","volume":"27","author":"Wiechecka","year":"2020","journal-title":"Cardiol J"},{"key":"10.1016\/j.hrthm.2026.08.010_bib64","doi-asserted-by":"crossref","first-page":"2220","DOI":"10.1111\/jce.16444","article-title":"A meta-analysis of the distance between lead-implanted site and tricuspid valve annulus with postoperative tricuspid regurgitation deterioration in patients with left bundle branch area pacing","volume":"35","author":"Karwiky","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib65","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.hrcr.2024.10.017","article-title":"Tricuspid regurgitation complicating leadless pacemaker implantation: surgical intervention for pacemaker removal and tricuspid valve replacement","volume":"11","author":"Kilaru","year":"2025","journal-title":"HeartRhythm Case Rep"},{"key":"10.1016\/j.hrthm.2026.08.010_bib66","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.case.2021.06.003","article-title":"Beyond the wires: a case of leadless pacemaker-mediated tricuspid regurgitation","volume":"5","author":"Cirne","year":"2021","journal-title":"CASE (Phila)"},{"key":"10.1016\/j.hrthm.2026.08.010_bib67","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1016\/j.hrcr.2024.09.012","article-title":"Tricuspid valve complication following leadless pacemaker implantation requiring device extraction","volume":"10","author":"Adams","year":"2024","journal-title":"HeartRhythm Case Rep"},{"issue":"suppl 2","key":"10.1016\/j.hrthm.2026.08.010_bib68","doi-asserted-by":"crossref","first-page":"ii26","DOI":"10.1093\/eurheartjsupp\/suae119","article-title":"Long-term management of leadless pacemakers","volume":"27","author":"Andreae","year":"2025","journal-title":"Eur Heart J Suppl"},{"key":"10.1016\/j.hrthm.2026.08.010_bib69","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1161\/CIRCEP.115.003101","article-title":"Postmortem histopathological examination of a leadless pacemaker shows partial encapsulation after 19 months","volume":"8","author":"Tjong","year":"2015","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib70","doi-asserted-by":"crossref","first-page":"6126","DOI":"10.19102\/icrm.2024.15126","article-title":"Challenging extraction and replacement of an eight-year-old Nanostim leadless pacemaker and AVEIR implant","volume":"15","author":"Czulada","year":"2024","journal-title":"J Innov Card Rhythm Manag"},{"key":"10.1016\/j.hrthm.2026.08.010_bib71","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1111\/jce.15343","article-title":"Leadless pacemaker perforations: clinical consequences and related device and user problems","volume":"33","author":"Hauser","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib72","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1007\/s10840-024-01936-2","article-title":"Outcomes of leadless pacemaker implantation in the United States based on sex","volume":"68","author":"Khan","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib73","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1093\/europace\/euaa367","volume":"23","author":"Burri","year":"2021","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.08.010_bib74","doi-asserted-by":"crossref","DOI":"10.1002\/clc.70209","article-title":"Computed tomography-verified pacing location of Micra leadless pacemakers and characteristics of paced electrocardiograms in bradycardia patients","volume":"48","author":"Zhang","year":"2025","journal-title":"Clin Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib75","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1111\/pace.14437","article-title":"Leadless pacemaker implantation sites confirmed by computed tomography and their parameters and complication rates","volume":"45","author":"Arai","year":"2022","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib76","doi-asserted-by":"crossref","first-page":"e17","DOI":"10.1016\/j.hrthm.2023.03.1538","article-title":"HRS\/APHRS\/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure","volume":"20","author":"Chung","year":"2023","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.08.010_bib77","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae143","article-title":"Evolution and prognosis of tricuspid and mitral regurgitation following cardiac implantable electronic devices: a systematic review and meta-analysis","volume":"26","author":"Yuyun","year":"2024","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.08.010_bib78","series-title":"StatPearls. Treasure Island, FL","article-title":"Pacemaker Syndrome","author":"Iqbal","year":"2025"},{"key":"10.1016\/j.hrthm.2026.08.010_bib79","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0235230","article-title":"Prevalence, predictors, and prognosis of tricuspid regurgitation following permanent pacemaker implantation","volume":"15","author":"Seo","year":"2020","journal-title":"PLoS One"},{"key":"10.1016\/j.hrthm.2026.08.010_bib80","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.1016\/j.amjcard.2015.09.041","article-title":"Effect of Right ventricular Pacing on Right ventricular Mechanics and tricuspid Regurgitation in Patients with High-Grade atrioventricular Block and Sinus Rhythm (from the Protection of Left ventricular Function During Right ventricular Pacing Study)","volume":"116","author":"Saito","year":"2015","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib81","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20220788","article-title":"The application of fluoroscopic criteria to define leadless pacemakers implant position and the effect of location on device performance","volume":"96","author":"ElRefai","year":"2023","journal-title":"Br J Radiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib82","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.ijcard.2022.12.011","article-title":"Cardiac implantable electronic devices: leads can lead to tricuspid regurgitation and death","volume":"372","author":"Dreyfus","year":"2023","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib83","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.hroo.2022.10.005","article-title":"Exploratory use of intraprocedural transesophageal echocardiography to guide implantation of the leadless pacemaker","volume":"4","author":"Gheyath","year":"2023","journal-title":"Heart Rhythm O2"},{"key":"10.1016\/j.hrthm.2026.08.010_bib84","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1111\/pace.14770","article-title":"Second Micra leadless pacemaker implantation by using intracardiac echocardiography","volume":"47","author":"Kusume","year":"2024","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib85","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.hrcr.2024.05.007","article-title":"Triventricular pacing with leadless pacemaker combined with cardiac resynchronization therapy in severe heart failure","volume":"10","author":"Park","year":"2024","journal-title":"HeartRhythm Case Rep"},{"key":"10.1016\/j.hrthm.2026.08.010_bib86","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1161\/CIRCULATIONAHA.121.055019","article-title":"The clinical impact of device lead-associated tricuspid regurgitation: need for a multidisciplinary approach","volume":"145","author":"Vij","year":"2022","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.08.010_bib87","doi-asserted-by":"crossref","first-page":"174","DOI":"10.33963\/v.phj.110748","article-title":"Transvenous leadless pacemaker extraction: when, who, where and how?","volume":"84","author":"Tajstra","year":"2026","journal-title":"Kardiol Pol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib88","article-title":"Percutaneous extraction of a leadless Micra pacemaker after dislocation: a case report","volume":"3","author":"Fichtner","year":"2019","journal-title":"Eur Heart Case Rep"},{"key":"10.1016\/j.hrthm.2026.08.010_bib89","first-page":"1395","article-title":"Management of cardiac implantable electronic devices in patients with severe symptomatic tricuspid regurgitation\u2014proposed algorithm and selected case examples","volume":"105","author":"Kerolos","year":"2025","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.hrthm.2026.08.010_bib90","doi-asserted-by":"crossref","first-page":"e1269","DOI":"10.1016\/j.hrthm.2025.07.049","article-title":"Cardiac implantable electronic device implantation and function after transcatheter tricuspid valve replacement","volume":"22","author":"Braunstein","year":"2025","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.08.010_bib91","doi-asserted-by":"crossref","first-page":"2224","DOI":"10.1016\/j.jacep.2024.06.018","article-title":"Long-term safety and efficacy of intraoperative leadless pacemaker implantation during valve surgery","volume":"10","author":"Oates","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.08.010_bib92","doi-asserted-by":"crossref","first-page":"1806","DOI":"10.1016\/j.jcin.2025.04.016","article-title":"Is leadless pacemaker always the best option before transcatheter tricuspid valve replacement?","volume":"18","author":"Skalidis","year":"2025","journal-title":"JACC Cardiovasc Interv"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126026767?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126026767?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T21:35:53Z","timestamp":1790890553000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527126026767"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":91,"alternative-id":["S1547527126026767"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.08.010","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Tricuspid regurgitation and leadless pacemakers: A state-of-the-art review","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.08.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.07.031","name":"associatedlink","label":"CrossRef DOI link to the associated document"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Heart Rhythm Society. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}