{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T03:41:00Z","timestamp":1792640460805,"version":"4.5.0"},"reference-count":54,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.hrthm.2026.09.054","type":"journal-article","created":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T23:46:24Z","timestamp":1791330384000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical Implications of Hemolysis after Pulsed Field Ablation - What Can We Learn from Benchtop Models and Preclinical Experiments"],"prefix":"10.1016","author":[{"given":"Nishaki","family":"Mehta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Damijan","family":"Miklav\u010di\u010d","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay S.","family":"Raval","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atul","family":"Verma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ammar M.","family":"Killu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lars","family":"Mattison","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel C.","family":"Sigg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2026.09.054_bib1","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/j.hrthm.2025.12.022","article-title":"Pulsed field ablation: Disrupting technology in cardiac electrophysiology","volume":"23","author":"Miklavcic","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib2","doi-asserted-by":"crossref","first-page":"2020","DOI":"10.1038\/s41591-024-03114-3","article-title":"Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study","volume":"30","author":"Ekanem","year":"2024","journal-title":"Nat Med"},{"key":"10.1016\/j.hrthm.2026.09.054_bib3","doi-asserted-by":"crossref","first-page":"1431","DOI":"10.1016\/j.jacep.2026.04.024","article-title":"Intravascular Hemolysis and Pulsed-Field Ablation: State of the Art Review","volume":"12","author":"Coleman","year":"2026","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib4","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.hrthm.2024.08.019","article-title":"Significant hemolysis is present during irreversible electroporation of cardiomyocytes in vitro","volume":"22","author":"Fiserova","year":"2025","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib5","doi-asserted-by":"crossref","first-page":"1923","DOI":"10.1073\/pnas.74.5.1923","article-title":"Hemolysis of human erythrocytes by transient electric field","volume":"74","author":"Kinosita","year":"1977","journal-title":"Proc Natl Acad Sci U S A"},{"key":"10.1016\/j.hrthm.2026.09.054_bib6","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/0005-2736(77)90252-8","article-title":"Voltage-induced pore formation and hemolysis of human erythrocytes","volume":"471","author":"Kinosita","year":"1977","journal-title":"Biochim Biophys Acta"},{"key":"10.1016\/j.hrthm.2026.09.054_bib7","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2023.1160231","article-title":"Determination of lethal electric field threshold for pulsed field ablation in ex vivo perfused porcine and human hearts","volume":"10","author":"Kos","year":"2023","journal-title":"Front Cardiovasc Med"},{"key":"10.1016\/j.hrthm.2026.09.054_bib8","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1007\/s10840-023-01733-3","article-title":"Pulsed-field ablation of atrial fibrillation: kinetics of release of multiple cardiac biomarkers","volume":"67","author":"Casella","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib9","first-page":"1688","article-title":"Cardiac biomarker temporal dynamics after radiofrequency and pulsed field catheter ablation of atrial fibrillation","volume":"6","author":"Casella","year":"2025","journal-title":"Heart Rhythm O2"},{"key":"10.1016\/j.hrthm.2026.09.054_bib10","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1111\/ijlh.13457","article-title":"Plasma hemoglobin: A method comparison of six assays for hemoglobin and hemolysis index measurement","volume":"43","author":"Calvaresi","year":"2021","journal-title":"Int J Lab Hematol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib11","doi-asserted-by":"crossref","first-page":"174","DOI":"10.3122\/jabfm.2024.240224R1","article-title":"Interpretating Normal Values and Reference Ranges for Laboratory Tests","volume":"38","author":"Doles","year":"2025","journal-title":"J Am Board Fam Med"},{"key":"10.1016\/j.hrthm.2026.09.054_bib12","doi-asserted-by":"crossref","first-page":"1901","DOI":"10.1038\/s41372-021-01119-1","article-title":"Risk factors for acute kidney injury in neonates with congenital diaphragmatic hernia","volume":"41","author":"Liberio","year":"2021","journal-title":"J Perinatol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib13","doi-asserted-by":"crossref","first-page":"e111","DOI":"10.1097\/PCC.0000000000000047","article-title":"Cardiopulmonary bypass is associated with hemolysis and acute kidney injury in neonates, infants, and children","volume":"15","author":"Mamikonian","year":"2014","journal-title":"Pediatr Crit Care Med"},{"key":"10.1016\/j.hrthm.2026.09.054_bib14","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.1001\/jama.293.13.1653","article-title":"The clinical sequelae of intravascular hemolysis and extracellular plasma hemoglobin: a novel mechanism of human disease","volume":"293","author":"Rother","year":"2005","journal-title":"JAMA"},{"key":"10.1016\/j.hrthm.2026.09.054_bib15","doi-asserted-by":"crossref","first-page":"1383","DOI":"10.1038\/nm1202-799","article-title":"Cell-free hemoglobin limits nitric oxide bioavailability in sickle-cell disease","volume":"8","author":"Reiter","year":"2002","journal-title":"Nat Med"},{"key":"10.1016\/j.hrthm.2026.09.054_bib16","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.resuscitation.2022.10.008","article-title":"Different half-life of free haemoglobin and NSE may falsely predict poor prognosis after cardiac arrest","volume":"181","author":"Iten","year":"2022","journal-title":"Resuscitation"},{"key":"10.1016\/j.hrthm.2026.09.054_bib17","doi-asserted-by":"crossref","first-page":"1276","DOI":"10.1182\/blood-2012-11-451229","article-title":"Hemolysis and free hemoglobin revisited: exploring hemoglobin and hemin scavengers as a novel class of therapeutic proteins","volume":"121","author":"Schaer","year":"2013","journal-title":"Blood"},{"key":"10.1016\/j.hrthm.2026.09.054_bib18","doi-asserted-by":"crossref","first-page":"3524","DOI":"10.1182\/blood.V91.9.3524","article-title":"Congenital anhaptoglobinemia versus acquired hypohaptoglobinemia","volume":"91","author":"Delanghe","year":"1998","journal-title":"Blood"},{"key":"10.1016\/j.hrthm.2026.09.054_bib19","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1182\/blood.V95.4.1138.004k27_1138_1143","article-title":"Simple PCR detection of haptoglobin gene deletion in anhaptoglobinemic patients with antihaptoglobin antibody that causes anaphylactic transfusion reactions","volume":"95","author":"Koda","year":"2000","journal-title":"Blood"},{"key":"10.1016\/j.hrthm.2026.09.054_bib20","first-page":"1","article-title":"Effect of injury on plasma proteins","volume":"9","author":"Owen","year":"1967","journal-title":"Adv Clin Chem"},{"key":"10.1016\/j.hrthm.2026.09.054_bib21","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1002\/ajh.23623","article-title":"Haptoglobin testing in hemolysis: measurement and interpretation","volume":"89","author":"Shih","year":"2014","journal-title":"Am J Hematol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib22","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2026.04.028","article-title":"Patient vulnerability associated with acute kidney injury after pulsed field ablation: A role for baseline biomarkers and haptoglobin phenotype","author":"Suga","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib23","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2026.05.026","article-title":"Association between baseline haptoglobin and early renal injury after pulsed-field ablation","author":"Tanaka","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib24","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2026.05.050","article-title":"Haptoglobin, hemolysis, and renal vulnerability after pulsed field ablation: The hemoglobin-binding reserve","author":"Levy","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib25","unstructured":"Kalakonda A, Jenkins BA, John S. Physiology, Bilirubin. StatPearls. Treasure Island (FL)2026."},{"key":"10.1016\/j.hrthm.2026.09.054_bib26","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.bioelechem.2017.12.005","article-title":"In vitro electroporation detection methods - An overview","volume":"120","author":"Batista Napotnik","year":"2018","journal-title":"Bioelectrochemistry"},{"key":"10.1016\/j.hrthm.2026.09.054_bib27","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2026.02.006","article-title":"2026 HRS\/EHRA Scientific Statement on Pulsed Field Ablation for Cardiac Arrhythmias","author":"Verma","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib28","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.yjmcc.2021.12.007","article-title":"Systematic transcriptomic and phenotypic characterization of human and murine cardiac myocyte cell lines and primary cardiomyocytes reveals serious limitations and low resemblances to adult cardiac phenotype","volume":"165","author":"Onodi","year":"2022","journal-title":"J Mol Cell Cardiol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib29","doi-asserted-by":"crossref","DOI":"10.1016\/j.ifset.2024.103628","article-title":"Time-dependent model of temperature distribution in continuous flow pulsed electric field treatment chambers","volume":"93","author":"Lombergar","year":"2024","journal-title":"Innovative Food Science & Emerging Technologies"},{"key":"10.1016\/j.hrthm.2026.09.054_bib30","doi-asserted-by":"crossref","unstructured":"Nies M, Koruth JS, Mlcek M, et al. Hemolysis After Pulsed Field Ablation: Impact of Lesion Number and Catheter-Tissue Contact. Circ Arrhythm Electrophysiol 2024e012765.","DOI":"10.1161\/CIRCEP.124.012765"},{"key":"10.1016\/j.hrthm.2026.09.054_bib31","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.124.013317","article-title":"Hemolysis After Pulsed Field Ablation: The Role of Dose and Contact in an Acute Porcine Model","volume":"17","author":"Mattison","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib32","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/S0009-9120(75)91005-X","article-title":"A spectrophotometric scanning technique for the rapid determination of plasma hemoglobin","volume":"8","author":"Blakney","year":"1975","journal-title":"Clin Biochem"},{"key":"10.1016\/j.hrthm.2026.09.054_bib33","unstructured":"Villar-Mead JP, Thinamany S, Mattison LM, et al. In Vitro Evaluation of Pulsed Field Ablation-Induced Hemolysis Using Bovine Blood in a Benchtop Model. Electroporation Based Technologies and Treatments. Ljubljana, Slovenia2025."},{"key":"10.1016\/j.hrthm.2026.09.054_bib34","doi-asserted-by":"crossref","first-page":"3279","DOI":"10.1109\/TBME.2011.2167232","article-title":"Equivalent pulse parameters for electroporation","volume":"58","author":"Pucihar","year":"2011","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.hrthm.2026.09.054_bib35","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.bioelechem.2018.03.005","article-title":"Recommendations and requirements for reporting on applications of electric pulse delivery for electroporation of biological samples","volume":"122","author":"Cemazar","year":"2018","journal-title":"Bioelectrochemistry"},{"key":"10.1016\/j.hrthm.2026.09.054_bib36","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.ifset.2016.08.003","article-title":"Recommendations guidelines on the key information to be reported in studies of application of PEF technology in food and biotechnological processes","volume":"37","author":"Raso","year":"2016","journal-title":"Innovative Food Science & Emerging Technologies"},{"key":"10.1016\/j.hrthm.2026.09.054_bib37","doi-asserted-by":"crossref","first-page":"3788","DOI":"10.1038\/s41598-021-83327-5","article-title":"Point-of-care testing of plasma free hemoglobin and hematocrit for mechanical circulatory support","volume":"11","author":"Shin","year":"2021","journal-title":"Sci Rep"},{"key":"10.1016\/j.hrthm.2026.09.054_bib38","doi-asserted-by":"crossref","first-page":"5101","DOI":"10.1038\/s41598-020-62041-8","article-title":"A simple method to monitor hemolysis in real time","volume":"10","author":"Van Buren","year":"2020","journal-title":"Sci Rep"},{"key":"10.1016\/j.hrthm.2026.09.054_bib39","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.125.013787","article-title":"Minimal Hemolytic Profile of the Monopolar Lattice-Tip Pulse Field Ablation System: An In Vivo Preclinical Porcine Assessment","volume":"18","author":"Watanabe","year":"2025","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib40","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-024-83683-y","article-title":"Biophysics and electrophysiology of pulsed field ablation in normal and infarcted porcine cardiac ventricular tissue","volume":"14","author":"Miklavcic","year":"2024","journal-title":"Sci Rep"},{"key":"10.1016\/j.hrthm.2026.09.054_bib41","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euag190","article-title":"Haemolysis and renal effects across pulsed field ablation systems in atrial fibrillation","volume":"28","author":"Rocchetti","year":"2026","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.09.054_bib42","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euag005","article-title":"Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter","volume":"28","author":"Zhou","year":"2026","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.09.054_bib43","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euaf278","article-title":"Assessment of temperature dynamics in pulsed field ablation with a variable-loop circular catheter: a comparative analysis of waveform configurations and irrigation rates in specimens of bovine ventricular myocardium","volume":"27","author":"Zito","year":"2025","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.09.054_bib44","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/j.hrthm.2025.05.072","article-title":"Comparison of hemolysis with different pulsed field ablation systems","volume":"23","author":"Kawamura","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib45","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad371","article-title":"Severe acute kidney injury related to haemolysis after pulsed field ablation for atrial fibrillation","volume":"26","author":"Venier","year":"2023","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.09.054_bib46","article-title":"Peri-Procedural Intravascular Hemolysis during Atrial Fibrillation Ablation: A Comparison of Pulsed Field with Radiofrequency Ablation","author":"Osmancik","year":"2024","journal-title":"JACC: Clinical Electrophysiology"},{"key":"10.1016\/j.hrthm.2026.09.054_bib47","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae102.796","article-title":"Characterization and clinical significance of hemolysis after pulsed-field ablation for atrial fibrillation: insights from a multicentric analysis","volume":"26","author":"Popa","year":"2024","journal-title":"EP Europace"},{"key":"10.1016\/j.hrthm.2026.09.054_bib48","article-title":"Hemolysis and kidney injury after catheter ablation for atrial fibrillation: Microsecond vs nanosecond pulsed field ablation","author":"Ding","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib49","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2026.01.026","article-title":"Hemolysis and renal safety of pulsed-field vs thermal ablation for atrial fibrillation: A systematic review and meta-analysis","author":"Kilic","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib50","doi-asserted-by":"crossref","first-page":"2498","DOI":"10.1111\/jce.70049","article-title":"Hemolysis Induced by Pulsed-Field Ablation of Atrial Arrhythmias: A Comparative Analysis of Current Systems","volume":"36","author":"Bruss","year":"2025","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib51","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.jacep.2023.12.008","article-title":"Acute Kidney Injury Resulting From Hemoglobinuria After Pulsed-Field Ablation in Atrial Fibrillation: Is it Preventable?","volume":"10","author":"Mohanty","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib52","doi-asserted-by":"crossref","first-page":"e861","DOI":"10.1016\/j.hrthm.2026.01.018","article-title":"Thromboinflammation and hemolysis after pulsed field ablation with a pentaspline catheter: Clinical predictors, renal safety, and rhythm outcomes","volume":"23","author":"Popa","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.09.054_bib53","doi-asserted-by":"crossref","DOI":"10.1111\/jce.70438","article-title":"Impact of Pulse Field Ablation on Hemolysis Markers: A Single-Center Experience","author":"Yeo","year":"2026","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.09.054_bib54","doi-asserted-by":"crossref","first-page":"e24","DOI":"10.15420\/aer.2025.37","article-title":"Complexity and Perplexity of Pulsed Field Ablation: An Engineering Perspective","volume":"14","author":"Kos","year":"2025","journal-title":"Arrhythm Electrophysiol Rev"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126028584?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126028584?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T03:18:28Z","timestamp":1792639108000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527126028584"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":54,"alternative-id":["S1547527126028584"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.09.054","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Clinical Implications of Hemolysis after Pulsed Field Ablation - What Can We Learn from Benchtop Models and Preclinical Experiments","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.09.054","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Published by Elsevier Inc. on behalf of Heart Rhythm Society.","name":"copyright","label":"Copyright"}]}}