{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T02:31:42Z","timestamp":1793327502630,"version":"4.5.0"},"reference-count":27,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T00:00:00Z","timestamp":1792368000000},"content-version":"vor","delay-in-days":18,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster Inc","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","heartrhythmjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heart Rhythm"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.hrthm.2026.10.008","type":"journal-article","created":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T06:20:24Z","timestamp":1792650024000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Pulmonary Vein Isolation With Contact-Force-Sensing Large-Tip Focal Pulsed Field Ablation Catheter With 3D Mapping for Paroxysmal Atrial Fibrillation: Omny-IRE 12-month Results"],"prefix":"10.1016","author":[{"given":"Mattias","family":"Duytschaever","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johan","family":"Vijgen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petr","family":"Neuzil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Massimo","family":"Grimaldi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atul","family":"Verma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom","family":"De Potter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laurent","family":"Macle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josef","family":"Kautzner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominik","family":"Linz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ante","family":"Anic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian","family":"Chun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hugo","family":"Van Herendael","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandre","family":"Almorad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Berte","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rahul","family":"Bhardwaj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Reichlin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moussa","family":"Mansour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boris","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastien","family":"Knecht","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vivek Y.","family":"Reddy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gediminas","family":"Rackauskas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.hrthm.2026.10.008_bib1","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.124.012794","article-title":"Pulsed field ablation using focal contact force-sensing catheters for treatment of atrial fibrillation: 1-Year outcomes of the ECLIPSE AF study","volume":"18","author":"Ani\u0107","year":"2025","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib2","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.123.012667","article-title":"Predictors of success for pulmonary vein isolation with pulsed-field ablation using a variable-loop catheter with 3D mapping integration: complete 12-month outcomes from inspIRE","volume":"17","author":"De Potter","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib3","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1016\/j.jacep.2021.02.014","article-title":"Pulsed field ablation of paroxysmal atrial fibrillation: 1-year outcomes of IMPULSE, PEFCAT, and PEFCAT II","volume":"7","author":"Reddy","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib4","doi-asserted-by":"crossref","first-page":"2551","DOI":"10.1016\/j.hrthm.2025.04.031","article-title":"One-year outcomes of a conformable single-shot pulsed-field ablation catheter for the treatment of paroxysmal atrial fibrillation","volume":"22","author":"Reddy","year":"2025","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.10.008_bib5","doi-asserted-by":"crossref","first-page":"1786","DOI":"10.1016\/j.jacep.2023.04.002","article-title":"A focal ablation catheter toggling between radiofrequency and pulsed field energy to treat atrial fibrillation","volume":"9","author":"Reddy","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib6","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1161\/CIRCULATIONAHA.123.063988","article-title":"Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial","volume":"147","author":"Verma","year":"2023","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.10.008_bib7","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/j.hrthm.2024.04.102","article-title":"AF ablation using a novel \"single-shot\" map-and-ablate spherical array pulsed field ablation catheter: 1-Year outcomes of the first-in-human PULSE-EU trial","volume":"21","author":"Turagam","year":"2024","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.10.008_bib8","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euaf174","article-title":"Dual energy for pulmonary vein isolation using focal ablation technology integrated with a three-dimensional mapping system: SmartfIRE 12-month results","volume":"27","author":"De Potter","year":"2025","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.10.008_bib9","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae134","article-title":"State-of-the-art pulsed field ablation for cardiac arrhythmias: ongoing evolution and future perspective","volume":"26","author":"Chun","year":"2024","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.10.008_bib10","doi-asserted-by":"crossref","first-page":"e2195","DOI":"10.1016\/j.hrthm.2026.02.006","article-title":"2026 HRS\/EHRA scientific statement on pulsed field ablation for cardiac arrhythmias","volume":"23","author":"Verma","year":"2026","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.10.008_bib11","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.123.012717","article-title":"Pulsed field ablation index-guided ablation for lesion formation: impact of contact force and number of applications in the ventricular model","volume":"17","author":"Di Biase","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib12","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.125.014473","article-title":"Safety and chronic atrial lesion formation with a large-tip, contact-force-sensing multipolar pulsed field ablation catheter: effect of application number in a porcine beating heart model","volume":"19","author":"Di Biase","year":"2026","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib13","doi-asserted-by":"crossref","first-page":"2190","DOI":"10.1016\/j.jacep.2025.05.021","article-title":"Esophageal heating and damage with high-power-short-duration radiofrequency and pulsed field ablation","volume":"11","author":"Kocharian","year":"2025","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib14","doi-asserted-by":"crossref","first-page":"1769","DOI":"10.1016\/j.jacep.2025.04.008","article-title":"PVI with CF-sensing large-tip focal PFA catheter with 3D mapping for paroxysmal AF: Omny-IRE 3-month results","volume":"11","author":"Duytschaever","year":"2025","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib15","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1161\/CIRCULATIONAHA.125.077983","article-title":"Life-threatening delayed myocardial ischemia and malignant arrhythmias occurring after pulsed field ablation of atrial fibrillation","volume":"153","author":"Gunawardene","year":"2026","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.10.008_bib16","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1016\/j.hroo.2026.02.031","article-title":"Pulsed field ablation using a large-tip focal contact force\u2013sensing catheter with 3-dimensional mapping integration: 12-Month outcomes from the OMNY-AF pilot phase","volume":"7","author":"Sharma","year":"2026","journal-title":"Heart Rhythm O2"},{"key":"10.1016\/j.hrthm.2026.10.008_bib17","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/j.jacc.2025.10.051","article-title":"Multicenter study on the safety of pulsed field ablation in over 40,000 patients: MANIFEST-US","volume":"87","author":"Turagam","year":"2026","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib18","doi-asserted-by":"crossref","first-page":"1570","DOI":"10.1016\/j.jacep.2026.01.023","article-title":"Pulsed-field vs thermal ablation of atrial fibrillation in patients from the Marshall Islands: a study of generalized coronary spasm","volume":"12","author":"Nair","year":"2026","journal-title":"JACC Clin Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib19","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.ahj.2013.04.015","article-title":"Interpreting changes in quality of life in atrial fibrillation: how much change is meaningful?","volume":"166","author":"Dorian","year":"2013","journal-title":"Am Heart J"},{"key":"10.1016\/j.hrthm.2026.10.008_bib20","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCOUTCOMES.118.005358","article-title":"Defining clinically important difference in the Atrial Fibrillation Effect on Quality-of-Life score","volume":"12","author":"Holmes","year":"2019","journal-title":"Circ Cardiovasc Qual Outcomes"},{"key":"10.1016\/j.hrthm.2026.10.008_bib21","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1161\/CIRCULATIONAHA.124.070333","article-title":"Pulsed field ablation to treat paroxysmal atrial fibrillation: safety and effectiveness in the AdmIRE Pivotal Trial","volume":"150","author":"Reddy","year":"2024","journal-title":"Circulation"},{"key":"10.1016\/j.hrthm.2026.10.008_bib22","doi-asserted-by":"crossref","first-page":"2322","DOI":"10.1016\/j.hrthm.2025.02.017","article-title":"Dose-dependent ventricular lesion formation using a novel large-area pulsed field ablation catheter: a preclinical feasibility study","volume":"22","author":"Kueffer","year":"2025","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.hrthm.2026.10.008_bib23","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1111\/jce.16208","article-title":"Catheter-tissue contact optimizes pulsed electric field ablation with a large area focal catheter","volume":"35","author":"Doshi","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib24","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.122.011209","article-title":"Effect of pulsed-field and radiofrequency ablation on heterogeneous ventricular scar in a swine model of healed myocardial infarction","volume":"15","author":"Younis","year":"2022","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib25","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae043","article-title":"2024 European Heart Rhythm Association\/Heart Rhythm Society\/Asia Pacific Heart Rhythm Society\/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"26","author":"Tzeis","year":"2024","journal-title":"Europace"},{"key":"10.1016\/j.hrthm.2026.10.008_bib26","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.124.012732","article-title":"Characterization and clinical significance of hemolysis after pulsed field ablation for atrial fibrillation: results of a multicenter analysis","volume":"17","author":"Popa","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.hrthm.2026.10.008_bib27","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1016\/j.jacep.2024.05.001","article-title":"Periprocedural intravascular hemolysis during atrial fibrillation ablation: a comparison of pulsed field with radiofrequency ablation","volume":"10","author":"Osmancik","year":"2024","journal-title":"JACC Clin Electrophysiol"}],"container-title":["Heart Rhythm"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126028699?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1547527126028699?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T02:06:20Z","timestamp":1793325980000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1547527126028699"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":27,"alternative-id":["S1547527126028699"],"URL":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.10.008","relation":{},"ISSN":["1547-5271"],"issn-type":[{"value":"1547-5271","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Pulmonary Vein Isolation With Contact-Force-Sensing Large-Tip Focal Pulsed Field Ablation Catheter With 3D Mapping for Paroxysmal Atrial Fibrillation: Omny-IRE 12-month Results","name":"articletitle","label":"Article Title"},{"value":"Heart Rhythm","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.hrthm.2026.10.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Heart Rhythm Society.","name":"copyright","label":"Copyright"}]}}