{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T13:57:40Z","timestamp":1781272660033,"version":"3.54.1"},"reference-count":26,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,9,26]],"date-time":"2024-09-26T00:00:00Z","timestamp":1727308800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["igiejournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["iGIE"],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1016\/j.igie.2024.09.007","type":"journal-article","created":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T19:36:44Z","timestamp":1727811404000},"page":"527-532.e2","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Efficacy and safety of over-the-scope endoscopic suturing device for closure of defects after endoscopic submucosal dissection: a\u00a0systematic review and meta-analysis"],"prefix":"10.1016","volume":"3","author":[{"given":"Tahne","family":"Vongsavath","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyaw Min","family":"Tun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Syed Mohsin","family":"Saghir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay","family":"Bapaye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renuka","family":"Verma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun-Han","family":"Lo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmad","family":"Gill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Banreet Singh","family":"Dhindsa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saurabh","family":"Chandan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas G.","family":"Adler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.igie.2024.09.007_bib1","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.cgh.2018.07.041","article-title":"AGA Institute clinical practice update: endoscopic submucosal dissection in the United States","volume":"17","author":"Draganov","year":"2019","journal-title":"Clin Gastroenterol Hepatol"},{"key":"10.1016\/j.igie.2024.09.007_bib2","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1055\/s-0029-1215053","article-title":"Meta-analysis of endoscopic submucosal dissection versus endoscopic mucosal resection for tumors of the gastrointestinal tract","volume":"41","author":"Cao","year":"2009","journal-title":"Endoscopy"},{"key":"10.1016\/j.igie.2024.09.007_bib3","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1016\/j.gie.2014.07.034","article-title":"Efficacy and adverse events of EMR and endoscopic submucosal dissection for the treatment of colon neoplasms: a meta-analysis of studies comparing EMR and endoscopic submucosal dissection","volume":"81","author":"Fujiya","year":"2015","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib4","doi-asserted-by":"crossref","first-page":"17","DOI":"10.4253\/wjge.v12.i1.17","article-title":"Efficacy of mucosa-submucosa clip closure method after gastric endoscopic submucosal dissection","volume":"12","author":"Kinoshita","year":"2020","journal-title":"World J Gastrointest Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib5","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.gie.2023.07.046","article-title":"Randomized trial of gastric and colorectal endoscopic submucosal dissection defect closure comparing a novel through-the-scope suturing system with an over-the-scope suturing system (with video)","volume":"99","author":"Agnihotri","year":"2024","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib6","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.giec.2019.08.004","article-title":"The development of the OverStitch system and its potentials","volume":"30","author":"Kantsevoy","year":"2020","journal-title":"Gastrointest Endosc Clin N Am"},{"key":"10.1016\/j.igie.2024.09.007_bib7","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1080\/17434440.2022.2019579","article-title":"OverStitch Sx endoscopic suturing system in minimally invasive endoscopic procedures: overview of its safety and efficacy and comparison to OverStitchTM","volume":"19","author":"Keihanian","year":"2022","journal-title":"Expert Rev Med Devices"},{"key":"10.1016\/j.igie.2024.09.007_bib8","doi-asserted-by":"crossref","first-page":"359","DOI":"10.2147\/CLEP.S66677","article-title":"Quality assessment of observational studies in a drug-safety systematic review, comparison of two tools: the Newcastle-Ottawa Scale and the RTI item bank","volume":"6","author":"Margulis","year":"2014","journal-title":"Clin Epidemiol"},{"key":"10.1016\/j.igie.2024.09.007_bib9","article-title":"RoB 2: a revised tool for assessing risk of bias in randomised trials","volume":"366","author":"Sterne","year":"2019","journal-title":"BMJ"},{"key":"10.1016\/j.igie.2024.09.007_bib10","doi-asserted-by":"crossref","DOI":"10.1016\/j.gie.2021.03.414","article-title":"Outcomes of endoscopic suturing following endoscopic submucosal dissection [abstract]","volume":"93","author":"Ali","year":"2021","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib11","first-page":"eP031","article-title":"OverStitch suture of parietal defects after ESD and EFTR is feasible, safe, and reduce the need for hospitalization","volume":"54","author":"Grande","year":"2022","journal-title":"Endoscopy"},{"key":"10.1016\/j.igie.2024.09.007_bib12","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.vgie.2019.04.018","article-title":"Endoscopic suturing for closure of endoscopic submucosal dissection defects","volume":"4","author":"Han","year":"2019","journal-title":"VideoGIE"},{"key":"10.1016\/j.igie.2024.09.007_bib13","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/j.gie.2013.10.051","article-title":"Endoscopic suturing closure of large mucosal defects after endoscopic submucosal dissection is technically feasible, fast, and eliminates the need for hospitalization (with videos)","volume":"79","author":"Kantsevoy","year":"2014","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib14","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.gie.2023.04.006","article-title":"Safety and efficacy of a novel suturing device for closure of large defects after endoscopic submucosal dissection (with video)","volume":"98","author":"Keihanian","year":"2023","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib15","doi-asserted-by":"crossref","first-page":"AB267","DOI":"10.1016\/j.gie.2018.04.1575","article-title":"Endoscopic suturing of mucosal defects after endoscopic submucosal dissection (ESD) results in no delayed bleeding or perforation [abstract]","volume":"87","author":"Ramay","year":"2018","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib16","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.gie.2009.10.027","article-title":"A\u00a0lexicon for endoscopic adverse events: report of an ASGE workshop","volume":"71","author":"Cotton","year":"2010","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib17","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1159\/000518892","article-title":"What\u2019s new with endoscopic treatments for early gastric cancer in the \"post-ESD era\"","volume":"103","author":"Goto","year":"2022","journal-title":"Digestion"},{"key":"10.1016\/j.igie.2024.09.007_bib18","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.giec.2019.08.010","article-title":"The use of the OverStitch to close perforations and fistulas","volume":"30","author":"Ge","year":"2020","journal-title":"Gastrointest Endosc Clin N Am"},{"key":"10.1016\/j.igie.2024.09.007_bib19","doi-asserted-by":"crossref","first-page":"67","DOI":"10.5152\/DiagnIntervEndosc.2023.23092","article-title":"Real-world experience with the OverStitch endoscopic suturing system: insights from the FDA Manufacturer and User Facility Device Experience (MAUDE) database","volume":"2","author":"Frost","year":"2023","journal-title":"Diagn Interv Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib20","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1016\/j.gie.2022.06.004","article-title":"Endoscopic suturing for GI applications: initial results from a prospective multicenter European registry","volume":"96","author":"Maselli","year":"2022","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib21","series-title":"StatPearls. Treasure Island, FL","article-title":"Anatomy, Thorax, Esophagus","author":"Chaudhry","year":"2024"},{"key":"10.1016\/j.igie.2024.09.007_bib22","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1007\/s00383-017-4112-5","article-title":"Sensory innervation of the anal canal and anorectal line in Hirschsprung's disease: histological evidence from mouse models","volume":"33","author":"Takeda","year":"2017","journal-title":"Pediatr Surg Int"},{"issue":"Suppl 1","key":"10.1016\/j.igie.2024.09.007_bib23","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/den.13388","article-title":"Management of adverse events related to endoscopic resection of upper gastrointestinal neoplasms: review of the literature and recommendations from experts","volume":"31","author":"Yamamoto","year":"2019","journal-title":"Dig Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib24","doi-asserted-by":"crossref","first-page":"2779","DOI":"10.1007\/s00464-015-4551-9","article-title":"Prevention of esophageal stricture after endoscopic submucosal dissection: a systematic review and meta-analysis","volume":"30","author":"Oliveira","year":"2016","journal-title":"Surg Endosc"},{"key":"10.1016\/j.igie.2024.09.007_bib25","series-title":"Research in Medical and Biological Sciences From Planning and Preparation to Grant Application and Publication","first-page":"431","author":"Fagerland","year":"2015"},{"issue":"Suppl 1","key":"10.1016\/j.igie.2024.09.007_bib26","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1590\/0102-6720201600s10023","article-title":"Endoscopic sleeve gastroplasty\u2014minimally invasive therapy for primary obesity treatment","volume":"29","author":"Galv\u00e3o-Neto","year":"2016","journal-title":"Arq Bras Cir Dig"}],"container-title":["iGIE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2949708624001328?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2949708624001328?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:55:03Z","timestamp":1760147703000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2949708624001328"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["S2949708624001328"],"URL":"https:\/\/doi.org\/10.1016\/j.igie.2024.09.007","relation":{},"ISSN":["2949-7086"],"issn-type":[{"value":"2949-7086","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Efficacy and safety of over-the-scope endoscopic suturing device for closure of defects after endoscopic submucosal dissection: a\u00a0systematic review and meta-analysis","name":"articletitle","label":"Article Title"},{"value":"iGIE","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.igie.2024.09.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}