{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T03:01:33Z","timestamp":1782183693461,"version":"3.54.5"},"reference-count":15,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2017,11,1]],"date-time":"2017-11-01T00:00:00Z","timestamp":1509494400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,10,6]],"date-time":"2017-10-06T00:00:00Z","timestamp":1507248000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Indian Heart Journal"],"published-print":{"date-parts":[[2017,11]]},"DOI":"10.1016\/j.ihj.2017.10.004","type":"journal-article","created":{"date-parts":[[2017,10,12]],"date-time":"2017-10-12T07:47:34Z","timestamp":1507794454000},"page":"687-689","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Bioresorbable scaffold -fourth revolution or failed revolution: Is low scaffold strut thickness the wrong target?"],"prefix":"10.1016","volume":"69","author":[{"given":"Sundeep","family":"Mishra","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ihj.2017.10.004_bib0005","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.ihj.2017.01.006","article-title":"A fresh look at bioresorbable scaffold technology: intuition pumps","volume":"60","author":"Mishra","year":"2017","journal-title":"Ind Heart J"},{"issue":"1","key":"10.1016\/j.ihj.2017.10.004_bib0010","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jcin.2015.09.024","article-title":"Scaffold Thrombosis After Percutaneous Coronary Intervention With ABSORB Bioresorbable Vascular Scaffold","volume":"9","author":"Lipinski","year":"2016","journal-title":"JACC Cardiovasc Interventions"},{"key":"10.1016\/j.ihj.2017.10.004_bib0015","doi-asserted-by":"crossref","first-page":"1901","DOI":"10.1016\/j.jacc.2015.08.853","article-title":"Very late scaffold thrombosis: intracoronary imaging and histopathological and spectroscopic findings","volume":"66","author":"R\u00e4ber","year":"2015","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ihj.2017.10.004_bib0020","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1161\/CIRCINTERVENTIONS.113.000990","article-title":"Long-term safety of an everolimus-eluting bioresorbable vascular scaffold and the cobalt-chromium XIENCE V stent in a porcine coronary artery model","volume":"7","author":"Otsuka","year":"2014","journal-title":"Circ Cardiovasc Interventions"},{"key":"10.1016\/j.ihj.2017.10.004_bib0025","doi-asserted-by":"crossref","first-page":"e002518","DOI":"10.1161\/CIRCINTERVENTIONS.114.002518","article-title":"Optical Coherence tomography findings in bioresorbable vascular scaffolds thrombosis","volume":"8","author":"Cuculi","year":"2015","journal-title":"Circ Cardiovasc Interventions"},{"key":"10.1016\/j.ihj.2017.10.004_bib0030","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1097\/MCA.0000000000000134","article-title":"Peri-strut low-intensity areas in optical coherence tomography correlate with peri-strut inflammation and neointimal proliferation: an in-vivo correlation study in the familial hypercholesterolemic coronary swine model of in-stent restenosis","volume":"25","author":"Tellez","year":"2014","journal-title":"Coron Artery Dis"},{"key":"10.1016\/j.ihj.2017.10.004_bib0035","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1016\/j.jacc.2015.11.062","article-title":"Mechanisms of late and very late bioresorbable vascular scaffold thrombosis: is it only about flow?","volume":"67","author":"Arroyo","year":"2016","journal-title":"J Am Coll Cardiol"},{"issue":"June (11)","key":"10.1016\/j.ihj.2017.10.004_bib0040","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1016\/j.jcin.2017.04.006","article-title":"Bioresorbable scaffolds: polymer troubleshooting or simply not good enough?","volume":"10","author":"Waksman","year":"2017","journal-title":"JACC Cardiovasc Interventions"},{"key":"10.1016\/j.ihj.2017.10.004_bib0045","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1016\/j.jcin.2017.03.015","article-title":"Randomized comparison of absorb bioresorbable vascular scaffold and mirage microfiber sirolimus-eluting scaffold using multimodality imaging","volume":"10","author":"Tenekecioglu","year":"2017","journal-title":"J Am Coll Cardiol Intv"},{"key":"10.1016\/j.ihj.2017.10.004_bib0050","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1016\/j.jcin.2014.07.004","article-title":"Immediate, acute and subacute thrombosis due to incomplete expansion of bioresorbable scaffolds","volume":"7","author":"Gori","year":"2014","journal-title":"J Am Coll Cardiol Interventions"},{"key":"10.1016\/j.ihj.2017.10.004_bib0055","doi-asserted-by":"crossref","first-page":"2110","DOI":"10.4244\/EIJ-D-16-00974","article-title":"Predilation, sizing and post-dilation scoring in patients undergoing everolimus-eluting bioresorbable scaffold implantation for prediction of cardiac adverse events: development and internal validation of the PSP score","volume":"12","author":"Ortega-Paz","year":"2017","journal-title":"EuroIntervention"},{"issue":"September (18)","key":"10.1016\/j.ihj.2017.10.004_bib0060","doi-asserted-by":"crossref","first-page":"1839","DOI":"10.1016\/j.jcin.2017.06.009","article-title":"Fantom bioresorbable scaffold: verse, but not yet chorus (an incomplete composition)","volume":"10","author":"Ellis","year":"2017","journal-title":"JACC Cardiovasc Interventions"},{"key":"10.1016\/j.ihj.2017.10.004_bib0065","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.ihj.2016.08.012","article-title":"Are all stents equal-need for scoring system to evaluate stents?","volume":"68","author":"Mishra","year":"2016","journal-title":"Indian Heart J"},{"key":"10.1016\/j.ihj.2017.10.004_bib0070","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.4244\/EIJY14M07_11","article-title":"Percutaneous coronary intervention with everolimus- eluting bioresorbable vascular scaffolds in routine clinical practice: early and midterm outcomes from the European multicentre GHOST-EU registry","volume":"10","author":"Capodanno","year":"2015","journal-title":"EuroIntervention"},{"key":"10.1016\/j.ihj.2017.10.004_bib0075","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1016\/j.jcin.2017.06.067","article-title":"Clinical, angiographic, and procedural correlates of acute, subacute, and late Absorb scaffold thrombosis","volume":"10","author":"Ellis","year":"2017","journal-title":"J Am Coll Cardiol Interventions"}],"container-title":["Indian Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0019483217308477?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0019483217308477?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,10,4]],"date-time":"2019-10-04T14:30:08Z","timestamp":1570199408000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0019483217308477"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11]]},"references-count":15,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017,11]]}},"alternative-id":["S0019483217308477"],"URL":"https:\/\/doi.org\/10.1016\/j.ihj.2017.10.004","relation":{},"ISSN":["0019-4832"],"issn-type":[{"value":"0019-4832","type":"print"}],"subject":[],"published":{"date-parts":[[2017,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Bioresorbable scaffold -fourth revolution or failed revolution: Is low scaffold strut thickness the wrong target?","name":"articletitle","label":"Article Title"},{"value":"Indian Heart Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ihj.2017.10.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Cardiological Society of India. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}