{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,18]],"date-time":"2025-09-18T10:13:04Z","timestamp":1758190384804,"version":"3.44.0"},"reference-count":22,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,10,29]],"date-time":"2021-10-29T00:00:00Z","timestamp":1635465600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Indian Heart Journal"],"published-print":{"date-parts":[[2021,11]]},"DOI":"10.1016\/j.ihj.2021.10.012","type":"journal-article","created":{"date-parts":[[2021,10,29]],"date-time":"2021-10-29T04:01:27Z","timestamp":1635480087000},"page":"718-724","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Pulmonary vein isolation for atrial fibrillation: Does ablation technique influence outcome?"],"prefix":"10.1016","volume":"73","author":[{"given":"S.A.","family":"Reddy","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.L.","family":"Nethercott","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.V.","family":"Khialani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.S.","family":"Virdee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"10","key":"10.1016\/j.ihj.2021.10.012_bib1","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1056\/NEJM199809033391003","article-title":"Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins","volume":"339","author":"Ha\u00efssaguerre","year":"1998","journal-title":"N\u00a0Engl J Med"},{"issue":"5","key":"10.1016\/j.ihj.2021.10.012_bib2","first-page":"369","article-title":"2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary","volume":"33","author":"Calkins","year":"2017","journal-title":"J\u00a0Arrhythm"},{"issue":"17","key":"10.1016\/j.ihj.2021.10.012_bib3","first-page":"1303","volume":"38","author":"Arbelo","year":"2017","journal-title":"Eur Heart J"},{"issue":"9","key":"10.1016\/j.ihj.2021.10.012_bib4","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1111\/j.1540-8167.2011.02050.x","article-title":"Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon","volume":"22","author":"Gaita","year":"2011","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"issue":"1","key":"10.1016\/j.ihj.2021.10.012_bib5","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s12471-016-0907-6","article-title":"Effective contact and outcome after pulmonary vein isolation in novel circular multi-electrode atrial fibrillation ablation","volume":"25","author":"Gal","year":"2017","journal-title":"Neth Heart J"},{"issue":"9","key":"10.1016\/j.ihj.2021.10.012_bib6","doi-asserted-by":"crossref","first-page":"1162","DOI":"10.1111\/j.1540-8159.2012.03436.x","article-title":"The biophysics and biomechanics of cryoballoon ablation","volume":"35","author":"Andrade","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"issue":"7","key":"10.1016\/j.ihj.2021.10.012_bib7","article-title":"Incidence and predictors of complications during cryoballoon pulmonary vein isolation for atrial fibrillation","volume":"5","author":"Guhl","year":"2016","journal-title":"J\u00a0Am Heart Assoc"},{"issue":"9","key":"10.1016\/j.ihj.2021.10.012_bib8","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1111\/pace.12663","article-title":"One year incidence of atrial septal defect after PV isolation: a comparison between conventional radiofrequency and cryoballoon ablation","volume":"38","author":"Mugnai","year":"2015","journal-title":"Pacing Clin Electrophysiol"},{"issue":"2","key":"10.1016\/j.ihj.2021.10.012_bib9","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1007\/s10840-018-0352-0","article-title":"High rate of persistent iatrogenic atrial septal defect after single transseptal puncture for cryoballoon pulmonary vein isolation","volume":"52","author":"Linhart","year":"2018","journal-title":"J\u00a0Intervent Card Electrophysiol"},{"issue":"7","key":"10.1016\/j.ihj.2021.10.012_bib10","doi-asserted-by":"crossref","first-page":"1476","DOI":"10.1016\/j.hrthm.2015.04.001","article-title":"Incidence and characteristics of complications in the setting of second-generation cryoballoon ablation: a large single-center study of 500 consecutive patients","volume":"12","author":"Mugnai","year":"2015","journal-title":"Heart Rhythm"},{"issue":"5","key":"10.1016\/j.ihj.2021.10.012_bib11","first-page":"1282","article-title":"Contact force and atrial fibrillation ablation","volume":"8","author":"Ullah","year":"2016","journal-title":"J\u00a0Atr Fibrillation"},{"issue":"11","key":"10.1016\/j.ihj.2021.10.012_bib12","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1093\/europace\/eut104","article-title":"Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: a randomized controlled study comparing the clinical outcome and safety; the AF-COR study","volume":"15","author":"Malmborg","year":"2013","journal-title":"Europace"},{"issue":"9","key":"10.1016\/j.ihj.2021.10.012_bib13","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1111\/j.1540-8159.2010.02807.x","article-title":"Catheter ablation for paroxysmal atrial fibrillation: a randomized comparison between multielectrode catheter and point-by-point ablation","volume":"33","author":"Bulava","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"issue":"9","key":"10.1016\/j.ihj.2021.10.012_bib14","doi-asserted-by":"crossref","first-page":"1383","DOI":"10.1016\/j.hrthm.2011.03.051","article-title":"Randomized study comparing duty-cycled bipolar and unipolar radiofrequency with point-by-point ablation in pulmonary vein isolation","volume":"8","author":"Bittner","year":"2011","journal-title":"Heart Rhythm"},{"issue":"3","key":"10.1016\/j.ihj.2021.10.012_bib15","first-page":"377","article-title":"Meta-analysis of contemporary atrial fibrillation ablation strategies","volume":"2","author":"Kabunga","year":"2016","journal-title":"JACC (J Am Coll Cardiol): Clinical Electrophysiology"},{"key":"10.1016\/j.ihj.2021.10.012_bib16","doi-asserted-by":"crossref","first-page":"1812","DOI":"10.1056\/NEJMoa1408288","article-title":"For the STAR AF II investigators. Approaches to catheter ablation for persistent atrial fibrillation","volume":"372","author":"Verma","year":"2015","journal-title":"N\u00a0Engl J Med"},{"issue":"3","key":"10.1016\/j.ihj.2021.10.012_bib17","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1007\/s10840-016-0120-y","article-title":"Novel usage of the cryoballoon catheter to achieve large area atrial substrate modification in persistent and long-standing persistent atrial fibrillation","volume":"46","author":"Su","year":"2016","journal-title":"J\u00a0Intervent Card Electrophysiol"},{"issue":"4","key":"10.1016\/j.ihj.2021.10.012_bib18","first-page":"529","article-title":"Cryoballoon isolation of the superior vena cava","volume":"2","author":"Gonna","year":"2016","journal-title":"J\u00a0Am Coll Cardiol EP"},{"issue":"10","key":"10.1016\/j.ihj.2021.10.012_bib19","doi-asserted-by":"crossref","first-page":"1433","DOI":"10.1093\/europace\/eus086","article-title":"Safety of pulmonary vein isolation and left atrial complex fractionated atrial electrograms ablation for atrial fibrillation with phased radiofrequency energy and multi-electrode catheters","volume":"14","author":"Mulder","year":"2012","journal-title":"Europace"},{"issue":"3","key":"10.1016\/j.ihj.2021.10.012_bib20","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/j.jacc.2019.04.021","article-title":"Pulsed field ablation for pulmonary vein isolation in atrial fibrillation","volume":"74","author":"Reddy","year":"2019","journal-title":"J\u00a0Am Coll Cardiol"},{"issue":"4","key":"10.1016\/j.ihj.2021.10.012_bib21","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.118.007090","article-title":"Expandable lattice electrode ablation catheter: a novel radiofrequency platform allowing high current at low density for rapid, titratable, and durable lesions","volume":"12","author":"Barkagan","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"6","key":"10.1016\/j.ihj.2021.10.012_bib22","first-page":"1040","article-title":"Monitoring atrial fibrillation after catheter ablation","volume":"6","author":"Forleo","year":"2014","journal-title":"J\u00a0Atr Fibrillation"}],"container-title":["Indian Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0019483221002315?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0019483221002315?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T03:54:18Z","timestamp":1758081258000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0019483221002315"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11]]},"references-count":22,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["S0019483221002315"],"URL":"https:\/\/doi.org\/10.1016\/j.ihj.2021.10.012","relation":{},"ISSN":["0019-4832"],"issn-type":[{"type":"print","value":"0019-4832"}],"subject":[],"published":{"date-parts":[[2021,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Pulmonary vein isolation for atrial fibrillation: Does ablation technique influence outcome?","name":"articletitle","label":"Article Title"},{"value":"Indian Heart Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ihj.2021.10.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Cardiological Society of India. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}