{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T21:17:24Z","timestamp":1784063844863,"version":"3.55.0"},"reference-count":24,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,4,9]],"date-time":"2022-04-09T00:00:00Z","timestamp":1649462400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Indian Heart Journal"],"published-print":{"date-parts":[[2022,5]]},"DOI":"10.1016\/j.ihj.2022.04.001","type":"journal-article","created":{"date-parts":[[2022,4,12]],"date-time":"2022-04-12T13:02:17Z","timestamp":1649768537000},"page":"201-205","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Minimizing scattered radiation dose in cardiac catheterization laboratory during interventional procedures using lead free drape \u2013 MILD study"],"prefix":"10.1016","volume":"74","author":[{"given":"Keshavamurthy Ganapathy","family":"Bhat","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9477-6728","authenticated-orcid":false,"given":"Vivek Singh","family":"Guleria","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manish","family":"Singla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vijay","family":"Bohra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ratheesh","family":"Kumar J","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prashant","family":"Bharadwaj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajat","family":"Datta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pradeep Kumar","family":"Hasija","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.ihj.2022.04.001_bib1","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ahj.2008.08.009","article-title":"Cancer risk from professional exposure in staff working in cardiac catheterization laboratory: insights from the National Research Council's Biological Effects of Ionizing Radiation VII Report","volume":"157","author":"Venneri","year":"2009","journal-title":"Am Heart J"},{"issue":"5","key":"10.1016\/j.ihj.2022.04.001_bib2","doi-asserted-by":"crossref","first-page":"1843","DOI":"10.1016\/j.ijcard.2012.04.124","article-title":"Interventional cardiologists and risk of radiation-induced cataract: results of a French multicenter observational study","volume":"167","author":"Jacob","year":"2013","journal-title":"Int J Cardiol"},{"issue":"1","key":"10.1016\/j.ihj.2022.04.001_bib3","doi-asserted-by":"crossref","first-page":"3","DOI":"10.2214\/ajr.177.1.1770003","article-title":"Skin injuries from fluoroscopically guided procedures: part 1, characteristics of radiation injury","volume":"177","author":"Koenig","year":"2001","journal-title":"AJR Am J Roentgenol"},{"issue":"9","key":"10.1016\/j.ihj.2022.04.001_bib4","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.4244\/EIJV7I9A172","article-title":"Brain tumours among interventional cardiologists: a cause for alarm? Report of four new cases from two cities and a review of the literature","volume":"7","author":"Roguin","year":"2012","journal-title":"EuroIntervention"},{"issue":"9","key":"10.1016\/j.ihj.2022.04.001_bib5","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1016\/j.amjcard.2012.12.060","article-title":"Brain and neck tumors among physicians performing interventional procedures","volume":"111","author":"Roguin","year":"2013","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ihj.2022.04.001_bib6","series-title":"Radiation Exposure in the Cath Lab - Safety and Precautions","author":"Raza","year":"2006"},{"issue":"6","key":"10.1016\/j.ihj.2022.04.001_bib7","first-page":"826","article-title":"Risk for radiation-induced cataract for staff in interventional cardiology: is there reason for concern?","volume":"76","author":"Ciraj-Bjelac","year":"2010","journal-title":"Cathet Cardiovasc Interv"},{"issue":"1\u20132","key":"10.1016\/j.ihj.2022.04.001_bib8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.icrp.2012.02.001","article-title":"ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context","volume":"41","author":"Stewart","year":"2012","journal-title":"Ann ICRP"},{"issue":"4","key":"10.1016\/j.ihj.2022.04.001_bib9","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.115.003273","article-title":"Occupational health risks in cardiac catheterization laboratory workers","volume":"9","author":"Andreassi","year":"2016","journal-title":"Circ Cardiovasc Interv"},{"issue":"5","key":"10.1016\/j.ihj.2022.04.001_bib10","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.ihj.2020.07.018","article-title":"National interventional council data for the year 2018-India","volume":"72","author":"Arramraju","year":"2020","journal-title":"Indian Heart J"},{"issue":"12","key":"10.1016\/j.ihj.2022.04.001_bib11","doi-asserted-by":"crossref","first-page":"1769","DOI":"10.1093\/europace\/euq356","article-title":"Reducing operator radiation exposure during cardiac resynchronization therapy","volume":"12","author":"Brambilla","year":"2010","journal-title":"Europace"},{"issue":"10","key":"10.1016\/j.ihj.2022.04.001_bib12","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.1016\/j.amjcard.2011.06.061","article-title":"Efficacy of the RADPAD protective drape during real world complex percutaneous coronary intervention procedures","volume":"108","author":"Murphy","year":"2011","journal-title":"Am J Cardiol"},{"issue":"1","key":"10.1016\/j.ihj.2022.04.001_bib13","doi-asserted-by":"crossref","first-page":"153","DOI":"10.2214\/ajr.178.1.1780153","article-title":"Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists","volume":"178","author":"King","year":"2002","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.ihj.2022.04.001_bib14","doi-asserted-by":"crossref","first-page":"109245","DOI":"10.1016\/j.ejrad.2020.109245","article-title":"Scatter radiation reduction with a radiation-absorbing pad in interventional radiology examinations","volume":"132","author":"Koenig","year":"2020","journal-title":"Eur J Radiol"},{"issue":"Suppl 3","key":"10.1016\/j.ihj.2022.04.001_bib15","doi-asserted-by":"crossref","first-page":"S265","DOI":"10.1016\/j.ihj.2018.03.008","article-title":"Efficacy of RADPAD protection drape in reducing radiation exposure in the catheterization laboratory-First Indian study","volume":"70","author":"Shah","year":"2018","journal-title":"Indian Heart J"},{"issue":"2","key":"10.1016\/j.ihj.2022.04.001_bib16","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.ijcard.2014.08.144","article-title":"Comparison of fluoro and cine angiographic modes in coronary stenting procedure: a preliminary feasibility study","volume":"177","author":"Olcay","year":"2014","journal-title":"Int J Cardiol"},{"issue":"4","key":"10.1016\/j.ihj.2022.04.001_bib17","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1016\/j.jcin.2014.12.233","article-title":"Subclinical carotid atherosclerosis and early vascular aging from long-term low-dose ionizing radiation exposure: a genetic, telomere, and vascular ultrasound study in cardiac catheterization laboratory staff","volume":"8","author":"Andreassi","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"issue":"3","key":"10.1016\/j.ihj.2022.04.001_bib18","first-page":"186","article-title":"Review of radiation safety in the cardiac catheterization laboratory","volume":"25","author":"Johnson","year":"1992","journal-title":"Cathet Cardiovasc Diagn"},{"issue":"1","key":"10.1016\/j.ihj.2022.04.001_bib19","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/01.HP.0000356672.44380.b7","article-title":"NCRP Report No. 160, Ionizing Radiation Exposure of the Population of the United States, medical exposure--are we doing less with more, and is there a role for health physicists?","volume":"97","author":"Schauer","year":"2009","journal-title":"Health Phys"},{"issue":"1","key":"10.1016\/j.ihj.2022.04.001_bib20","doi-asserted-by":"crossref","first-page":"7104","DOI":"10.1038\/s41598-020-62794-2","article-title":"Occupational radiation exposure in femoral artery approach is higher than radial artery approach during coronary angiography or percutaneous coronary intervention","volume":"10","author":"Kim","year":"2020","journal-title":"Sci Rep"},{"issue":"8","key":"10.1016\/j.ihj.2022.04.001_bib21","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.117.005689","article-title":"Radiation exposure in cardiac catheterization: operator behavior matters","volume":"10","author":"Kobayashi","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"issue":"4","key":"10.1016\/j.ihj.2022.04.001_bib22","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1007\/s00059-017-4560-7","article-title":"Efficacy of RADPAD protective drape during coronary angiography","volume":"43","author":"Kherad","year":"2018","journal-title":"Herz"},{"issue":"11","key":"10.1016\/j.ihj.2022.04.001_bib23","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.117.006058","article-title":"Efficacy of the RADPAD protection drape in reducing operators' radiation exposure in the catheterization laboratory: a sham-controlled randomized trial","volume":"10","author":"Vlastra","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"issue":"3","key":"10.1016\/j.ihj.2022.04.001_bib24","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.ejvs.2013.12.008","article-title":"Editor's choice--Use of disposable radiation-absorbing surgical drapes results in significant dose reduction during EVAR procedures","volume":"47","author":"Kloeze","year":"2014","journal-title":"Eur J Vasc Endovasc Surg"}],"container-title":["Indian Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0019483222000621?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0019483222000621?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T03:55:50Z","timestamp":1758081350000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0019483222000621"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,5]]}},"alternative-id":["S0019483222000621"],"URL":"https:\/\/doi.org\/10.1016\/j.ihj.2022.04.001","relation":{},"ISSN":["0019-4832"],"issn-type":[{"value":"0019-4832","type":"print"}],"subject":[],"published":{"date-parts":[[2022,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Minimizing scattered radiation dose in cardiac catheterization laboratory during interventional procedures using lead free drape \u2013 MILD study","name":"articletitle","label":"Article Title"},{"value":"Indian Heart Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ihj.2022.04.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 Published by Elsevier, a division of RELX India, Pvt. Ltd on behalf of Cardiological Society of India.","name":"copyright","label":"Copyright"}]}}